R 408.41563
R 408.41563 Bridge tower construction personnel hoists.
Cite as Mich. Admin. Code R 408.41563
Rule 1563. (1) A personnel hoist that is used in bridge tower construction shall be approved
by a registered professional engineer and installed in accordance with R 408.41560(2).
(2) When a hoist tower is not enclosed, the car or hoist platform shall be totally enclosed or
caged on all sides for the full height between the floor and the overhead protective covering
with not less than 3/4-inch mesh of no. 14 U.S. gauge wire or equivalent. The hoist car
enclosure shall include the required gates for loading and unloading.
(3) An employer shall ensure that hoists are inspected for defects, serviced, and maintained
on a weekly basis, and repaired as necessary. If the hoisting equipment is exposed to winds of
more than 35 miles per hour, authorized personnel must inspect and repair the hoisting
equipment if necessary before reuse.