5 CSR 25-400.086
Fire Safety
PURPOSE: This rule establishes the fire safety requirements for
family day care homes.
(1) The following definitions shall be used in interpreting this
rule:
(A) Alterations are changes made to the structure or floor
plan of the facility by removing or adding walls and doors or
adding space;
(B) Dead-end is a corridor or hallway with no exit at the end
that causes occupants to retrace their path to reach an exit;
(C) Exit is the portion of a means of egress that is separated
from all other areas of the building or structure by construction
or equipment required to provide a protected way of travel
to the exit discharge. Exits include exterior exit doors,
exit passageways, horizontal exits, separated exit stairs, and
separated exit ramps;
(D) Exit access is the portion of a means of egress that leads
to an exit;
(E) Exit discharge is the portion of a means of egress between
the termination of an exit and a public way;
(F) Fire barrier is a structural element, either vertical or
horizontal, such as a wall or floor assembly that is designed
and constructed with a specified fire resistance rating to limit
the spread of fire and restrict the movement of smoke. Such
barriers may have protected openings;
(G) Fire resistance rating is the length of time in minutes or
hours that materials or structural elements can withstand fire
exposure;
(H) Flame resistant material is the property of material or
their structural elements that prevents or retards the passage
of excessive heat, hot gases, or flames under the conditions in
which they are used;
(I) Flame retardant is a chemical applied to material or other
substance that is designed to retard ignition or the spread of
fire;
(J) Interior finish includes the interior wall and ceiling finish,
and interior floor finish;
(K) Level exit discharge is a horizontal plane that is located
from the point at which an exit terminates and the exit
discharge begins. The horizontal plane shall not vary more
than two inches (2”) in rise or fall;
(L) Level is the portion of a building included between the
upper surface of a floor and the ceiling above it, or any upper
surface of a floor and the ceiling above it that is separated by
more than five (5) steps on a stairway;
(M) Means of egress is a continuous and unobstructed way of
travel from any point in a building or structure to a public way.
A means of egress consists of three (3) distinct parts: the exit
access, the exit, and the exit discharge;
AND SECONDARY EDUCATION
(N) Mixed occupancy is when a family day care home is
located in the same building or structure as another occupancy.
This may include a business or place of assembly;
(O) Public way is an area such as a street or sidewalk that is
open to the outside and is used by the public for moving from
one location to another;
(P) Remote exit or means of egress is when two (2) exits or
two (2) exit access doors are required. Each exit or exit access
door shall be placed at a distance apart equal to at least
one-half (1/2) the length of the maximum overall diagonal
dimension of the building or area to be used;
(Q) Self-closing means to be equipped with an approved
device that will ensure closing after having been opened;
(R) Smoke barrier is a structural element, either vertical or
horizontal, such as a wall, floor, or ceiling assembly that is
designed and constructed to restrict the movement of smoke.
A smoke barrier may or may not have a fire resistance rating;
and
(S) Supervised automatic sprinkler system is a system with
the initiating devices monitored by the fire alarm control
panel. This may include switches used to monitor the position
of valves, a low air pressure switch, a water flow switch, and a
tamper switch.
(2) General Requirements.
(A) The Missouri Division of Fire Safety shall inspect the
facility annually for the capacity specified on the license
application and the fire inspection request. The inspection
shall include a determination of whether or not the facility
is approved for overlap care as provided in 19 CSR 30-61.155
Overlap Care of Children.
(B) At least one (1) portable, operable flashlight for each
staff member shall be located on each level of the home and
accessible to staff in the event of power failure.
(C) Child care staff shall conduct at least one (1) fire drill each
month and a disaster drill at least every three (3) months. The
disaster drills shall include tornado drills. The provider shall
maintain a written record at the facility of the date, type of
drill, time required to evacuate the building, and number of
children present during the drill.
1. Unscheduled drills may be held at the fire inspector’s
discretion.
2. A full evacuation of the home may be postponed during
severe weather.
3. An evacuation/emergency plan for fires and tornadoes
that is approved by the fire inspector shall be posted in the
home in a central location and be visible to all occupants.
The plan shall include special instructions for infants and
nonambulatory children.
4. Fire drills shall be conducted as follows:
A. Drills shall simulate an actual fire condition;
B. The children shall not obtain clothing or other items
after the alarm has sounded;
C. The children shall proceed to a predetermined
location outside the building that is sufficiently remote to
avoid fire danger, interference with fire department operations,
or confusion among different groups of children; and
D. Groups shall remain in place until a recall to the
building is issued or the children are dismissed.
