10 CSR 10-5.550
Control of Volatile Organic Compound Emissions From Reactor Processes and Distillation Operations Processes in the Synthetic Organic Chemical Manufacturing Industry
PURPOSE: This rule limits volatile organic
compound emissions from reactor processes
and distillation operations in the St. Louis
1997 eight (8)-hour ozone nonattainment
area.
PUBLISHER’S NOTE: The secretary of state
has determined that the publication of the
entire text of the material which is incorporated by reference as a portion of this rule would
be unduly cumbersome or expensive. This
material as incorporated by reference in this
rule shall be maintained by the agency at its
headquarters and shall be made available to
the public for inspection and copying at no
more than the actual cost of reproduction.
This note applies only to the reference material. The entire text of the rule is printed here.
(1) Applicability.
(A) The provisions of this rule apply to any
vent stream originating from a process unit
with a reactor process or distillation operation located in St. Louis City and Jefferson,
St. Charles, Franklin and St. Louis Counties
existing on February 29, 2000.
(B) Exemptions from the provisions of this
rule are as follows:
1. Any reactor process or distillation
operation that is designed and operated in a
batch mode is not subject to the provisions of
this rule;
2. Any reactor process or distillation
operation that is part of a polymer manufacturing operation is not subject to the provisions of this rule;
3. Any reactor process or distillation
operation operating in a process unit with a
total design capacity of less than one (1) gigagram (1,100 tons) per year for all chemicals
produced within that unit is not subject to the
provisions of this rule except for the reporting
and record keeping requirements listed in
subsection (4)(D) of this rule; and
4. Any vent stream for a reactor process
or distillation operation with a flow rate less
than 0.0085 standard cubic meter per minute
or a total volatile organic compound (VOC)
concentration less than five hundred (500)
parts per million by volume is not subject to
the provisions of this rule except for the performance testing requirement listed in subparagraph (3)(B)3.B., paragraph (3)(B)9. and
the reporting and record keeping requirements listed in subsection (4)(C) of this rule.
(C) In the event that other rules in Title 10
Division 10 of the Code of State Regulations
are also applicable to reactor processes and
distillation operation processes in the chemical manufacturing industry, the more stringent rule applies.
(2) Definitions.
(A) Batch mode—A noncontinuous operation or process in which a discrete quantity or
batch of feed is charged into a process unit
and distilled or reacted at one time.
(B) Boiler—Any enclosed combustion
device that extracts useful energy in the form
of steam.
(C) By compound—By individual stream
components, not carbon equivalents.
(D) Continuous recorder—A data recording device recording an instantaneous data
value at least once every fifteen (15) minutes.
(E) Distillation operation—An operation
separating one (1) or more feed stream(s) into
two (2) or more exit stream(s), each exit
stream having component concentration different from those in the feed stream(s). The
separation is achieved by the redistribution of
the components between the liquid- and
vapor-phase as they approach equilibrium
within the distillation unit.
(F) Distillation unit—A device or vessel in
which distillation operations occur, including
all associated internals (such as trays or packing) and accessories (such as reboiler, condenser, vacuum pump, stream jet, etc.), plus
any associated recovery system.
(G) Flame zone—The portion of the combustion chamber in a boiler occupied by the
flame envelope.
(H) Flow indicator—A device that indicates whether gas flow is present in a vent
stream.
(I) Halogenated vent stream—Any vent
stream determined to have a total concentration of halogen atoms (by volume) contained
in organic compounds of two hundred (200)
parts per million by volume or greater determined by Method 18 of 40 CFR part 60,
Appendix A, as specified in 10 CSR 106.030(22), or other test or data validated by
Method 301 of 40 CFR part 63, Appendix A,
or by engineering assessment or process
knowledge that no halogenated organic compounds are present. Method 301 of 40 CFR
63, Appendix A, promulgated as of July 1,
2018 is hereby incorporated by reference in
this rule, as published by the Office of the
Federal Register. Copies can be obtained
from the U.S. Publishing Office Bookstore,
710 N. Capitol Street NW, Washington DC
20401. This rule does not incorporate any
subsequent amendments or additions. For
example, one hundred fifty (150) parts per
million by volume of ethylene dichloride
would contain three hundred (300) parts per
million by volume of total halogen atoms.
(J) Incinerator—Any enclosed combustion
device that is used for destroying organic
compounds. Auxiliary fuel may be used to
heat waste gas to combustion temperatures.
Any energy recovery section present is not
physically formed into one section; rather,
the energy recovery system is a separate section following the combustion section and the
two are joined by ducting or connections that
carry fuel gas.
