R 299.2304
R 299.2304 Definitions; S to Z.
Cite as Mich. Admin. Code R 299.2304
Rule 2304. As used in these rules:
(a) "Safety equipment" means, at a minimum, all of the following items:
(i) First aid kits.
(ii) Stretchers.
(iii) Blankets.
(iv) Portable dry chemical fire extinguishers.
(v) Ropes.
(vi) Flare guns and flares.
(vii) Battery-operated lanterns.
(viii) Portable electronic hydrogen sulfide detectors.
(ix) Warning signs that have the word "danger" or "caution" followed by the words
"poison gas."
(x) Two copies of the owner's contingency plan.
(xi) Not less than 2 portable, self-contained, pressure-demand breathing apparatus that
have a 30-minute air supply.
(xii) A supply of compressed breathable air or oxygen that is sufficient to recharge each
self-contained breathing apparatus at least once.
(b) "Shut-in" means an action by an owner or permittee to close down an active well
temporarily.
(c) "Site restoration" means all of the following:
(i) The filling and leveling of all cellars, pits, and excavations.
(ii) The removal or elimination of all debris.
(iii) The elimination of all conditions that may create a fire or pollution hazard.
(iv) The minimization of erosion.
(v) The restoration of the well site as nearly as practicable to the original land contour or
to a condition approved by the supervisor of mineral wells.
(d) "Solution mining" means the process of injecting fluid into a well to dissolve rock
salt or other readily soluble rock or mineral, and the production of the resulting artificial
brine.
(e) "Stored product" means any substance except liquid hydrocarbons, liquified petroleum
gas, or dry natural gas which is injected into an underground storage cavity with the intent
to remove the substance from the underground storage cavity at some future time. Stored
product does not include water or other solvents injected into a cavity or well during
solution mining to form an artificial brine.
(f) "Structure used for public or private occupancy" means a residential dwelling or place
of business, place of worship, school, hospital, government building, or other building
where people are expected to be present at least 4 hours per day.
(g) "Substantially modify" means any of the following:
(i) To permanently reroute above-ground facility piping outside of an existing secondary
containment area.
(ii) To add vessels at a surface facility or well having no secondary containment on the
effective date of these rules.
(iii) To add a vessel at a surface facility having secondary containment when the addition
of the vessel would increase the total volume of the vessels to more than the capacity of
the diked area required in R 299.2446(c). Substantially modify does not include routine
maintenance or emergency repairs at a wellhead or surface facility.
(h) "Surface casing" means the casing string or strings used primarily for protecting fresh
water or mineralized water resources from potential contamination during the drilling and
operation of a well.
(i) "Surface facility" means the area in the vicinity of a well subject to this part where
produced brine, waste products or stored products are held temporarily before
transportation, disposal, or storage, and the surface equipment necessary for handling,
disposing, or storing the liquids. Surface facility does not include any of the following:
(i) Surface equipment subject to a permit under Part 111 of the act.
(ii) Surface equipment within the perimeter of a manufacturing plant if the surface
equipment is subject to secondary containment and spill response and reporting
requirements under another part of the act.
(iii) A pipeline connecting a well directly to a manufacturing plant.
(iv) A well annulus monitoring system.
(j) "Surface water" means a body of water, and the associated sediments, which has a top
surface that is exposed to the atmosphere and which is not solely for wastewater
conveyance, treatment, or control. Surface water may be any of the following:
(i) A Great Lake or its connecting waters.
(ii) An inland lake or pond.
(iii) A river or stream, including intermittent streams.
(iv) An impoundment.
(v) An open drain.
(vi) A wetland.
(k) "Underground source of drinking water" means an aquifer or any portion of an aquifer
which does either of the following:
(i) Supplies any public or private water system.
(ii) Contains a sufficient quantity of groundwater to supply a public or private water
system; and includes either of the following:
(A) Currently supplies drinking water for human consumption.
(B) Contains fewer than 11,000 milligrams per liter total dissolved solids.
(l) "Well completion" means the time when a well has been tested and found to be
incapable of being put to the use for which it was intended and has been plugged or has
been found capable of being put to the use for which it was intended or when the well has
been equipped to perform the service for which it was intended.
(m) "Well completion operations" means work performed in a well, after the well has
been drilled to its permitted depth and the innermost string of casing has been set, including
perforating, artificial stimulation, and production testing.
(n) "Well location" means the surface location of a well.
(o) "Zoned residential" means a geographic area that was zoned by a local unit of
government before the effective date of these rules, as an area designated principally for
permanent or recreational residences.