R 408.41950
R 408.41950 Powder-actuated tool defects and misfires.
Cite as Mich. Admin. Code R 408.41950
Rule 1950. In case of a misfire, the operator shall hold the powder-actuated
tool in the operating position for not less than 30 seconds. The operator shall then
try to operate the tool a second time.The operator shall wait another 30 seconds,
holding the tool in the operating position, then the operator shall proceed to
remove the explosive load in strict accordance with the manufacturer's instructions.
Misfired cartridges should be placed carefully in a metal container filled with water and
returned to the supervisor for disposal.