(K) Primary fuel—The fuel that provides
the principal heat input to the device. To be
considered primary, the fuel must be able to
sustain operation without the addition of
other fuels.
(L) Process heater—A device that transfers
heat liberated by burning fuel to fluids contained in tubes, including all fluids except
water that is heated to produce steam.
(M) Process unit—Equipment assembled
and connected by pipes or ducts to produce,
as intermediates or final products, one or
more
SOCMI
chemicals
included
in
Appendix A of Control of Volatile Organic
Compound
Emissions
from
Reactor
Processes
and
Distillation
Operations
Processes in the Synthetic Organic Chemical
Manufacturing Industry, EPA-450/4-91-031.
Appendix A of Control of Volatile Organic
Compound
Emissions
from
Reactor
Processes
and
Distillation
Operations
Processes in the Synthetic Organic Chemical
Manufacturing Industry, EPA-450/4-91-031
promulgated August 1993 is hereby incorporated by reference in this rule. Copies can be
obtained from the National Service Center
for Environmental Publications (NSCEP),
PO Box 42419, Cincinnati, Ohio 452420419. This rule does not incorporate any subsequent amendments or additions. A process
unit can operate independently if supplied
with sufficient feed or raw materials and sufficient product storage facilities.
(N) Product—Any compound or SOCMI
chemical (see Appendix A of Control of
Specific to the St. Louis Metropolitan Area
Volatile Organic Compound Emissions from
Reactor Processes and Distillation Operations
Processes in the Synthetic Organic Chemical
Manufacturing Industry, EPA-450/4-91-031,
as incorporated by reference in subsection
(2)(M) of this rule) that is produced as that
chemical for sales as a product, by-product,
co-product, or intermediate or for use in the
production of other chemicals or compounds.
(O) Reactor processes—Unit operations in
which one (1) or more chemicals, or reactants other than air, are combined or decomposed in such a way that their molecular
structures are altered and one or more new
organic compounds are formed.
(P) Recovery device—An individual unit of
equipment, such as an adsorber, carbon
adsorber, or condenser, capable of and used
for the purpose of recovering chemicals for
use, reuse, or sale.
(Q) Recovery system—An individual
recovery device or series of such devices
applied to the same vent stream.
(R) Total organic compounds or “TOC”—
Those compounds measured according to the
procedures of Method 18 of 40 CFR part 60,
Appendix A. For the purposes of measuring
molar compositions as required in subparagraph (3)(B)3.D.; hourly emissions rate as
required in subparagraph (3)(B)5.D. and paragraph (3)(B)2.; and TOC concentration as
required in paragraph (4)(A)4. The definition
of TOC excluded those compounds that the
administrator designates as having negligible
photochemical reactivity. The administrator
has designated the following organic compounds negligibly reactive: methane; ethane;
1,1,1-trichloroethane; methylene chloride;
trichlorofluoromethane;
dichlorodifluoromethane; chlorodifluoromethane; trifluoromethane;
trichlorotrifluoroethane;
dichlorotetrafluoroethane; and chloropentafluoroethane.
(S) Total resource effectiveness index value
or “TRE index value”—A measure of the
supplemental total resource requirement per
unit reduction of organic hazardous air pollutants associated with a process vent stream,
based on vent stream flow rate, emission rate
of volatile organic compound, net heating
value, and corrosion properties (whether or
not the vent stream contains halogenated
compounds) as quantified by the given equations. The TRE index is a decision tool used
to determine if the annual cost of controlling
a given vent gas stream is acceptable when
considering
the
emissions
reduction
achieved.
(T) Vent stream—Any gas stream discharge directly from a distillation operation
or reactor process to the atmosphere or indirectly to the atmosphere after diversion
through other process equipment. The vent
stream excludes relief valve discharges and
equipment leaks including, but not limited to,
pumps, compressors, and valves.
(U) Definitions of certain terms specified
in this rule, other than those specified in this
rule section, may be found in 10 CSR 106.020.
(3) General Provisions.
(A) Control Requirements.
