R 325.1571
R 325.1571 Service buildings; required facilities.
Cite as Mich. Admin. Code R 325.1571
Rule 21. (1) If a service building is proposed for a campground, then the campground
owner shall ensure that the building is constructed in accordance with the applicable state
or local building code and shall include the building details and specifications on the plan
required by R 325.1553. In addition, the campground owner shall ensure that all of the
following requirements are complied with:
(a) A window that opens is screened. An exterior door has a self-closing device.
(b) An adequate amount of light for cleaning and safety purposes is provided in the
service building.
(c) Coved floor and wall joints are provided.
(d) The location of all toilets, lavatories, showers, urinals, enclosures, and floor drains is
specified on theplans.
(2) The campground owner shall ensure that a service building at a modern campground
is provided with toilet, urinal, and lavatory facilities in accordance with the following
schedule:
Campground Minimum Number of Fixtures
Sites
Toilets
M F
Urinals
M
Lavatories
M F
1-15
1
1
1
1
1
16-30
1
2
1
2
2
31-45
2
2
1
3
3
46-60
2
3
2
3
3
61-100
3
4
2
4
4
101-130
4
5
3
5
5
131-160
5
6
3
6
6
161-190
6
7
3
7
7
191-220
7
8
4
8
8
221-250
8
9
4
9
9
251-280
9
10
4
10 10
281-310
10 11
5
11 11
311-340
11 12
5
12 12
341-370
12 13
5
13 13
371-400
13 14
5
14 14
401-430
14 15
6
15 15
431-460
15 16
6
16 16
461-490
16 17
6
17 17
491-520*
17 18
7
18 18
*A campground that has more than 520 sites shall provide 1 additional toilet and lavatory
for each sex for each additional 30 sites or part of 30 sites and 1 additional men's urinal for
each additional 100 sites.
(3) In a modern campground, if all the sites are provided with water and sewer services
and if occupancy is limited to recreational units connected to the water and sewer systems,
then a campground owner shall ensure that, at a minimum, 1 water flush toilet and 1
lavatory are provided.
(4) In a campground where only a portion of the sites are provided with water and sewer
services, a campground owner shall ensure that the fixture schedule specified in subrule
(2) of this rule is complied with for sites that do not have water and sewer services. The
portion of a campground that is restricted to single sectional mobile homes that have sewer
and water connections is exempt from the fixture schedule specified in subrule (2) of this
rule.
(5) A campground owner has the option of providing showers. A campground that
constructs a service building that has showers shall comply with the following schedule:
Shower Schedule
*Sites
1-45
46-80
81-100
101-150
151-200
201-250
Male
1
2
3
4
5
6
Female
1
2
3
4
5
6
**Sites
1-15 16-45 46-
60
61-80 81-
100
101-
130
131-
160
161-
190
191-
220
221-
250
Unisex
1
2
3
4
5
6
7
8
9
10
*A campground that has more than 250 sites shall provide 1 shower for each sex for every
50 sites or part of 50 sites.
**A campground that has more than 250 sites shall provide 1 shower for every 30 sites or
part of 30 sites.
(6) A campground owner shall provide an effective method, such as curbing or recessed
floors, and shower curtains or partitions to keep shower water from dressing rooms and
other areas in the service building. A campground owner shall provide a means of
regulating the temperature of hot water so that the water temperature will not be more than