(D) Children shall have no access to areas of the building that
do not meet fire safety requirements.
(E) All flammable or combustible liquids, matches, lighters,
or other hazardous items shall be stored so they are inaccessible
to the children.
(F) The house numbers shall be plainly visible from the street
in case of emergency.
(G) Housekeeping practices that ensure fire safety shall be
maintained daily.
(H) Stairways, walks, ramps, and porches shall be kept free
of ice and snow.
(I) The provider shall immediately report any fire in the
family day care home to the Office of the State Fire Marshal
and the Department of Health, Bureau of Child Care Safety and
Licensure.
(J) No fresh-cut Christmas trees shall be used unless they are
treated with a flame resistant material. Documentation of the
treatment shall be on file at the facility and available for review
by the fire inspector.
(K) The Division of Fire Safety may make additional
requirements that provide adequate life safety protection if it
is determined that the safety of the occupants is endangered.
Every building or structure shall be constructed, arranged,
equipped, maintained, and operated to avoid danger to the
lives and safety of its occupants from fire, smoke, fumes, or
resulting panic during the period of time necessary for escape
from the building.
(L) Mobile homes manufactured after November 27, 1973,
shall comply with the Missouri Public Service Commission,
regulations for mobile home tie-down systems. Manufactured
homes shall comply with section 700.070, RSMo 1994, regarding
tie-down systems.
(M) The latest edition of the National Fire Protection
Association (NFPA), Chapter 101, Life Safety Code, shall prevail
in the interpretation of this rule.
(N) When the licensed capacity increases, hours of care
change, alterations are completed, or other changes occur that
affect fire safety, the provider shall meet all the requirements
of this rule unless otherwise excepted by the Division of Fire
Safety.
(O) Facilities that were licensed and areas approved for child
care prior to the effective date of this rule shall have ceilings
at least seven feet (7’) in height. Facilities initially licensed and
areas initially approved for child care on or after the effective
date of this rule shall meet all the requirements of this rule
and shall have ceilings at least seven feet, six inches (7’6”) in
height. If alterations are made in facilities licensed prior to
the effective date of this rule, those facilities shall meet all
the requirements of this rule and shall have ceilings at least
seven feet, six inches (7’6”) in height in the altered space. The
fire inspector may make an allowance for the installation of
ductwork and plumbing.
(P) Facilities served by a volunteer or membership fire
department shall be a member in good standing with the
fire department. A copy of the membership or receipt for
membership shall be on file at the facility and available for
review.
(Q) Clothes dryers shall be vented and maintained properly.
(3) Mixed Occupancies.
(A) In addition to meeting all the requirements of this rule,
family day care homes initially licensed and areas initially
approved for child care on or after the effective date of this
rule, shall meet the following requirements. If alterations
are made in facilities licensed prior to the effective date of
this rule, those facilities shall meet these requirements in the
altered space—
1. When a facility is located in a building containing mixed
occupancies, the other occupancies shall be separated from the
family day care home by at least a one (1)-hour fire barrier; and
2. In facilities in apartment buildings, when both exit
accesses exit into the same corridor, the corridor shall be
protected throughout by a fire barrier with at least a one (1)-
hour fire resistance rated construction. All doors that open into
the corridor shall be at least thirty-two inches (32”) wide, have
a twenty (20)-minute fire resistance rating, and be self-closing.
(4) Exiting and Means of Egress.
(A) Each level occupied by children shall have at least two
(2) remotely located means of egress. Each door opening in a
means of egress shall be at least twenty-eight inches (28”) wide.
In new construction, each door opening shall be a minimum of
thirty-two inches (32”) wide.
(B) Each room over three hundred (300) square feet in size
that is used for day care shall have at least two (2) means of
egress. At least one (1) means of egress shall be a door or
stairway providing a means of unobstructed travel through the
home to the outside of the building at street or ground level.
The second means of egress may be a window in accordance
with 19 CSR 30-61.086(5) Fire Safety.
(C) No room or space that is accessible only by a ladder,
folding stairs, overhead door, or through a trap door shall be
occupied at any time.
(D) Facilities that use a garage as a second exit shall have no
flammable or combustible liquids stored in the garage unless
approved by the fire inspector. Overhead garage doors are not
recognized as exit doorways.
(E) Automobiles shall not be stored in the garage during day
care hours if there is an exit through the garage, unless the
fire inspector determines that there is sufficient space for safe
evacuation.