1. For individual vent streams within a
process unit with a TRE index value less than
or equal to one (1.0), the owner or operator
shall—
A. Reduce emissions of TOC (less
methane and ethane) by ninety-eight (98)
weight-percent, or to twenty (20) parts per
million by volume, on a dry basis corrected
to three percent (3%) oxygen, whichever is
less stringent. If a boiler or process heater is
used to comply with this paragraph, then the
vent stream shall be introduced into the flame
zone of the boiler or process heater; or
B. Combust emissions in a flare.
Flares used to comply with this paragraph
shall comply with the requirements of 40
CFR 60.18. 40 CFR 60.18 promulgated as of
July 1, 2018 is hereby incorporated by reference in this rule, as published by the Office
of the Federal Register. Copies can be
obtained from the U.S. Publishing Office
Bookstore, 710 N. Capitol Street NW,
Washington DC 20401. The flare operation
requirement does not apply if a process, not
subject to this rule, vents an emergency relief
discharge into a common flare header and
causes the flare servicing the process subject
to this rule to be out of compliance with one
(1) or more of the provisions of the flare
operation rule.
2. For each individual vent stream(s)
within a process unit with a TRE index value
greater than one (1.0), the owner or operator
shall maintain vent stream parameters that
result in a calculated total resource effectiveness greater than one (1.0) without the use of
a volatile organic compound control device.
The TRE index shall be calculated at the outlet of the final recovery device.
(B) Total
Resource
Effectiveness
Determination, Performance Testing, and
Exemption Testing.
1. For the purpose of demonstrating
compliance with the TRE index value in paragraph (3)(A)2. of this rule, engineering
assessment may be used to determine process
vent stream flow rate, net heating value, and
TOC emission rate for the representative
operating condition expected to yield the lowest TRE index value.
A. If the TRE value calculated using
such engineering assessment and the TRE
equation in subparagraph (3)(B)6.A. of this
rule is greater than four (4.0), then it is not
recommended that the owner or operator perform the measures specified in paragraph
(3)(B)5. of this rule.
B. If the TRE value calculated using
such engineering assessment and the TRE
equation in subparagraph (3)(B)6.A. of this
rule is less than or equal to four (4.0), then it
is recommended that the owner or operator
perform the measurements specified in paragraph (3)(B)5. of this rule.
C. Engineering assessment includes,
but is not limited to, the following:
(I) Previous test results proved the
test is representative of current operating
practices at the process unit;
(II) Bench-scale or pilot-scale test
data representative of the process under representative operating conditions;
(III) Maximum flow rate specified
or implied within a permit limit applicable to
the process vent;
(IV) Design analysis based on
accepted chemical engineering principles,
measurable process parameters, or physical
or chemical laws or properties. Examples for
analytical methods include, but are not limited to:
(a) Use of material balances
based on process stoichiometry to estimate
maximum VOC concentration;
(b) Estimation of maximum flow
rate based on physical equipment design such
as pump or blower capacities;
(c) Estimation of TOC concentrations based on saturation conditions; and
(d) Estimation of maximum
expected net heating value based on the
stream concentration of each organic compound, or, alternatively, as if all TOC in the
stream were the compound with the highest
heating value; and
(V) All data, assumptions, and procedures used in the engineering assessment
shall be documented.
2. For the purpose of demonstrating compliance with the control requirements of this
rule, the process unit shall be run at representative operating conditions and flow rates during any performance test.
3. The following methods in 40 CFR
part 60, Appendix A, as specified in 10 CSR
10-6.030(22), shall be used to demonstrate
compliance with the emission limit or percent
reduction efficiency requirement listed in
subparagraph (3)(A)1.A. of this rule:
A. Method 1 or 1A, as appropriate,
for selection of the sampling sites. The control device inlet sampling site for determination of vent stream molar composition or
TOC (less methane and ethane) reduction
efficiency shall be located after the last recovery device but prior to the inlet of the control
device, prior to any dilution of the process
vent stream, and prior to release to the atmosphere;
B. Method 2, 2A, 2C, or 2D, as
appropriate, for determination of gas stream
volumetric flow rate;
C. The emission rate correction factor, integrated sampling, and analysis procedure of Method 3 to determine the oxygen
concentration (%O2d) for the purpose of
determining compliance with the twenty (20)
parts per million by volume limit. The sampling site shall be the same as that of the TOC
samples, and samples shall be taken during
the same time that the TOC samples are
taken. The TOC concentration corrected to
three percent (3%) oxygen (Cc) shall be computed using the following equation:
where:
Cc = Concentration of TOC (minus
methane and ethane) corrected to three percent (3%) O2, dry basis, parts per million by
volume;
CTOC = Concentration of TOC (minus
methane and ethane), dry basis, parts per
million by volume; and
%O2d = Concentration of oxygen, dry
basis, percent by volume;
D. Method 18 to determine the concentration of TOC (less methane and ethane)
at the outlet of the control device when determining compliance with the twenty (20) parts
per million by volume limit, or at both the
control device inlet and outlet when the
reduction efficiency of the control device is to
be determined.
