R 325.5272
R 325.5272 Appendix C. Radioactive surface contamination guides.
Cite as Mich. Admin. Code R 325.5272
Rule 272.
Application
Alpha(dpm/100 cm2)
Beta/Gamma*
Total (mR/hr)
Removable (dpm/100 cm2)
Total
Removable
Restricted Area
Basic Guide
25,000 (max)
500
1.0
5,000
5,000 (avg)
Clean Area
1,000
100
0.5
1,000
Non-Restricted Area
Skin, Personal Clothing
500
N.D.**
0.1
N.D.**
Release of Material or
Facilities
2,500 (max)
100
0.2
1,000
500 (avg)
*Measured at 1 cm from the surface
**N.D. - non-detectable
NOTES TO APPENDIX C
It should be emphasized that because of the wide range of physical factors, no one value (of the
few which can be incorporated in a standard) can relate health effects to contamination levels in
all the diverse situations in which contamination is measured. Accordingly, standards for
contamination levels must be used as guides (or decision levels). The above levels shall therefore
be applied with the following guidance:
1. The levels are to be used as guides, and in practice professional judgment should be used by
the health physicist to determine the acceptability of the actual contamination.
2. Although it is felt that the recommended values should not result in a health hazard, good
radiation protection practice dictates that a reasonable effort be made to keep actual contamination
levels below these values.
3. Compliance with contamination guides shall not be used as evidence that exposing persons to
internal or external sources of radiation is within the prescribed standards. Biological sampling or
whole body counting should be used to ascertain internal doses.
4. For release of material to the general public:
a. A reasonable effort shall be made to minimize the contamination (i.e. the application of
additional decontamination procedures have little effect on the contamination levels).
b. Surfaces of premises or equipment likely to be contaminated that are inaccessible for
measurement shall be presumed to be contaminated in excess of the above limits and not
released.
5. The levels adopted are for generally used isotopes of high toxicity, therefore lower levels may
be appropriate for extremely toxic radionuclides and relaxations allowed for less toxic
radionuclides.