R 333.5448
R 333.5448 Accelerator controls and interlock systems.
Cite as Mich. Admin. Code R 333.5448
Rule 448. (1) Instrumentation, readouts, and controls on the accelerator control
console shall be clearly identified and easily discernible.
(2) All entrances or openings into a target room or other high radiation area shall be
provided with interlocks.
(3) When an interlock system has been tripped, operation of the accelerator shall only
be resumed by first manually resetting controls at the position where the interlock has
been tripped, and lastly at the main control console.
(4) A safety interlock shall be on a circuit which will allow it to operate
independently of all other safety interlocks.
(5) A safety interlock shall be fail safe. A defect or component failure in the interlock
system shall prevent operation of the accelerator.
(6) A scram button or other emergency power cutoff switch shall be located and
easily identifiable in all high radiation areas. This cutoff switch shall include a manual
reset so that the accelerator cannot be restarted from the accelerator control console
without resetting the cutoff switch.