R 325.10308b
R 325.10308b Best available technology.
Cite as Mich. Admin. Code R 325.10308b
Rule 308b. (1) The department identifies the following as the best technology, treatment
technique, or other means generally available for achieving compliance with the MCL:
(a) For organic contaminants in R 325.10604b, R325.10604d, and R 325.10604g the best
available technologies, treatment techniques, or other means available for achieving
compliance with the MCLs are granular activated carbon (GAC), packed tower aeration
(PTA), or oxidation (OX), as listed in table 1 of this rule.
Table 1 Best available technologies for organic contaminants
Contaminant
GAC
PTA
OX
Alachlor
x
Aldicarb
x
Aldicarb sulfone
x
Aldicarb sulfoxide
x
Atrazine
x
Benzene
x
x
Benzo(a)pyrene
x
Carbofuran
x
Carbon tetrachloride
x
x
Chlordane
x
Dalapon
x
2,4 D
x
Di (2 ethylhexyl)adipate
x
x
Di (2 ethylhexyl)phthalate
x
Dibromochloropropane (DBCP)
x
x
o Dichlorobenzene
x
x
para Dichlorobenzene
x
x
1,2 Dichloroethane
x
x
1,1 Dichloroethylene
x
x
cis 1,2 Dichloroethylene
x
x
trans 1,2 Dichloroethylene
x
x
Dichloromethane
x
1,2 Dichloropropane
x
x
Dinoseb
x
Contaminant
GAC
PTA
OX
Diquat
x
Endothall
x
Endrin
x
Ethylbenzene
x
x
Ethylene Dibromide (EDB)
x
x
Glyphosate
x
Heptachlor
x
Heptachlor epoxide
x
Hexachlorobenzene
x
Hexachlorocyclopentadiene
x
x
Hexafluoropropylene oxide dimer acid (HFPO-
DA)
x1
Lindane
x
Methoxychlor
x
Monochlorobenzene
x
x
Oxamyl (Vydate)
x
Pentachlorophenol
x
Perfluorobutanesulfonic acid (PFBS)
x1
Perfluorohexanesulfonic acid (PFHxS)
x1
Perfluorohexanoic acid (PFHxA)
x1
Perfluorononanoic acid (PFNA)
x1
Perfluorooctanesulfonic acid (PFOS)
x1
Perfluorooctanoic acid (PFOA)
x1
Picloram
x
Polychlorinated biphenyls(PCB)
x
Simazine
x
Styrene
x
x
2,3,7,8 TCDD (Dioxin)
x
Tetrachloroethylene
x
x
Toluene
x
x
Toxaphene
x
2,4,5 TP (Silvex)
x
1,2,4 Trichlorobenzene
x
x
1,1,1 Trichloroethane
x
x
1,1,2 Trichloroethane
x
x
Trichloroethylene
x
x
Vinyl chloride
x
Xylene
x
x
1Best available technology is GAC or an equally efficient technology.
(b) For inorganic contaminants in R 325.10604c, the best available technologies,
treatment techniques, or other means available for achieving compliance with the MCLs
are listed in table 2 of this rule. The affordable technology, treatment technique, or other
means available to supplies serving 10,000 or fewer people for achieving compliance with
the maximum contaminant level for arsenic are listed in table 3 of this rule.
Table 2 Best available technologies for inorganic contaminants
Chemical name
Best available technologies
Antimony
2,7
Arsenic4
1,2, 5,6,7,9,115
Asbestos
2,3,8
Barium
5,6,7,9
Beryllium
1,2,5,6,7
Cadmium
2,5,6,7
Chromium
2,5,62,7
Cyanide
5,7,10
Mercury
21,4,61,7 1
Nickel
5,6,7
Nitrate
5,7,9
Nitrite
5,7
Selenium
1,23,6,7,9
Thallium
1,5
1Best available technology only if influent Hg concentrations are 10 µg/l or less.
2Best available technology for chromium III only.
3Best available technology for selenium IV only.
