R 336.2151
R 336.2151 Calibration gases for continuous emission monitoring systems.
Cite as Mich. Admin. Code R 336.2151
Rule 1151. (1) For nitrogen oxide monitoring systems installed on fossil fuel-fired steam
generators, the pollutant gas used to prepare calibration gas mixtures shall be nitric oxide.
(2) For sulfur dioxide monitoring systems installed on fossil fuel-fired steam generators
or sulfuric acid plants, the pollutant gas used to prepare calibration gas mixtures shall be
sulfur dioxide.
(3) Span and zero gases shall be traceable to national bureau of standards reference gases
when these reference gases are available. Every 6 months from the date of manufacture,
span and zero gases shall be reanalyzed by conducting triplicate analyses using the
reference method in appendix A of 40 C.F.R. Part 60, adopted by reference in R 336.1299,
as follows:
(a) For sulfur dioxide, use reference method 6.
(b) For nitrogen oxides, use reference method 7.
(c) For carbon dioxide and oxygen, use reference method 3. The gases may be analyzed
at less frequent intervals if longer shelf lives are guaranteed by the manufacturer.