R 325.2175
R 325.2175 Bathhouse plumbing fixtures.
Cite as Mich. Admin. Code R 325.2175
Rule 75. (1) A swimming pool owner shall ensure that a bathhouse has showers and toilet
facilities that are in compliance with the specifications of table 2 of this rule.
(2) Table 2 reads as follows:
Table 2
Minimum Bathhouse Fixtures
Maximum
Bather
Capacity* per
R 325.2193
Number of fixtures
for each sex
Number of toilet
fixtures toilet
fixtures
For
males
For
females
Showers**
Lavatories
Water
closets
Urinals
***
Water
closets
1-50
51-100
101-200
201-300
301-500
501-700
701-1,000
1
2
3
4
5
6
7
1
2
2
3
3
4
4
2
2
3
4
5
6
7
0
1
1
1
1
1
1
2
3
4
5
6
7
8
* In addition, a swimming pool owner shall provide 1 shower, 1 water closet, and 1
lavatory for each sex for each additional 300 persons, or fraction of 300 persons, starting
at 1,001.
**At a swimming pool used by school classes, a swimming pool owner shall provide 1
shower for every 3 people in the largest class for each sex. A owner may substitute
nonenclosed poolside showers for showers in accordance with R 325.2174.
***An owner may substitute urinals for not more than ½ of the required number of water
closets.