4BATs for Arsenic V. Pre-oxidation may be required to convert Arsenic III to Arsenic
V.
5To obtain high removals, iron to arsenic ratio must be at least 20:1.
Key to best available technologies in table:
1 = activated alumina
2 = coagulation/filtration (not BAT for supplies with fewer than 500 service
connections)
3 = direct and diatomite filtration
4 = granular activated carbon
5 = ion exchange
6 = lime softening (not BAT for supplies than 500 service connections)
7 = reverse osmosis
8 = corrosion control
9 = electrodialysis
10 = alkaline chlorination (pH greater than or equal to 8.5)
11 = oxidation/filtration
Table 3 Small supplies compliance technologies (SSCTs) for arsenic1
Small supply compliance technology
Affordable for listed small supply
categories.2
Activated alumina (centralized)
All size categories.
Small supply compliance technology
Affordable for listed small supply
categories.2
Activated alumina (point-of-use)3
All size categories.
Coagulation/filtration
501-3,300, 3,301-10,000.
Coagulation-assisted microfiltration
501-3,300, 3,301-10,000.
Electrodialysis reversal
501-3,300, 3,301-10,000.
Enhanced coagulation/filtration
All size categories.
Enhanced lime softening (pH more
than 10.5)
All size categories.
Ion exchange
All size categories.
Lime softening
501-3,300, 3,301-10,000.
Oxidation/filtration4
All size categories.
Reverse osmosis (centralized)
501-3,300, 3,301-10,000.
Reverse osmosis (point-of-use)3
All size categories.
1 SSCTs for Arsenic V. Pre-oxidation may be required to convert Arsenic III to
Arsenic V.
2Three categories of small supplies are: (i) those serving 25 or more, but fewer than
501, (ii) those serving more than 500, but fewer than 3,301, and (iii) those serving
more than 3,300, but fewer than 10,001.
3POU must not be used to obtain a variance.
4To obtain high removals, iron to arsenic ratio must be at least 20:1.
(c) For radionuclide contaminants in R 325.10603, the best available technologies,
treatment techniques, or other means available for achieving compliance with the MCLs
are listed in table 4 for all size supplies. The affordable technology, treatment technique,
or other means available for achieving compliance with the maximum contaminant level
are listed in table 5 for supplies serving 10,000 or fewer people as categorized in table 6.
Table 4 Best available technologies for radionuclide contaminants
Contaminant
Best available technologies.
Combined radium 226 and radium
228
Ion exchange, reverse osmosis, lime
softening.
Uranium
Ion exchange, reverse osmosis, lime
softening, coagulation/filtration.
Gross alpha particle activity
(excluding radon and uranium)
Reverse osmosis.
Beta particle and proton radioactivity
Ion exchange, reverse osmosis.
Table 5 List of small supplies compliance technologies for radionuclides and limitations
to use
Unit Technologies
Limitations (see
footnotes)
Operator skill level
required *
Raw water quality
range and
considerations.
1. Ion exchange
(a)
Intermediate
All ground waters.
2. Reverse osmosis
(RO)
(b)
Advanced
Surface waters
usually require pre-
filtration.
3. Lime softening
(c)
Advanced
All waters.
4. Green sand
filtration
(d)
Basic
5. Co-precipitation
and Barium sulfate
(e)
Intermediate to
Advanced
Ground waters with
suitable water
quality.
6. Electrodialysis/
electrodialysis
reversal
Not applicable
Basic to
intermediate
All ground waters.
7. Pre-formed
hydrous Manganese
oxide filtration.
(f)
Intermediate
All ground waters.
8. Activated
alumina
(a), (g)
Advanced
All ground waters;
competing anion
concentrations may
affect regeneration
frequency.
9. Enhanced
coagulation/
filtration
(h)
Advanced
Can treat a wide
range of water
qualities.
* An operator with a basic skill level has minimal experience in the water treatment
field and can perform the necessary system operation and monitoring if provided with
proper instruction. The operator is capable of reading and following explicit directions.