(I) The minimum sampling time for
each run shall be one (1) hour in which either
an integrated sample or four (4) grab samples
shall be taken. If grab sampling is used then
the samples shall be taken at fifteen (15)-
minute intervals.
(II) The emission reduction (R) of
TOC (less methane and ethane) shall be
determined using the following equation:
Ei – Eo
R = × 100
Ei
where:
R = Emission reduction, percent by
weight.
Ei = Mass rate of TOC (minus methane
and ethane) entering the control device, kilogram TOC per hour.
Eo = Mass rate of TOC (minus methane
and ethane) discharged to the atmosphere,
kilogram TOC per hour.
(III) The mass rates of TOC (Ei, Eo)
shall be computed using the following equations:
n
Ei = K2 (∑ CijMij) Qi
j=1
; and
n
Eo = K2 (∑ CojMoj) Qo
j=1
where:
Cij, Coj = Concentration of sample component “j” of the gas stream at the inlet and
outlet of the control device, respectively, dry
basis, parts per million by volume;
Mij, Moj = Molecular weight of sample
component “j” of the gas stream at the inlet
and outlet of the control device, respectively,
grams per gram-mole;
Qi, Qo = Flow rate of gas stream at the
inlet and outlet of the control device, respectively, dry standard cubic meters per minute;
K2 = 2.494 × 10-6 (liters per minute)
(gram-mole per standard cubic meter)(kilogram per gram)(minute per hour), where
standard temperature for (gram-mole per
standard cubic meter) is twenty degrees
Celsius (20 °C); and
n = Number of components in the
sample.
(IV) The TOC concentration (CTOC) is
the sum of the individual components and
shall be computed for each run using the following equation:
n
CTOC = ∑ Cj
j=1
where:
CTOC = Concentration of TOC (minus
methane and ethane), dry basis, parts per
million by volume;
Cj = Concentration of sample component “j”, dry basis, parts per million by volume; and
n = Number of components in the sample;
and
E. When a boiler or process heater
with a design heat input capacity of forty-four
(44) megawatts or greater, or a boiler or process heater into which the process vent
stream is introduced with the primary fuel, is
used to comply with the control requirements, an initial performance test is not
required.
4. When a flare is used to comply with
the control requirements of this rule, the flare
shall comply with the requirements of 40
CFR part 60.18.
5. The following test methods shall be
used to determine compliance with the TRE
index value:
A. Method 1 or 1A, as appropriate,
for selection of the sampling site.
(I) The sampling site for the vent
stream molar composition determination and
flow rate prescribed in subparagraph
(3)(B)5.B. and subparagraph (3)(B)5.C. of
this rule shall be, except for the situations
outlined in part (3)(B)5.A.(II) of this rule,
after the final recovery device, if a recovery
system is present, prior to the inlet of any
control device, and prior to any post-reactor
or post-distillation unit introduction of halogenated compounds into the process vent
stream. No traverse site selection method is
needed for vents smaller than ten (10) centimeters in diameter.
(II) If any gas stream other than the
reactor or distillation vent stream is normally
conducted through the final recovery
device—
(a) The sampling site for vent
stream flow rate and molar composition shall
be prior to the final recovery device and prior
to the point at which any nonreactor or
nondistillation stream or stream from a nonaffected reactor or distillation unit is introduced. Method 18 shall be used to measure
organic compound concentrations at this site;
(b) The efficiency of the final
recovery device shall be determined by measuring the organic compound concentrations
using Method 18 at the inlet to the final
recovery device after the introduction of all
vent streams and at the outlet of the final
recovery device; and
(c) The efficiency of the final
recovery device determined according to subpart (3)(B)5.A.(II)(b) of this rule shall be
applied to the organic compound concentrations measured according to subpart
(3)(B)5.A.(II)(a) of this rule to determine the
concentrations of organic compounds from
the final recovery device attributable to the
reactor or distillation vent stream. The resulting organic compound concentrations are
then used to perform the calculations outlined
in subparagraph (3)(B)5.D. of this rule;
B. The molar composition of the vent
stream shall be determined as follows:
(I) Method 18 to measure the concentration of organic compounds including
those containing halogens; and
(II) ASTM D1946-90(2015)e1, as
specified in 10 CSR 10-6.040(16), to measure the concentration of carbon monoxide
and hydrogen;
C. The volumetric flow rate shall be
Cc = CTOC ×
17.9
20.9 – %O2d )
(
Specific to the St. Louis Metropolitan Area
