R 325.10604b
R 325.10604b MCLs for volatile organic chemicals other than total trihalomethanes.
Cite as Mich. Admin. Code R 325.10604b
Rule 604b. (1) The maximum contaminant levels and effective dates for volatile organic
chemicals in table 1 of this rule apply to community and nontransient noncommunity water
supplies.
Table 1 MCLs for volatile organic chemicals
Contaminant
Maximum Contaminant
Level in mg/l
Effective Date
Benzene
0.005
January 9, 1989.
Vinyl chloride
0.002
January 9, 1989.
Carbon tetrachloride
0.005
January 9, 1989.
1,2-dichloroethane
0.005
January 9, 1989.
Trichloroethylene
0.005
January 9, 1989.
1,1-dichloroethylene
0.007
January 9, 1989.
1,1,1-trichloroethane
0.20
January 9, 1989.
para-dichlorobenzene
0.075
January 9, 1989.
cis-1,2-dichloroethylene
0.07
July 30, 1992.
1,2-dichloropropane
0.005
July 30, 1992.
Ethylbenzene
0.7
July 30, 1992.
Monochlorobenzene
0.1
July 30, 1992.
0-dichlorobenzene
0.6
July 30, 1992.
Contaminant
Maximum Contaminant
Level in mg/l
Effective Date
Styrene
0.1
July 30, 1992.
Tetrachloroethylene
0.005
July 30, 1992.
Toluene
1
July 30, 1992.
trans-1, 2-dichloroethylene
0.1
July 30, 1992.
Xylenes (total)
10
July 30, 1992.
Dichloromethane
0.005
January 17, 1994.
1,2,4-Trichlorobenzene
0.07
January 17, 1994.
1,1,2-Trichloroethane
0.005
January 17, 1994.
(2) Compliance with the MCLs in table 1 of this rule shall be determined based on the
analytical results obtained at each sampling point. If 1 sampling point is in violation of the
MCL, then the supply is in violation of the MCL. All of the following provisions apply:
(a) For supplies monitoring more than once per year, compliance with the MCL is
determined by a running annual average at each sampling point.
(b) Supplies monitoring annually or less frequently whose sample result exceeds the MCL
shall begin quarterly sampling. Compliance with the MCL shall be based on the running
annual average. For the purpose of calculating the running annual average, the initial
exceedance shall be considered the result for the first quarter. If the department requires a
confirmation sample under R 325.10716(15), then the average of the initial exceedance and
the confirmation sample shall be considered the result for the first quarter. The supply shall
not be considered in violation of the MCL until it has completed 1 year of quarterly
sampling.
(c) If any sample result causes the running annual average to exceed the MCL at any
sampling point, then the supply is out of compliance with the MCL immediately.
(d) If a supply fails to collect the required number of samples, then compliance shall be
based on the total number of samples collected.
(e) If a sample result is less than the detection limit, then zero shall be used to calculate
the annual average.