R 336.2006
R 336.2006 Reference test method serving as alternate version of federal reference test method 25 by incorporating Byron analysis.
Cite as Mich. Admin. Code R 336.2006
Rule 1006. When using the alternate version of federal reference test method 25
incorporating the Byron analysis, the procedures in method 25, which are described in R
336.2004, shall be followed, except that all of the following parts in method 25 are
amended to read as follows:
1.2 Principle. An emission sample is withdrawn from a stack at a constant rate through a
stainless steel absorber tube packed with porasil; the gaseous portion of the sample is pulled
past a battery-operated sampling pump into a tedlar bag. After sampling is complete, the
contents of the tedlar bag are analyzed on an automated gas chromatograph (GC), and the
sample in the porasil packed tube is heated to remove all components for analysis on the
GC. The GC separates CO, CO2, and CH4 from the nonmethane organics (NMO), then
converts the NMOs to methane for analysis.
2. Apparatus. The sampling system consists of a nonmethane organic (NMO) absorber
tube, a sampling pump, and a sample bag (figure 25-1). The analytical system has 2 parts
the oven for removing the sample from the absorber tube and an automated gas
chromatograph (GC).
2.1 Sampling. All of the following equipment is required, as shown in figure 25-1:
2.1.1 Heated probe. 6.4-millimeter (mm) (1/4-inch (in.)) outside diameter (o.d.) stainless
steel tubing with a heating system that is capable of maintaining a gas temperature at the
exit end of not less than 129 degrees Centigrade (265 degrees Fahrenheit). The probe shall
be equipped with a thermocouple at the exit end to monitor the gas temperature. The nozzle
is an elbow fitting that is attached to the front end of the probe while the thermocouple is
inserted in the side arm of a tee fitting that is attached to the rear of the probe. The probe
is wrapped with a suitable length of high-temperature heating tape and then covered with
2 layers of glass cloth insulation and 1 layer of aluminum foil.
2.1.2 Heated prefilter-only for stacks with possible particulate matter interference. A
stainless steel filter holder with a 47-mm type A/E fiberglass filter without organic binder.
The entire prefilter shall be maintained at 110 degrees Celsius. Note - if it is not possible
to use a heating system for safety reasons, an unheated system with an instack filter is a
suitable alternative.
2.1.3 NMO absorber tube. 1/2-inch inside diameter (i.d.) stainless steel tube packed with
porasil (thermally stable silica gel).
2.1.4 1/4-inch o.d. teflon line that is 2 to 4 feet long.
2.1.5 Battery-operated diaphragm sampling pump with kurz digital mass flow meter.
Total flow is integrated electronically to measure flow with an accuracy of 1% at any flow
rate. (Byron instruments model 90).
2.1.6 Sample bag. 0.3-mil tedlar, 1/2-cubic foot capacity. The sample bag undergoes
nitrogen purge cycle until analysis exhibits zero carbon content in the sample bag.
2.2 Analysis. The following equipment is required:
2.2.1 Sample recovery on the adsorber tube is done in a Byron model 75 oven in 2 stages,
each stage requiring a 0.3-mil tedlar bag that has a 1/2-cubic foot capacity.
2.2.2 Analysis is done on a Byron model 401 gas chromatograph (GC) that meets all
criteria specified in method 25, section 2.2.2.
2.3 NMO analyzer. The NMO analyzer is a Byron model 401 gas chromatograph (GC).
(Remainder of 2.3 as stated in method 25)
2.3.5.2 Range. A full scale range of 1 to 10,000 parts per million (ppm) CH4. Signal
attenuators shall be available to produce a minimum signal response of 10% of full scale.
3.1.1 Delete (dry ice is not required).
4.1.1 Model 90 and model 75 flow meter calibration. The model 90 sample pump inlet is
attached to the outlet of the model 75 oven. Air is passed through the system at the rate that
will be used in sampling and for the total volume anticipated to be sampled. If the flow
meters on the 2 instruments do not agree within 0.01 liters, then adjust the meter on the
model 90 until agreement is within 0.01 liters. After making any correction, run a full
calibration again.
