R 325.52011
R 325.52011 Recirculation of air from exhaust systems.
Cite as Mich. Admin. Code R 325.52011
Rule 11.(1) The recirculation of air containing a contaminant whose permissible
exposure limit is equal to or exceeds 1000 ppm, 15 mg/m3, or 50 mppcf, shall be
permitted if the exhaust ventilation system is equipped with an air-cleaning device
capable of reducing the contaminant concentrations to 10% or less of their permissible
exposure limits in the returned air.
(2) The director may allow the recirculation of air containing a contaminant whose
permissible exposure limit is less than 1000 ppm, 15 mg/m3, or 50 mppcf, if the toxicity
of the contaminant and the degree of air cleaning to be achieved create an environment
that will not impair the health of the workers, and if the contaminant concentrations in the
return air does not exceed 10% of its permissible exposure limits.
(3) A recirculation system shall include an alternate air duct connection to discharge
the return air outside of the building if necessary to protect the workers' health.
(4) Spray-finishing operations using flammable and combustible materials shall be
as prescribed in General Industry Safety Standard Part 76 “Spray Finishing Using
Flammable and Combustible Materials,” as referenced in R 325.52002.