R 336.1930
R 336.1930 Emission of carbon monoxide from ferrous cupola operations.
Cite as Mich. Admin. Code R 336.1930
Rule 930. (1) It is unlawful for a person to operate a ferrous cupola that has a melting
capacity of 20 or more tons per hour located within any area listed in Table 91, unless the
ferrous cupola is equipped with an afterburner control system, or equivalent, which reduces
the carbon monoxide emissions from the ferrous cupola by 90%.
(2) The emission rate of carbon monoxide from a ferrous cupola shall be determined by
using 40 C.F.R. Part 60, Appendix A, reference test method 10, adopted by reference in
R 336.1902, unless otherwise specified by the department.
TABLE 91
Areas Subject to R 336.1930
County
Area
Wayne
T01S, R09E to R12E
T02S, R09E to R11E
T03S, R09E to R10E