R 299.24
R 299.24 Generic cleanup criteria for soil based on indoor inhalation of hazardous substance vapors volatilized from soil.
Cite as Mich. Admin. Code R 299.24
Rule 24. (1) Indoor inhalation of hazardous substance vapors volatilizing to indoor air
from soil shall be considered a reasonable and relevant exposure pathway only for
hazardous substances that have a Henry’s law constant greater than or equal to 0.00001
atm-m3/mole.
(2) Except as provided in subrule (1) of this rule, if any of the following conditions exist,
the generic criteria developed pursuant to this rule shall not apply and a site-specific
evaluation of indoor inhalation risks shall be conducted:
(a) There is a structure present or planned to be constructed at the facility which does not
have a concrete block or poured concrete floor and walls.
(b) There is a sump present that is not completely isolated from the surrounding soil by
its materials of construction.
(3) Soil cleanup criteria based on indoor inhalation of volatile emissions from hazardous
substances in soil shall be called soil volatilization indoor air inhalation criteria (“SVIIC”).
The SVIIC is determined by the following series of calculations, except as provided in R
299.34(3):
EQUATION FOR CARCINOGENIC EFFECTS:
building
CR
ED
EF
IURF
AIR
X
AT
TR
SVIIC
where,
SVIIC
(Soil volatilization indoor air
inhalation criterion)
= chemical-specific, ug/kg
TR
(Target risk level)
= 10-5
AT
(Averaging time)
= 25,550 days (70 years x 365
days/year)
AIR
(Adjusted inhalation rate)
= 1 (residential)
= 2 (nonresidential)
IURF
(Inhalation unit risk factor)
= chemical-specific, (ug/m3)-1
EF
(Exposure frequency)
= 350 days/year (residential)
= 245 days/year (nonresidential)
ED
(Exposure duration)
= 30 years (residential)
= 21 years (nonresidential)
CRbuilding
(Ratio of indoor air concentration
to soil concentration)
= chemical-specific,
(ug/m3)/(ug/kg)
EQUATION FOR NONCARCINOGENIC EFFECTS:
building
CR
ED
EF
ITSL
1
AT
THQ
SVIIC
where,
SVIIC
(Soil volatilization indoor air
inhalation criterion)
= chemical-specific, ug/kg
THQ
(Target hazard quotient)
= 1
AT
(Averaging time)
= 10,950 days (residential)
= 7,665 days (nonresidential)
EF
(Exposure frequency)
= 350 days/year (residential)
= 245 days/year (nonresidential)
ED
(Exposure duration)
= 30 years (residential)
= 21 years (nonresidential)
ITSL
(Initial threshold screening level)
= chemical-specific, ug/m3
CRbuilding
(Ratio of indoor air concentration
to soil concentration)
= chemical-specific,
(ug/m3)/(ug/kg)
The contaminant vapor concentration in the building indoor air is written as:
soil
source
building
CR
CR
where,
CRbuilding
(Ratio of indoor air concentration to
soil concentration)
= chemical-specific,
(ug/m3)/(ug/kg)
(Attenuation coefficient)
= chemical-specific,
Unitless
soil
source
CR
(Ratio of soil vapor concentration to
soil/source concentration)
= chemical-specific,
(ug/m3)/(ug/kg)
The vapor-phase contaminant concentration at the source for soil is written as:
a
b
d
w
3
3
6
3
b
s
soil
source
TAF
'
H
k
m
cm
10
g
kg
10
C
TAF
'
H
CR
where,
soil
source
CR
(Ratio of soil vapor concentration to
soil/source concentration)
= chemical-specific,
(ug/m3)/(ug/kg)
H’
(Dimensionless Henry’s law constant,
where H’ = HLC x 41)
= chemical-specific, unitless
HLC
(Henry’s law constant at 25 degrees
Celsius)
= chemical-specific,
(atm-m3/mol)
TAF
(Temperature adjustment factor)
= 0.5, unitless
s
C
(Uniform concentration in soil)
= 1 ug/kg
b
(Dry soil bulk density)