4.1.2 Sample train assembly. Assemble the probe (prefilter if needed), adsorber tube, and
teflon line to the inlet of the model 90. Attach a short (8 to 10 inches) flexible line to the
outlet of model 90. Have a completely clean evacuated tedlar sample bag nearby for
collection of sample to be analyzed.
4.1.3 Pretest leak check. Stopper the inlet of the probe and place the flexible tube on the
outlet of the model 90 in a small open container of water. Turn on the sampling pump. For
a satisfactory leak check, bubbling should cease within 1 minute. If the leak check is
unsatisfactory, tighten the fittings or change parts until a satisfactory leak check is obtained.
4.1.4 Sampling train operation. Place the probe and the front portion of the adsorption tube
in the stack. If the stack has a temperature higher than ambient, allow time for the probe to
heat before starting the sample pump. Start the model 90 pump and adjust to the desired
flow, usually about 90 ml/min. After about 0.1 liter of sampling, or equivalent to the
volume of air that is displaced in the sample system before the flowmeter, remove the
flexible tube from the outlet of the model 90 and install the evacuated tedlar bag. This
assures that gaseous components are undiluted by the air originally in the sampling system.
Record requested data on the data form during the sample time. The sampling is usually
done for 1 hour with a total of 5 to 6 liters sampled. When sampling is complete, record
the precise volume sampled. The process may require different sample times or sample
volumes. (Sampling form is figure 25-8.)
4.1.5 Post test leak check. Remove the tedlar bag and replace it with the flexible tube.
Stopper the probe and operate the same as the pretest leak check specified in section 4.1.3.
If the leak test is not acceptable, invalidate the sample.
4.2 Sample recovery. The tedlar bag is ready for direct analysis on the GC. The adsorber
tube shall undergo the following 2-stage preparation:
4.2.1 Sample purge. The absorber tube is placed in the Byron model 75 oven with a clean
tedlar bag attached directly to the tube. A volume of clean dry air is passed through the
adsorber tube while holding the oven temperature at about 130 degrees Celsius. The
volume of air should be precisely the same as that sampled. This purge is necessary to
remove any CO2 on the sample tube, and the elevated temperature is needed to assure CO2
removal from any absorbed water. The tedlar bag is now ready for direct analysis on the
GC.
4.2.2 Sample digest. The absorber tube, now free of CO2 and the lighter NMOs, is now
attached to an oxidation catalyst, and another tedlar bag is attached to the outlet of the
oxidation catalyst. A volume of clean dry air equal to that sampled is passed through this
system while the temperature on the sample tube is brought up to 600 degrees Celsius. If
the sampled volume was less than 3 liters, a larger volume shall be used in the digestion to
assure completion. Usually a multiple of precisely 1.5 or 2.0 of the sampled volume is
sufficient. This third tedlar bag is now ready for direct analysis on the GC. If anything other
than CO2 is found in this bag, the model 75 oxidation catalyst is probably in need of
replacement. In this case the test would be invalid and would have to be redone.
4.3 Analysis. Each of the 3 bags is analyzed on the GC. Each bag should be analyzed as
soon as possible after being filled. At the completion of analysis, the bags shall be cleaned
by repeated fillings with either clean air or nitrogen. Before being used again, the bags shall
be checked by filling with clean air and then analyzed on the GC to assure zero
concentrations of all analyzed substances. All pertinent calibration, performance, and
operational checks in sections 4.4 and 5 of method 25 apply to the Byron system.
6. Calculations.
6.1 Nomenclature.
C1 = Concentration of sample bag, ppm C, (NMO converted to methane).
C2 = Concentration of purge bag, ppm C, (NMO converted to methane).
C3 = Concentration of digest bag, ppm C, (CO2 converted to methane).
C = Ppm C (NMO).
6.2-6.4 (Delete).
6.5 C1, C2, C3 calculated directly as: ppm C calibration gas x GC reading unknown =
ppm C GC reading calibration gas unknown 6.6 C = C1 + C2 + C3 Delete figures 25.3,
25.4, 25.9, and 25.10 from method 25. Amend figures 25.1 and 25.8 from method 25 to
read as follows:
FIGURE 25.1
SAMPLING TRAIN
FIGURE 25.1