Minn. R. 7083.4020
TEST RESULTS REPORTING REQUIREMENTS FOR PROPRIETARY TREATMENT PRODUCTS
TABLE II Treatment component/sequence category Testing results reported Category A: Designed to treat sewage with strength typical of a residential source when septic tank effluent is anticipated to be equal to or less than treatment level C (Table III, part 7083.4030) Report test results for influent and effluent sampling obtained throughout the testing period for evaluation of consistent reduction for the parameters CBOD 5 and TSS: - Average - Minimum - Median - 30-day average (each month) - Standard deviation - Maximum - Interquartile range. For bacteriological reduction performance, report fecal coliform test results of influent and effluent sampling by geometric mean from samples drawn within 30-day or monthly calendar periods, obtained from a minimum of three samples per week throughout the testing period. See part 7083.4060 . Test report must also include the individual results of all samples drawn throughout the test period. Category B: Designed to treat high-strength sewage when septic tank effluent is anticipated to be greater than treatment level C (Table III, part 7083.4030), including restaurants, grocery stores, mini-marts, group homes, medical clinics, residences, etc. Report all individual test results and full test average values of influent and effluent sampling obtained throughout the testing period for CBOD 5 , TSS, and oil and grease. Report the treatment capacity of the product tested in pounds per day for CBOD 5 . Total nitrogen and phosphorus reduction in Categories A and B Report test results on all required performance criteria according to the format prescribed in the test protocol described in Table I, part 7083.4010 .