5 CSR 25-300.070
Fire Safety Requirements
PURPOSE: This rule establishes the fire safety requirements for all license-exempt child
care facilities.
(1) These general fire safety requirements
shall be followed at all facilities:
(A) At least one (1) portable, operable
flashlight shall be accessible to staff;
(B) All flammable materials shall be stored
properly and accessible only to authorized
persons;
(C) House numbers shall be plainly visible
from the street, or the location of the facility
shall be made known to the local fire department;
(D) If child care is provided after dark,
emergency lighting with a battery back-up
shall be required;
(E) Facilities beginning operation after
July 30, 1995, shall have a minimum ceiling
height of seven feet (7') in all areas used for
child care; and
(F) Providers shall notify the nearest fire
department when the facility begins operation.
(2) These requirements for exits and doors
shall be followed at all facilities:
(A) Each floor occupied by children shall
have no less than two (2) exits remote from
each other. Exit doors shall swing in the
direction of exit travel and shall lead directly,
or through an enclosed fire-resistant stairway,
to the outside. This includes basement areas;
(B) Children shall not be permitted to sleep
above the second floor;
(C) Doors in a means of egress shall swing
in the direction of exit travel. This does not
apply to facilities caring for ten (10) or less
children;
(D) Outside doors shall not be locked to
prevent exit while the building is occupied;
(E) Every bathroom door lock or bathroom
stall door shall be designed to permit opening
from the outside in an emergency. All closet
latches shall allow children to open the doors
from the inside; and
(F) Facilities shall have smokestop partitions with a one- (1-) hour fire resistant rating between each floor. All doors providing
separation between floors shall have a fortyfive- (45-) minute fire resistant rating with an
attached self-closing device. This does not
apply to facilities caring for ten (10) or fewer
children.
(3) These requirements for detection and
extinguishment systems shall be followed at
all facilities:
(A) Each facility caring for more than ten
(10), but less than fifty (50) children at one
(1) time shall have—
1. Manual pull stations by every exit or
where designated by the fire inspector. They
shall be connected to an alarm that is audible
throughout the facility. One- (1-) room facilities that exit directly to the outside are not
subject to this requirement; and
2. At least one (1) Underwriter’s
Laboratory (UL) or Factory Mutual (FM)-
approved individual home-type detector shall
be located on each floor and in each hazardous area. The number and location of
detectors shall be determined by the fire
inspector. Detectors shall be tested monthly
and batteries changed as needed. A record
shall be kept of the dates of testing and
changing of batteries;
(B) Facilities caring for fifty (50) or more
children at one (1) time shall have a full-coverage electrical fire alarm system with battery
back-up, smoke detectors, heat sensors, and
pull stations. All equipment shall be UL- or
FM-certified;
(C) Facilities caring for more than one
hundred (100) children at one (1) time shall
have a fire alarm that is transmitted to the
local fire department or official authority;
(D) Commercial stoves, commercial cooking ranges, and deep fryers shall be equipped
with a range hood and extinguishing system
with an automatic cutoff of fuel supply, and
an exhaust system;
(E) A portable five (5) pound, 2A10BC
fire extinguisher shall be located near the
kitchen. The location shall be at the discretion of the fire inspector. Additional extinguishers may be required by the fire inspector; and
(F) Janitor closets, maintenance shops, and
boiler or furnace rooms in child care space
shall be separated from other parts of the
building with construction having at least a
one- (1-) hour fire resistant rating. The opening shall have solid core doors to close off the
area.
(4) Heating equipment shall be installed with
permanent connections and proper ventilation.
(A) Space heaters, floor furnaces, wood
burning stoves, and fireplaces shall have a
noncombustible guard or partition to prevent
children from touching or tampering with
them.
(B) Unvented gas and oil heaters shall not
be used.
(C) All gas and electrical heating equipment shall be equipped with thermostatic
controls. All hot water heaters shall have a
temperature/pressure relief valve, be vented
properly, and equipped with thermostatic
controls. The drain line on the pressure relief
valve shall extend to approximately six inches (6") above the floor.
(D) Only commercially manufactured heating equipment shall be used.
(5) Fire and tornado drills shall be conducted
at least every three (3) months and shall
include all children in care. Unscheduled
drills shall be held at the discretion of the
state fire marshal or department. Each fire
drill shall include a complete evacuation of
all persons from the building.
(A) An emergency plan for fires and tornadoes shall be posted conspicuously and shall
include the route for the drills and special
instructions for nonambulatory infants and
children.
(B) A written record shall be kept of the
dates and types of drills conducted.
(6) Fire safety inspections of license-exempt
facilities may be delegated to local fire districts if the standards employed for inspections are equivalent to those in this rule.
AUTHORITY: section 161.092, RSMo 2016,
and section 210.252, RSMo Supp. 2021.*
This rule was previously filed as 19 CSR 4060.080. Original rule filed Dec. 1, 1994,
effective July 30, 1995. Changed to 19 CSR
30-60.080 July 30, 1998. Emergency amendment filed March 1, 2000, effective March 11,
2000, expired Sept. 6, 2000. Amended: Filed
March 1, 2000, effective Aug. 30, 2000.
Moved to 5 CSR 25-300.070, effective Aug.
30, 2021. Amended: Filed Oct. 6, 2021, effective May 30, 2022.
*Original authority: 161.092, RSMo 1963, amended
1973, 2002, 2003, 2013, 2014, and 210.252, RSMo 1993,
amended 1999, 2019, 2020, 2021.