R 325.5222
R 325.5222 Personnel monitoring.
Cite as Mich. Admin. Code R 325.5222
Rule 222. (1) Each licensee or registrant shall supply appropriate personnel monitoring
equipment to, shall require the use of such equipment by, and shall demonstrate compliance
pursuant to this rule for the following:
(a) Each individual under such circumstances that he or she receives, or is likely to receive, a
dose in any calendar quarter in excess of 25% of the quarterly occupational limit specified in Rule
205, (e.g. 300 mrems whole body).
(b) Each individual under 18 years of age under such circumstances that he or she receives, or is
likely to receive, a dose in any calendar quarter in excess of 5% of the quarterly occupational limit
specified in Rule 205, (e.g. 60 mrems whole body).
(c) Each individual, except a patient being intentionally irradiated, who enters a high radiation
area.
(d) Each individual who is likely to receive a dose in excess of 100 millirems in any 5 consecutive
days while in a room or area occupied by a patient while the patient is receiving therapy from any
gamma-emitting radioactive material.
(e) Each individual for whom personnel monitoring is specifically required under other parts of
these rules pertaining to specific uses of sources of radiation.
(2) Monitoring devices used to estimate whole body exposure shall normally be worn on the chest
or abdomen. The dosimeter assigned for monitoring the trunk of the body shall not be used for any
other purposes. If monitoring of other areas of the body (e.g. lens of the eye, extremity) is required
by these rules or requested by the radiation worker because of the nature of exposure, a separate
dosimeter shall be assigned for this purpose. The separate dosimeter shall be designated as an
auxiliary dosimeter and the radiation record shall specify the specific area monitored.
(3) If auxiliary dosimeters are assigned in accordance with subrule (2) of this rule, the specific
body area shall be monitored for a minimum 13 consecutive weeks. If this monitoring results in
recorded exposures in excess of 25% of the applicable specified quarterly limit in Rule 205 (e.g.
300 mrems lens of the eye, 6.25 rems hands), the auxiliary dosimeter shall be permanently assigned
to monitor that area.