R 325.10103
R 325.10103 Definitions; C.
Cite as Mich. Admin. Code R 325.10103
Rule 103. As used in these rules:
(a) "C" in "CT calculation" means the residual disinfectant concentration measured in
milligrams per liter in a representative sample of water.
(b) "Cartridge filters" means pressure-driven separation devices that remove particulate
matter larger than 1 micrometer using an engineered porous filtration media. They are
typically constructed as rigid or semi-rigid, self-supporting filter elements housed in
pressure vessels in which flow is from the outside of the cartridge to the inside.
(c) "Casing" means a durable pipe that is placed in a well to prevent the soil from caving
in and to seal off surface drainage or undesirable water, gases, contaminants, or other fluids
and prevent them from entering the well and the aquifer supplying the well.
(d) "Casing vent" means an outlet at the upper terminal of a well casing which provides
atmospheric pressure in the well and which allows the escape of gases when present.
(e) "Certificate" means a document that is issued by the department to a person who
meets the qualification requirements for operating a waterworks system or a portion of the
waterworks system.
(f) "Certified operator" means an operator who holds a certificate.
(g) "Clean compliance history" means, for the purposes of the total coliform provisions
of R 325.10704a to R 325.10704k, a record of no MCL violations under R 325.10602; no
monitoring violations under R 325.10704 to R 325.10709; and no coliform treatment
technique trigger exceedances or treatment technique violations under R 325.10704a to
R 325.10704k.
(h) "Combined distribution system" means the interconnected distribution system
consisting of the distribution systems of wholesale supplies and of the consecutive supplies
that receive finished water.
(i) "Community supply" or "community water supply" or "community water system"
means a public water supply that provides year-round service to not fewer than 15 living
units or that regularly provides year-round service to not fewer than 25 residents.
(j) "Complete treatment" means a series of processes, including disinfection and
filtration, to treat surface water or ground water under the direct influence of surface water,
or to treat ground water not under the direct influence of surface water that uses
precipitative softening, to produce a finished water meeting state drinking water standards.
(k) "Compliance cycle" means the 9-year calendar year cycle during which public water
supplies are required to monitor. Each compliance cycle consists of three 3-year
compliance periods. The first calendar year cycle begins January 1, 1993, and ends
December 31, 2001; the second begins January 1, 2002, and ends December 31, 2010; the
third begins January 1, 2011, and ends December 31, 2019.
(l) "Compliance period" means a 3-year calendar year period within a compliance cycle.
Each compliance cycle has three 3-year compliance periods. Within the first compliance
cycle, the first compliance period runs from January 1, 1993, to December 31, 1995; the
second from January 1, 1996, to December 31, 1998; the third from January 1, 1999, to
December 31, 2001.
(m) "Comprehensive performance evaluation (CPE)" means a thorough review and
analysis of a treatment plant's performance-based capabilities and associated
administrative, operation, and maintenance practices. It is conducted to identify factors that
may be adversely impacting a plant's capability to achieve compliance and emphasizes
approaches that can be implemented without significant capital improvements. For
purposes of compliance, the comprehensive performance evaluation shall consist of at least
all of the following components:
(i) Assessment of plant performance.
(ii) Evaluation of major unit processes.
(iii) Identification and prioritization of performance limiting factors.
(iv) Assessment of the applicability of comprehensive technical assistance.
(v) Preparation of a CPE report.
(n) "Confluent growth" means a continuous bacterial growth that covers the entire
filtration area of a membrane filter, or portion of a filtration area, in which bacterial
colonies are not discrete.
(o) "Consecutive system" or "consecutive supply" means a public water supply that
receives some or all of its finished water from 1 or more wholesale supplies. Delivery may
be through a direct connection or through the distribution system of 1 or more consecutive
supplies.
(p) "Construction" means the erection, installation, or alteration of a waterworks system,
or any portion of a waterworks system, that affects any of the following:
(i) Flow.
(ii) Capacity.
(iii) System service area.
(iv) Source.
(v) Treatment.
(vi) Reliability.
(q) "Contested cases" means matters that are within the definition of a contested case as
set forth by section 3(3) of 1969 PA 306, MCL 24.203(3), and matters of issue that involve
any of the following which are issued by the director, the department, or the division under
the act and these rules:
(i) Orders.
(ii) Exemptions.
(iii) Variances.
(iv) Stipulations.
(v) Consent agreements.
(vi) Permits.
(vii) Licenses.
(viii) Certificates.
(r) "Contested case hearing" means a hearing that is initiated by the department or a
person under chapters 4, 5, and 6 of 1969 PA 306, MCL 24.271 to 24.306.
(s) "Contaminant" means a physical, chemical, biological, or radiological substance or
matter in water.
(t) "Conventional filtration" means a series of processes, including coagulation,
flocculation, sedimentation, and filtration, resulting in substantial particulate removal.
(u) "Corrosion inhibitor" means a substance that is capable of reducing the corrosivity of
water toward metal plumbing materials, especially lead and copper, by forming a protective
film on the interior surface of those materials.
(v) "Cross connection" means a connection or arrangement of piping or appurtenances
through which a backflow could occur.
(w) "CT calculation" means the product of residual disinfectant concentration (C) in
milligrams per liter determined at or before the first customer and the corresponding
disinfectant contact time (T) in minutes; C*T is calculated at rated capacity. The total CT
shall be the sum of individual CTs of each disinfectant sequence.
(x) "Customer service connection" means the pipe between a water main and customer
site piping or building plumbing system.
(y) "Customer site piping" means an underground piping system owned or controlled by
the customer that conveys water from the customer service connection to building
plumbing systems and other points of use on lands owned or controlled by the customer.
Customer site piping does not include any system that incorporates treatment to protect
public health.