(F) No door in a means of egress shall be locked against
egress travel when the building is occupied. Locking devices
that impede or prohibit egress or that cannot be disengaged
easily shall not be used. Dead bolt locks that require a key to
unlock the door from the inside shall not be used. Locking or
latching devices installed on doors shall not be located higher
than fifty inches (50”) above the finished floor.
(G) Where two (2) exits or exit access doors are required, they
shall be remotely located from each other.
(H) Closet door latches shall be designed so children can
open the doors from the inside. Bathroom door locks shall
be designed to permit opening of the door from the outside
in an emergency. The opening device or key shall be readily
accessible to the staff.
(I) Stairways, landings, and ramps shall be free of all objects.
(J) Dead-ends as defined by 19 CSR 30-61.086(1)(B) Fire Safety
shall not exceed twenty feet (20’).
(5) Windows for Rescue and Ventilation.
(A) In addition to meeting all the requirements of this rule,
facilities initially licensed and areas initially approved for child
care on or after the effective date of this rule, shall meet the
following requirements. If alterations are made in facilities
licensed prior to the effective date of this rule, those facilities
shall meet these requirements in the altered space—
1. Every room or space greater than three hundred (300)
square feet used by children shall have at least one (1) outside
window for emergency rescue and ventilation. The window
shall be operable from the inside without the use of tools
and shall provide a clear opening of at least twenty inches
(20”) wide, twenty-four inches (24”) in height. The total clear
opening space shall be no less than 5.7 square feet in size. The
bottom of the opening shall be no more than forty-four inches
(44”) above the floor and any latching device shall be operated
easily. The clear opening shall be a rectangular solid, with a
minimum width and height that provides the required 5.7
square feet opening and a minimum depth of twenty inches
(20”) to allow passage through the opening. The windows shall
be accessible by the fire department and shall open into an
area having access to a public way. This does not apply when
the room or space has a door leading directly to the outside of
the building; and
2. No windows shall have bars or any other items placed
over them in a stationary manner that would impede a rescue
or evacuation attempt.
(6) Level of Exit Discharge.
(A) Areas used for day care shall not be located more than
one (1) level below ground level.
(B) In addition to meeting all the requirements of this rule,
facilities initially licensed and areas initially approved for child
care on or after the effective date of this rule, shall meet the
following requirements. If alterations are made in facilities
licensed prior to the effective date of this rule, those facilities
shall meet these requirements in the altered space—
1. Where children are occupying a level below or above
the level of exit discharge (basement or second floor), at least
one (1) means of egress shall be an exit discharging directly to
the outside. The vertical travel to ground level shall not exceed
eight feet (8’) for the basement and twelve feet (12’) for the
second floor; and
2. Where children are occupying a level below or above the
level of exit discharge (basement or second floor), arrangement
of means of egress shall be remote from each other.
(7) Travel Distance.
(A) The travel distance between any room door intended
as an exit access or an exit shall not exceed one hundred feet
(100’). This travel distance may be increased by fifty feet (50’)
in buildings protected throughout by a supervised automatic
sprinkler system that is approved by the fire inspector based
on the National Fire Protection Association’s Standards for
Sprinkler Systems.
(B) The travel distance between any point in a room and
an exit shall not exceed one hundred fifty feet (150’). This
travel distance may be increased by fifty feet (50’) in buildings
protected throughout by a supervised automatic sprinkler
system that is approved by the fire inspector based on the
National Fire Protection Association’s Standards for Sprinkler
Systems.
(C) The travel distance between any point in a sleeping room
and an exit access to that room shall not exceed fifty feet (50’).
(8) Emergency Lighting.
(A) Emergency lighting shall be installed if the facility is
providing nighttime care or if the fire inspector determines
that the safety of the occupants is endangered. Emergency
lights shall have a ninety (90)-minute battery backup and shall
be installed at a location determined by the fire inspector.
(9) Interior Finish.
(A) Interior wall and ceiling finishes throughout shall be
Class C as provided in the latest edition of the National Fire
Protection Association, Chapter 101, Life Safety Code. Textile
AND SECONDARY EDUCATION
materials having a napped, tufted, looped, woven, nonwoven,
or similar surface shall not be applied to walls or ceilings.
Foam plastic materials or other highly flammable or toxic
material shall not be used as an interior wall, ceiling, or floor
finish.
(B) In addition to meeting all the requirements of this rule,
facilities initially licensed and areas initially approved for child
care on or after the effective date of this rule, shall have wall
studs, ceiling joists, and floor joists that are covered with a
minimum of Class C finish with no exposed studs or joists. If
alterations are made in facilities licensed prior to the effective
date of this rule, those facilities shall meet these requirements
in the altered space.