An operator with an intermediate skill level understands the principles of water treatment
and has a knowledge of the regulatory framework. The operator is capable of making
system changes in response to source water fluctuations. An operator with an advanced
skill level possesses a thorough understanding of the principles of system operation. The
operator is knowledgeable in water treatment and regulatory requirements. The operator
may, however, have advanced knowledge of only the particular treatment technology.
The operator seeks information, remains informed, and reliably interprets and responds to
water fluctuations and system intricacies.
Limitations Footnotes: Technologies for Radionuclides:
a. The regeneration solution contains high concentrations of the contaminant ions.
Disposal options must be carefully considered before choosing this technology.
b. Reject water disposal options must be carefully considered before choosing this
technology.
c. The combination of variable source water quality and the complexity of the water
chemistry involved may make this technology too complex for small surface water
systems.
d. Removal efficiencies may vary depending on water quality.
e. This technology may be very limited in application to small systems. Since the
process requires static mixing, detention basins, and filtration, it is most applicable
to systems with sufficiently high sulfate levels that already have a suitable
filtration treatment train in place.
f. This technology is most applicable to small systems that already have filtration in
place.
g. Handling of chemicals required during regeneration and pH adjustment may be too
difficult for small systems without an adequately trained operator.
h. Assumes modification to a coagulation/filtration process already in place.
Table 6 Compliance technologies by supply size category for radionuclide
Requirements
Contaminant
Compliance technologies* for supply size categories
(population served)
25-500
501-3,300
3,301 – 10,000
1. Combined radium
226 and radium 228
1, 2, 3, 4, 5, 6, 7
1, 2, 3, 4, 5, 6, 7
1, 2, 3, 4, 5, 6, 7
2. Gross alpha
particle activity
2
2
2
3. Beta particle
activity and photon
activity
1, 2
1, 2
1, 2
4. Uranium
1, 8, 9
1, 2, 3, 8, 9
1, 2, 3, 8, 9
* Numbers correspond to those technologies listed in Table 5 of this rule.
(2) The department shall require community water supplies and nontransient,
noncommunity water supplies to employ a treatment method identified in subrule (1) of
this rule as a condition for granting a variance, except as provided in subrule (3) of this
rule. If, after the treatment method is installed in the system, the supply cannot meet the
MCL, then the supply is eligible for a variance under this part and section 20 of the act,
MCL 325.1020.
(3) If a supply demonstrates through comprehensive engineering assessments, which may
include pilot plant studies, that the treatment methods identified in subrule (1) of this rule
may only achieve a de minimis reduction in contaminants, then the department may issue
a schedule of compliance that requires the supply being granted the variance to examine
other treatment methods as a condition of obtaining the variance.
(4) If the department determines that a treatment method identified in subrule (3) of this
rule is technically feasible, then the department may require the supply to use that treatment
method in connection with a compliance schedule issued under section 20 of the act, MCL
325.1020. The department's determination must be based on studies by the supply and other
relevant information.
(5) The department may require a community or noncommunity supply to use point-of-
use devices, point-of-entry devices, or other means as a condition of granting a variance or
an exemption from the requirements of R 325.10603, R 325.10604b, R 325.10604c,
R 325.10604d, or R325.10604g to avoid an unreasonable risk to health. The department
may require a public water supply to use point-of-use devices or other means, but not point-
of-entry devices, as a condition for granting an exemption from corrosion control treatment
requirements for lead and copper in R 325.10604f(2) and (3) to avoid an unreasonable risk
to health. The department may require a public water supply to use point-of-entry devices
as a condition for granting an exemption from the source water and lead service line
replacement requirements for lead and copper under R 325.10604f(4) and (5) to avoid an
unreasonable risk to health, provided the supply demonstrates that the device will not cause
an increased corrosion of lead and copper bearing materials located between the device and
the tap that may increase contaminant levels at the tap.
(6) Community or noncommunity water supplies that use point-of-use or point-of-entry
devices under this rule shall meet the conditions in R 325.10313.