R 336.1284
R 336.1284 Permit to install exemptions; containers.
Cite as Mich. Admin. Code R 336.1284
Rule 284. (1) This rule does not apply if prohibited by R 336.1278 and unless the
requirements of R 336.1278a have been met.
(2) The requirement of R 336.1201(1) to obtain a permit to install does not apply to
containers, reservoirs, or tanks used exclusively for any of the following:
(a) Dipping or storage operations for coating objects with oils, waxes, greases, or natural
or synthetic resins containing no organic solvents.
(b) Storage of butane, propane, or liquefied petroleum gas in a vessel that has a capacity
of less than 40,000 gallons.
(c) Storage and surge capacity of lubricating, hydraulic, and thermal oils and indirect heat
transfer fluids.
(d) Storage of no. 1 to no. 6 fuel oils as specified in ASTM D396, gas turbine fuel oils
No. 2-GT to 4-GT as specified in ASTM D2880, aviation gas as specified in ASTM D910,
jet fuels as specified in ASTM D1655, diesel fuel oils no. 2-D and 4-D as specified in
ASTM D975, or biodiesel fuel oil and blends as specified in ASTM D6751 and ASTM
D7467. The ASTM methods are adopted by reference in R 336.1902.
(e) Storage of sweet crude or sweet condensate in a vessel that has a capacity of less than
40,000 gallons.
(f) Storage of sour crude or sour condensate in a vessel that has a capacity of less than
40,000 gallons if vapor recovery or its equivalent is used to prevent the emission of vapors
to the atmosphere.
(g) Storage and handling equipment for gasoline, gasoline blends including ethanol, diesel
fuel, or natural gas as follows:
(i) Loading facilities handling less than 20,000 gallons per day for storage, mixing,
blending, and handling of gasoline, and/or gasoline/ethanol blends, or for diesel fuel
storage and handling.
(ii) Dispensing facilities for storage, mixing, blending and handling of gasoline and/or
gasoline/ethanol blends, for natural gas storage and handling, or for diesel fuel storage and
handling.
(iii) Equipment exclusively serving dynamometer facilities for gasoline and/or
gasoline/ethanol blends storage and handling, for natural gas storage and handling, or for
diesel fuel storage and handling.
(h) Storage and water dilution of aqueous solutions of inorganic salts, bases, and the
following acids:
(i) Sulfuric acid that is not more than 99% by weight.
(ii) Phosphoric acid that is not more than 99% by weight.
(iii) Nitric acid that is not more than 20% by weight.
(iv) Hydrochloric acid that is not more than 11% by weight.
(i) Storage, mixing, blending, or transfer operations of volatile organic compounds or
noncarcinogenic liquids in a vessel that has a capacity of not more than 40,000 gallons
where the contents have a true vapor pressure of not more than 1.5 psia at the actual storage
conditions.
(j) Pressurized storage of acetylene, hydrogen, oxygen, nitrogen, helium, and other
substances, excluding chlorine and anhydrous ammonia in a quantity of more than 500
gallons, that have a boiling point of 0 degrees Celsius or lower.
(k) Storage containers and transfer operations of noncarcinogenic solid material,
including silos, that only emit particulate matter and that are controlled with an
appropriately designed and operated fabric filter collector system or an equivalent control
system.
(l) Filling of noncarcinogenic liquids in shipping or storage containers that have emissions
that are released only into the general in-plant environment.
(m) Storage of wood and wood residues.
(n) Storage of methanol in a vessel that has a capacity of not more than 30,000 gallons.