(10) Detection and Extinguishment.
(A) Smoke detectors shall be installed in all family day care
homes.
(B) Smoke detectors shall be in good operating condition
with a functional battery installed. If the smoke detector is not
operational, the provider shall install a smoke detector that is
powered by the home’s electrical system with a nine (9)-volt
battery backup.
(C) Smoke detectors shall be installed on each level of the
home in or near all sleeping areas. Additional smoke detectors
shall be required in other rooms and areas if the fire inspector
determines that the safety of the occupants is endangered.
(D) Facilities using equipment or appliances that pose a
potential carbon monoxide risk, including homes with attached
garages, shall install a carbon monoxide detector(s). The
detector(s) shall be installed according to the manufacturer’s
instructions. The fire inspector may require additional carbon
monoxide detectors if the inspector determines that the safety
of the occupants is endangered.
1. Carbon monoxide detectors shall be in good operating
condition. If a battery-operated detector is not operational, the
provider shall install a detector that is powered by the home’s
electrical system with a battery backup.
2. If an elevated carbon monoxide level is detected during
a fire inspection, the provider shall have all gas-fired appliances
checked by a heating and air conditioning company to identify
the source of the carbon monoxide. Until the provider has
documentation on file at the facility verifying that all gas-fired
appliances were checked by a heating and air conditioning
company and are in safe working order, and the facility is
determined safe by the fire inspector, the fire inspection shall
not be approved.
3. If a level of carbon monoxide is determined that
endangers the children in care, the fire inspector shall take
measures necessary to protect the children. This may include
evacuation of the building or closing the facility. The provider
shall obtain and have on file at the facility, documentation
verifying that all gas-fired appliances were checked by a
heating and air conditioning company and are in safe working
order. The facility shall be reinspected by the fire inspector and
determined safe before the children can return to the building
or the facility can reopen.
(E) At least one (1) portable, 5 lb., 2 A-10 BC, fire extinguisher
shall be required in all facilities and located near the kitchen
or a location required by the fire inspector. Facilities using
more than one (1) level shall have an additional extinguisher
on each level.
(F) Fire extinguishers shall be installed and maintained
according to the instructions of the fire inspector and shall
be inspected and approved annually by a fire extinguisher
company. Documentation of the inspection and approval shall
be on file at the facility and available for review by the fire
inspector.
(G) In addition to meeting all the requirements of this rule,
facilities initially licensed and areas initially approved for child
care on or after the date of this rule, shall meet the following
requirements. If alterations are made in facilities licensed prior
to the effective date of this rule, those facilities shall meet these
requirements in the altered space—
1. Smoke detectors shall be powered by the home’s
electrical system and have a nine (9)-volt battery backup.
When more than one (1) smoke detector is required by the fire
inspector, the smoke detectors shall be interconnected so that
when one smoke detector activates, it causes an alarm in all
smoke detectors; and
2. Where the family day care home is located within
a building of another occupancy such as in an apartment
building or office building, any corridors serving the family
day care home shall be provided with a smoke detector(s) that
will activate the smoke detector(s) inside the family day care
home.
(H) Facilities that have a supervised automatic sprinkler
system installed shall have the system tested and approved
annually by a fire sprinkler company. A copy of the test report
and approval of the system shall be kept on file at the facility
and available for review by the fire inspector.
(11) Electrical Services.
(A) Electrical wiring shall be installed and maintained in
good working order. If the fire inspector considers the wiring
to be unsafe for the occupants or it is installed improperly, an
inspection by a licensed electrician may be required prior to
fire safety approval. The inspection by the licensed electrician
shall be based on National Fire Protection Associa-tion, Chapter
70, National Electrical Code.
(B) Protective covers or inserts for electrical receptacles shall
be installed in all areas occupied by children.
(C) Electrical extension cords shall not be used unless
approved in writing by the fire inspector.
(12) Heating, Cooling, and Air Conditioning Equipment.
(A) Unvented fuel-fired room heaters and portable electrical
space heaters shall not be used during child care hours. The
provider shall sign a compliance letter verifying that such
equipment will not be used.
(B) Facilities with a water heater over two hundred thousand
(200,000) British thermal units (Btus) per hour input or larger,
or that is heating with a boiler, shall have a valid permit from
the Division of Fire Safety posted on the premises. A copy of
the permit shall be kept on file at the Division of Fire Safety.
