10 CSR 10-5.350
Control of Emissions From Manufacture of Synthesized Pharmaceutical Products
PURPOSE: This rule restricts volatile organic compound emissions from the manufacture
of synthesized pharmaceutical products.
(1) Application.
(A) This rule shall apply throughout St.
Louis City and Jefferson, St. Charles,
Franklin and St. Louis Counties.
(B) This rule applies to all synthesized
pharmaceutical manufacturing installations.
(C) This rule applies only to operations
including reactors, distillation units, dryers,
storage of volatile organic compounds
(VOCs), transfer of VOC, extraction equipment, filters, crystallizers and centrifuges
that individually and uncontrolled would emit
fifteen pounds (15 lbs.) per day or more of
VOC.
(D) This rule does not apply to operations
used exclusively for chemical or physical
analysis or determination of product quality
and commercial acceptance (such as research
facilities, pilot plant operations and laboratories) unless—
1. The operation is an integral part of
the production process; or
2. The emissions from the operation
exceed three hundred sixty-three kilograms
(363 kg) (eight hundred 800 lbs.) in any calendar month.
(2) Definitions of certain terms specified in
this rule may be found in 10 CSR 10-6.020.
(3) Operating Equipment and Operating
Procedure Requirements.
(A) The owner or operator of a synthesized
pharmaceutical manufacturing facility subject
to this rule shall control the VOC emissions
from all reactors, distillation operations,
crystallizers, centrifuges and vacuum dryers
by the use of surface condensers or equivalent
controls.
1. If surface condensers are used, with
vapor pressures as measured at twenty
degrees Celsius (20 °C), the condenser outlet
gas temperature must not exceed—
A. Minus twenty-five degrees Celsius
(-25 °C), when condensing VOC of vapor
pressure greater than 40.0 kilopascals (kPa)
(5.8 psi);
B. Minus fifteen degrees Celsius
(-15 °C), when condensing VOC of vapor
pressure greater than 20.0 kPa (2.9 psi);
C. Zero degrees Celsius (0 °C), when
condensing VOC of vapor pressure greater
than 10.0 kPa (1.5 psi);
D. Ten degrees Celsius (10 °C),
when condensing VOC of vapor pressure
greater than 7.0 kPa (1.0 psi); or
E. Twenty-five degrees Celsius
(25 °C), when condensing VOC of vapor
pressure greater than 3.50 kPa (0.5 psi).
2. If equivalent controls are used, the
VOC emissions must be reduced by an
amount equivalent to the reductions achieved
in paragraph (3)(A)1. Equivalent controls
may not be used unless approved by the director.
(B) The owner or operator of a synthesized
pharmaceutical manufacturing installation
subject to this rule shall reduce the VOC
emissions from all air dryers and production
equipment exhaust systems—
1. By at least ninety percent (90%) if
emissions are one hundred fifty (150) kg/day,
Specific to the St. Louis Metropolitan Area
three hundred thirty (330) lbs./day or more of
VOC; or
2. To fifteen (15) kg/day thirty-three
(33) lbs./day or less if emissions are less than
one hundred fifty (150) kg/day, three hundred
thirty (330) lbs./day of VOC.
(C) The owner or operator of a synthesized
pharmaceutical manufacturing installation
subject to this rule shall—
1. Provide a vapor recovery system or
equivalent control that is ninety percent
(90%) or more effective in reducing daily
average emissions from truck or railcar deliveries to storage tanks with capacities greater
than seven thousand five hundred (7,500)
liters (two thousand (2,000) gallons) that
store VOC with vapor pressures greater than
28.0 kPa (4.1 psi) at twenty degrees Celsius
(20 °C); and
2. Install pressure/vacuum conservation
vents set at ±0.2 kPa on all storage tanks that
store VOC with vapor pressures greater than
10.0 kPa (1.5 psi) at twenty degrees Celsius
(20 °C), unless a more effective control system is used.
(D) The owner or operator of a synthesized
pharmaceutical manufacturing installation
subject to this rule shall enclose all centrifuges, rotary vacuum filters and other filters having an exposed liquid surface, where
the liquid contains VOC and exerts a total
VOC vapor pressure of 3.50 kPa (0.5 psi) or
more at twenty degrees Celsius (20 °C).
(E) The owner or operator of a synthesized
pharmaceutical manufacturing installation
subject to this rule shall install covers on all
in-process tanks containing a VOC at any
time. These covers must remain closed,
unless production, sampling, maintenance or
inspection procedures require operator
access.
(F) The owner or operator of a synthesized
pharmaceutical manufacturing installation
subject to this rule shall repair all leaks from
which a liquid containing VOC can be
observed running or dripping. The repair
shall be completed the first time the equipment is off-line for a period of time long
enough to complete the repair.
(4) Compliance Determination and Record
Keeping.
(A) Compliance with this rule in subsections (3)(A) and (B) and paragraph (3)(C)1.
shall be determined by the testing methods
referenced in 10 CSR 10-6.030(14)(A).
(B) Owners or operators utilizing add-on
control technology shall monitor and record
the following parameters continuously while
the affected equipment is in operation:
1. Exhaust gas temperature of all incinerators;
2. Temperature rise across a catalytic
incinerator bed;
3. VOC breakthrough on a carbon
adsorption unit;
4. Exit stream temperature on all condensers; and
5. Any other monitoring device requested by the director.
(C) Records shall be kept on production
rates sufficient to determine daily VOC emissions and any equipment test results performed in conjunction with this rule.
(D) Records of all information requested in
subsection (4)(B) shall be kept for a period of
not less than two (2) years and all these
records shall be made available to the director
upon his/her request.
(5) Compliance Dates.
(A) The owner or operator of a synthesized
pharmaceutical manufacturing installation
subject to this rule must submit a final control plan to the director by December 31,
1980, for his/her approval. This plan must
include the following:
1. A detailed plan of process modifications; and
2. A time schedule for compliance containing increments of progress and a final
compliance date.
(B) Compliance with this rule shall be
accomplished by any installation as expeditiously as practicable, but in no case shall
final compliance extend beyond December
31, 1982.
AUTHORITY: section 643.050, RSMo 1994.*
Original rule filed March 13, 1980, effective
Sept. 12, 1980. Amended: Filed Oct. 4,
1988, effective March 11, 1989.
*Original authority: 643.050, RSMo 1965, amended
1972, 1992, 1993.