= 1.5 g/cm3
w
(Soil water-filled porosity)
= 0.3 cm3/cm3
d
k
(Soil-water partition coefficient)
= chemical-specific, cm3/g
(equivalent to L/kg)
For organic compounds
= Koc (cm3/g) x foc (g/g)
For inorganic compounds
= chemical-specific, cm3/g
oc
K
(Soil organic carbon partition
coefficient)
= chemical-specific, cm3/g
oc
f
(Fraction of organic carbon content of
soil)
= 0.002 g/g (0.2%)
a
(Soil air-filled porosity)
= 0.13 cm3/cm3
The intrusion rate of hazardous substance vapors into buildings is predicted using an
analytical solution which couples both diffusive and convective transport of vapors
emanating from subsurface soil into enclosed spaces. An attenuation coefficient () is
calculated that is expressed as the ratio of building indoor air concentration to the vapor-
phase concentration at the source. Values of are calculated assuming infinite source
conditions. For infinite source conditions is written as follows:
1
A
D
L
Q
exp
L
Q
A
D
L
Q
A
D
A
D
L
Q
exp
A
D
L
Q
exp
L
Q
A
D
crack
crack
crack
soil
T
soil
b
T
building
b
crack
crack
crack
soil
crack
crack
crack
soil
T
building
b
eff
v
eff
v
eff
v
where,
(Attenuation coefficient)
= unitless
eff
v
D
(Effective diffusion coefficient
through vadose zone)
= chemical-specific, cm2/s
Dcrack
(Effective diffusion coefficient
through crack)
= cm2/s, (Dcrack =
eff
v
D
, see
equation for
eff
v
D
below)
Ab
(Area of enclosed space below grade)
= 1.96E+6 cm2 (residential)
= 3.83E+6 cm2 (nonresidential)
Qbuilding
(Building ventilation rate)
= 1.51E+5 cm3/s (residential)
= 5.04E+5 cm3/s (nonresidential)
Lcrack
(Building foundation thickness)
= 15 cm
LT
(Source-building separation distance)
= 15 cm (All land use categories)
Qsoil
(Volumetric flow rate of soil vapor
into the building)
= 0.81 cm3/s (residential)
= 2.10 cm3/s (nonresidential)
Acrack
(Total area of cracks below grade)
= 196 cm2 (residential)
= 383 cm2 (nonresidential)
exp(p)
(The base of the natural logarithm
raised to power p)
= ep
The effective diffusion coefficient calculation for the vadose zone (
eff
v
D
) is written as:
2
33
.
3
w
w
2
33
.
3
a
a
eff
v
n
TAF
'
H
D
n
D
D
where,
eff
v
D
(Effective diffusion coefficient through
vadose zone)
= chemical-specific, cm2/s
Da
(Diffusivity in air)
= chemical-specific, cm2/s
a
(Soil air-filled porosity)
= 0.13 cm3/cm3
n
(Total soil porosity)
= 0.43 cm3/cm3
Dw
(Diffusivity in water)
= chemical-specific, cm2/s
H’
(Dimensionless Henry’s law constant,
where H’ = HLC x 41)
= chemical-specific, unitless
HLC
(Henry’s law constant
= chemical-specific,
(atm-m3/mol)
w
(Soil water-filled porosity)
= 0.3 cm3/cm3
(4) Facility-specific measurements of the following parameters may be substituted
individually for the generic assumptions and still allow the facility to satisfy the categorical
criteria in section 20120a(1)(a) to (e) of the act:
(a) Dry soil bulk density.
(b) Fraction of organic carbon in soil.
(c) Soil vapor permeability.
(d) Temperature adjustment factor for Henry’s law constant.
Facility-specific measurements shall be based on representative characterization.
Documentation of all facility specific values shall be provided in the response activity plan
or no further action report.
(5) The department may approve methods to demonstrate compliance with criteria for this
exposure pathway if those methods are more representative of in-situ conditions at the
facility. Methods acceptable to the department may include, but are not limited to,
evaluation of representative soil gas concentrations.