R 325.10717d Collection and analysis of samples for per- and polyfluoroalkyl substances.
Cite as Mich. Admin. Code R 325.10717d
Rule 717d. (1) Suppliers of community and nontransient noncommunity water supplies
shall collect samples and cause analyses to be made under this rule for per- and
polyfluoroalkyl substances to determine compliance with the state drinking water standards
in R 325.10604g. Each supplier shall monitor at the time designated by the department.
(2) For transient noncommunity and type III public water supplies, the department may
require samples to be collected and analyzed at prescribed frequencies for per- and
polyfluoroalkyl substances.
(3) A groundwater supplier shall take at least 1 sample at every entry point to the
distribution system that is representative of each well after treatment, also known as
sampling point. Each sample must be taken at the same sampling point unless conditions
make another sampling point more representative of each source or treatment plant.
(4) A surface water supplier, or combined surface water and ground water, shall take at
least 1 sample at points in the distribution system that are representative of each source or
at each entry point to the distribution system after treatment, also known as sampling point.
Each sample must be taken at the same sampling point unless conditions make another
sampling point more representative of each source or treatment plant.
(5) If a system draws water from more than 1 source and the sources are combined before
distribution, then the supplier shall sample at an entry point to the distribution system
during periods of normal operating conditions when water that is representative of all
sources is being used.
(6) An existing supplier with one or more samples taken at each sampling point described
in subrules (3), (4), or (5) of this rule as part of the State of Michigan’s 2018/2019
Statewide PFAS Survey shall conduct initial sampling as follows:
(a) A supplier with one or more sample results greater than 50% of the MCL for a
contaminant listed in rule 10604g shall collect samples from each sampling point beginning
the first full quarter following the effective date of this rule.
(b) A supplier with no detection or a detection less than or equal to 50% of the MCL for
a contaminant listed in rule 10604g shall collect at least 1 sample from each sampling point
within 6 months of the effective date of this rule.
(7) An existing supplier without sampling conducted under subrule (6) of this rule, shall
collect samples beginning the first full quarter following the effective date of this rule.
(8) A new community or nontransient noncommunity water supply shall collect samples
beginning the first full quarter following the initiation of operations.
(9) If the results of samples collected under subrules (6), (7), or (8) of this rule are below
the reporting limits specified in R 325.12708, the department may allow the water supply
to monitor annually.
(10) If a contaminant in R 325.10604g is detected above the reporting limit in any sample,
then all of the following provisions apply:
(a) Each supply shall monitor quarterly at each sampling point that resulted in a
detection. The department may decrease the quarterly monitoring requirement specified in
this subrule if it has determined that the supply is reliably and consistently below the MCL.
A groundwater supplier shall take not fewer than 2 quarterly samples and a surface water
supplier shall take not fewer than 4 quarterly samples before this determination.
(b) After the department determines that the supply is reliably and consistently below
the MCL, the department may allow the supply to monitor annually.
(11) A supplier that violates R 325.10604g shall monitor quarterly. If not fewer than 4
quarterly samples show that the supply is in compliance and the department determines the
supply is reliably and consistently below the MCL, then the department may allow the
supply to monitor annually.
(12) The department may require confirmation sampling for positive or negative results.
If confirmation sampling is required, then the results must be averaged with the first
sampling result and the average must be used for the compliance determination. The
department may exclude results of obvious sampling errors from this calculation.
(13) The department may increase the required monitoring to detect variations within the
system.
(14) All new supplies or supplies that use a new source of water shall demonstrate
compliance with the MCLs before serving water to the public. The supply shall also comply
with the initial sampling frequencies specified by the department.