R 336.2003
R 336.2003 Performance test criteria.
Cite as Mich. Admin. Code R 336.2003
Rule 1003. (1) Performance tests must be conducted and data reduced according to the
reference test methods listed in R 336.2004, unless the department does any of the
following:
(a) Specifies or approves, in specific cases, the use of a reference test method with minor
changes in procedures or equipment.
(b) Approves the use of an equivalent method.
(c) Specifies or approves the use of an alternative method if an applicable reference test
method does not exist for a specific air contaminant or source of air contaminant.
(2) Unless otherwise approved by the department, a performance test must consist of a
minimum of 3 separate samples of a specific air contaminant conducted within a 36-hour
period that starts once the probe enters the stack. Any data measured within the 36-hour
period must be recorded and provided to the department. Each of the 3 separate samples
must be obtained while the source is operating at a similar production level, as described
under subrule (3) of this rule. For the purpose of determining compliance with an applicable
emission limit, rule, or permit condition, the arithmetic mean of results of the 3 samples
must apply. If a sample is accidentally lost or conditions occur in which 1 of the 3 samples
must be discontinued because of forced shutdown, failure of an irreplaceable portion of the
sampling train, extreme meteorological conditions, or other circumstances beyond the
owner's or operator's control, then compliance may, upon the approval of the department,
be determined using the arithmetic mean of the results of 2 samples.
(3) All performance tests must be conducted while the source of air contaminant is
operating at maximum routine operating conditions, or under other conditions, within the
capacity of the equipment, as may be requested by the department. Other conditions may
include source operating periods of startup, shutdown, or other operations, excluding
malfunction, specific to certain sources. Routine operating conditions must also include
those specified within a permit to install or a permit to operate. The owner or operator shall
make available to the department the records that may be necessary to determine the
conditions of source operation that occurred during the period of time of the performance
test.
(4) For sources that are subject to an emission limitation calculated to 50% excess air, the
multipoint, integrated sampling at every traverse point must be used with method 3, 3A, or
3Bfor gas analysis. For all other sources that require a determination of the molecular
weight of the exhaust, an optional sampling procedure of method 3, 3A, or 3B may be used.
Alternatives or modifications to procedures are subject to the approval of the department.
(5) For reference test method 5B, which is described in R 336.2011, reference test method
5C, which is described in R 336.2012, and reference test method 5E, which is described in
R 336.1014, the minimum volume per sample must be 30 cubic feet of dry gas corrected
to standard conditions, 68 degrees Fahrenheit, 29.92 inches mercury. Minimum sample
time must be 60 minutes, which may be continuous or a combination of shorter sampling
periods for sources that operate in a cyclic manner. Smaller sampling times or sample
volumes, when necessitated by process variables or other factors, may be approved by the
department.