(C) Floor furnaces shall have noncombustible protective
guards installed around them and shall be located so they do
not block access to an exit from any area of the licensed day
care space.
(D) Heating equipment, fireplaces, and radiators in areas
occupied by children shall have partitions, screens, or other
means to protect children from hot surfaces and open flames.
If solid partitions are used, provisions shall be made to ensure
adequate air for combustion and ventilation for heating
equipment. Partitions shall be constructed of noncombustible
material and shall not obstruct exit access.
(E) Gas and electric heating equipment shall be equipped
with thermostatic controls. Gas water heaters shall have a
properly sized pressure relief valve and be vented properly by
galvanized flue pipe and screws at every joint in the pipe or by
material recommended by the manufacturer. The drip leg pipe
on the pressure relief valve shall extend to approximately six
inches (6”) above the floor.
(F) Furnace rooms shall be vented properly. Furnace flue
pipes shall be constructed of galvanized pipe or material
recommended by the manufacturer. Galvanized pipe shall be
secured by screws at every joint in the pipe.
(G) Joints in gas supply pipes shall be located outside the
furnace cabinet housing.
(H) Furnaces, water heaters and boilers shall be located
inside a fire resistant room that is constructed of five-eighth
inch (5/8”) sheet rock or equivalent on the interior, exterior,
and ceiling. The room shall have a one and three-quarter
inch (1 3/4”) thick solid core door. Furnace rooms and rooms
containing water heaters shall not be required to be fire
resistive if an automatic sprinkler head is installed off the
domestic water system and a smoke detector is located directly
outside the room that is interconnected to the other smoke
detectors throughout the home.
(I) Furnace rooms and rooms containing water heaters
shall have adequate combustion air for the units. The vent
size opening for the combustion air shall be measured at
one (1) square inch per one thousand (1,000) Btu input, if the
combustion air is drawn from inside the structure and one (1)
square inch per four thousand (4,000) Btu input if the air is
drawn from outside the structure through the attic or crawl
space. There shall be two (2) combustion air vent openings
in each furnace room. One (1) opening shall be located at the
lower level and the other at the upper level.
(J) Air conditioning, heating, ventilating ductwork, and
related equipment shall be installed safely and be in good
operating condition as determined by the fire inspector. The
fire inspector shall base this on the National Fire Protection
Association, Chapter 90A, Standard for the Installation
of Air Conditioning and Ventilating Systems; or National
Fire Protection Association, Chapter 90B, Standard for the
Installation of Warm Air Heating and Air Conditioning Systems,
as applicable.
(K) Fireplaces and wood burning stoves shall be installed
safely and operate in good working condition as determined
by the fire inspector.
(L) Flues shall be inspected and cleaned once a year, and
the provider shall have documentation of the inspection and
cleaning on file at the facility and available for review by the
fire inspector. A spark arrestor shall be installed at the chimney
outlet.
(M) In addition to meeting all the requirements of this rule,
facilities initially licensed and areas initially approved for child
care on or after the effective date of this rule, shall meet the
following requirements. If alterations are made in facilities
licensed prior to the effective date of this rule, those facilities
shall meet these requirements in the altered space—
1. Gas shut off valves shall be located next to all gas
appliances, furnaces, and water heaters;
2. If a furnace or water heater is located inside a garage, it
shall be at least eighteen inches (18”) above the finished floor
and enclosed inside a fire resistant room. The room shall be
constructed of five-eighth inch (5/8”) sheet rock on the interior
and exterior wall and interior ceiling and shall have a one and
three-quarter inch (1 3/4”) thick solid core door; and
3. Furnaces shall be equipped with an electrical fused
switch to protect the unit from electrical overloading and to
disconnect the electrical supply.
(13) Equivalency Concepts.
(A) Nothing in this rule is intended to prevent the use of
systems, methods, or devices of equivalent or superior quality,
strength, fire resistance, effectiveness, durability, and safety
as alternatives required by this rule. These alternatives may
be used only if technical documentation to demonstrate
equivalency and the system, method, or device is submitted
and approved by the Missouri Division of Fire Safety.
AUTHORITY: section 210.221.1(3), RSMo Supp. 1998.* This rule
originally filed as 19 CSR 30-61.086. Original rule filed Feb. 18,
1999, effective Sept. 30, 1999. Moved to 5 CSR 25-400.086, effective
Aug. 30, 2021.
*Original authority: 210.221.1(3), RSMo 1949, RSMo 1955, 1987, 1993, 1995.