Rule 1256a. (1) A scaffold platform shall not be placed higher than the second
highest rung or step of the ladder supporting the platform.
(2) A ladder used in conjunction with a step, platform, and trestle ladder scaffold
shall comply with the pertinent requirements of Construction Safety Standard Part 11.
“Fixed and Portable Ladders,” as referenced in R 408.41201, except that job-made
ladders shall not be used to support a step, platform, or trestle scaffold.
(3) A ladder used to support a step, platform, and trestle ladder scaffold shall be
placed, fastened, or equipped with a device to prevent slipping.