R 336.1107
R 336.1107 Definitions; G.
Cite as Mich. Admin. Code R 336.1107
Rule 107. As used in these rules:
(a) "Gasoline" means any petroleum distillate which has a Reid vapor pressure equal to
or greater than 4.0 psia and which is used for automotive fuel.
(b) "Geographical site" means contiguous land ownership by 1 landowner. A public right
of way, such as a road, railroad, and watercourse, through part of the site, is not considered
to break the continuity. Where transmission and fuel delivery rights-of-way or a strip of
land that serves no other purpose than as a transportation or materials handling link
connects 2 or more otherwise separate geographical sites, the connected sites shall be
considered separate geographical sites.
(c) "Good engineering practice design" means, with respect to stack heights, the height
necessary to ensure that emissions from the stack result in acceptable concentrations of air
contaminants in the immediate vicinity of the stationary source as a result of atmospheric
downwash, eddies, and wakes which may be created by the stationary source itself, nearby
structures, or nearby terrain obstacles and will not exceed the greatest of the following
limits:
(i) Two hundred and thirteen feet (65 meters).
(ii) Two and one-half times the height of the structure or nearby structure for those stacks
for which construction or modification commenced on or before January 12, 1979, if the
owner or operator produces evidence that this relationship was actually relied upon in
designing the stack to ensure protection against downwash.
(iii) The sum of the height of the structure or nearby structure plus 1.5 times the lesser of
the height or width of the structure or nearby structure for those stacks for which
construction or modification commenced after January 12, 1979.
(iv) Such height as an owner or operator of a stationary source demonstrates, to the
satisfaction of the department, is necessary through the use of field studies or fluid models
after notice and opportunity for public hearing.
(d) "Gloss reducer" means a coating that is applied to a plastic part solely to reduce the
shine of the part. A gloss reducer shall not be applied at a thickness of more than 0.5 mils
of coating solids.
(e) "Graphic arts line" means an operation or series of operations in which printing (the
formation of words), designs, or pictures on a substrate by means of partial coverage of the
substrate are employed. A graphic arts line may also employ 1 or more coating operations
in which a uniform layer of coating is applied either across the entire width of the substrate
or across only certain portions of the substrate.