R 299.2911 Initial treatment facility and collection system classification.
Cite as Mich. Admin. Code R 299.2911
Rule 11. (1) Except as provided for in subrules (3), (4), and (5) of this rule, treatment
facilities shall be classified by the department into 4 classes, designated as class A, B, C, or
D, with class A being the highest. Collection systems shall be classified by the department
into 4 classes, designated as class C1, C2, C3, or C4, with class C1 being the highest. The
classifications must be based on population served, the type of treatment facility or collection
system, the character and volume of wastes to be treated, and the use and nature of the waters
of the state receiving the effluent thereof. Treatment facilities and collection systems
classified according to the population criteria in subrules (2) and (6) of this rule may be
placed in a higher classification by the department, by reason of the incorporation in the
treatment facility or collection system of special features of design, by characteristics more
difficult to operate than usual, by reasons of a particularly difficult type of sewage, by reason
of particular stream conditions or combinations thereof.
(2) One of the following minimum classifications must be assigned to each treatment
facility that serves the public:
(a) Class A, treatment facilities serving or designed to serve a population of 50,000 or more
persons.
(b) Class B, treatment facilities serving or designed to serve a population of 10,000 or more,
but less than 50,000, persons.
(c) Class C, treatment facilities serving or designed to serve a population of 2,000 or more,
but less than 10,000, persons.
(d) Class D, treatment facilities serving or designed to serve a population of less than 2,000
persons.
(3) Treatment facilities utilizing the waste stabilization lagoon process shall be classified
by the department into 1 of the 2 following classes, designated as class L2 and L1:
(a) Class L2, treatment facilities utilizing the waste stabilization lagoon process that include
special mechanical devices such as aerators, chemical precipitation, disinfection, or other
factors. Class L2 must be considered a higher classification than class L1.
(b) Class L1, treatment facilities utilizing the waste stabilization lagoon process that do not
include special mechanical devices such as aerators, chemical precipitation, disinfection, or
other factors.
(4) Treatment facilities that require minimal operation and control, and serve a population
of less than 1,000 persons may be classified by the department as a special classification,
designated as class SC. These treatment facilities include, but are not limited to, septic tank
and tile field systems, and recirculating sand filters.
(5) Class RTB, treatment facilities that retain and treat discharge from approved facilities
serving a combined sewer system in accordance with its discharge permit.
(6) Collection systems that convey wastewater to a treatment facility, with all flow
transported through a combination of gravity sewers, gravity sewers and pump stations with
force mains, or low-pressure collection systems, must be classified by the department into 1
of the 4 following classes, designated as class C1, C2, C3, or C4, with class C1 being the
highest:
(a) Class C1, collection systems serving or designed to serve a population of 50,000 or
more persons.
(b) Class C2, collection systems serving or designed to serve a population of 10,000 or
more, but less than 50,000, persons.
(c) Class C3, collection systems serving or designed to serve a population of 2,000 or more,
but less than 10,000, persons.
(d) Class C4, collection systems serving or designed to serve a population of 150 or more,
but less than 2,000 persons unless otherwise required by the department.