determined using Method 2, 2A, 2C, or 2D,
as appropriate;
D. The emission rate of TOC (minus
methane and ethane), (ETOC), in the vent
stream shall be calculated using the following
equation:
n
ETOC = K2 ∑ CjMjQs
j=1
where:
ETOC = Emission rate of TOC (minus
methane and ethane) in the sample, kilograms
per hour;
K2 = Constant, 2.494 × 10-6 (liters per
parts per million)(gram-moles per standard
cubic meter)(kilogram per gram)(minute per
hour), where standard temperature for (grammole per standard cubic meter)(g-mole/scm)
is twenty degrees Celsius (20 °C);
Cj = Concentration of compound “j”,
on a dry basis, in parts per million as measured by Method 18, as indicated in subparagraph (3)(B)3.C. of this rule;
Mj = Molecular weight of sample “j”,
grams per gram-mole;
Qs = Vent stream flow rate (standard
cubic meters per minute) at a temperature of
twenty degrees Celsius (20 °C); and
n = Number of components in the
sample;
E. The total process vent stream concentration (by volume) of compounds containing halogens (parts per million by volume, by compound) shall be summed from
the individual concentrations of compounds
containing halogens which were measured by
Method 18; and
F. The net heating value of the vent
stream shall be calculated using the equation:
n
HT = K1 ∑ CjHj (1 – Bws)
j=1
where:
HT = Net heating value of the sample
(megajoule per standard cubic meter), where
the net enthalpy per mole of vent stream is
based on combustion at twenty-five degrees
Celsius (25 °C) and seven hundred sixty
(760) millimeters of mercury, but the standard temperature for determining the volume
corresponding to one mole is twenty degrees
Celsius (20 °C), as in the definition of Qs
(vent stream flow rate);
K1 = Constant, 1.740 × 10-7 (parts per
million)-1 (gram-mole per standard cubic
meter), (megajoule per kilocalorie), where
standard temperature for (gram-mole per
standard cubic meter) is twenty degrees
Celsius (20 °C);
Bws = Water vapor content of the vent
stream, proportion by volume: except that if
the vent stream passes through a final stream
jet and is not condensed, it shall be assumed
that Bws =0.023 in order to correct to 2.3
percent moisture;
Cj = Concentration on a dry basis of
compound “j” in parts per million, as measured for all organic compounds by Method
18 and measured for hydrogen and carbon
monoxide by the American Society for
Testing and Materials D1946-90(2015)e1, as
specified in 10 CSR 10-6.040(16);
Hj = Net heat of combustion of compound “j”, kilocalorie per gram-mole, based
on combustion at twenty-five degrees Celsius
(25°C) and seven hundred sixty (760) millimeters of mercury. The heat of combustion
of vent stream components shall be determined using ASTM D4809-13, as specified
in 10 CSR 10-6.040(25), if published values
are not available or cannot be calculated; and
n = Number of components in the
sample.
6. The Total Resource Effectiveness
(TRE) index.
A. The TRE index value of the vent
shall be calculated using the following equation:
1
TRE = [a + b (Qs) + c (Ht) + d (ETOC)]
ETOC
where:
TRE = TRE index value;
ETOC = Hourly emission rate of TOC
(minus methane and ethane), (kilograms per
hour)
as
calculated
in
subparagraph
(3)(B)5.D. of this rule;
Qs = Vent stream flow rate standard
cubic meters per minute at a standard temperature of twenty degrees Celsius (20 °C);
HT = Vent stream net heating value
(megajoules per standard cubic meter), as
calculated in subparagraph (3)(B)5.F. of this
rule; and
a,b,c,d = Coefficients presented in Table 1.
B. The owner or operator of a vent
stream shall use the applicable coefficients in
Table 1 to calculate the TRE index value
based on a flare, a thermal incinerator with
zero percent (0%) heat recovery, and a thermal incinerator with seventy percent (70%)
heat recovery, and select the lowest TRE
index value.
C. The owner or operator of a unit
with a halogenated vent stream, determined
as any stream with a total concentration of
halogen atoms contained in organic compounds of two hundred (200) parts per million by volume or greater, shall use the applicable coefficients in Table 1 to calculate the
total resource effectiveness index value based
on a thermal incinerator and scrubber.
7. Each owner or operator of an affected
facility seeking to comply with paragraph
(3)(A)2. of this rule shall recalculate the flow
rate and TOC concentration for that affected
facility whenever process changes are made.
Examples of process changes include changes
in production capacity, feedstock type, or catalyst type, or whenever there is replacement,
removal, or addition of recovery equipment.
The flow rate and VOC concentration shall be
recalculated based on test data, or on best
engineering estimates of the effects of the
change to the recovery system.
8. Where the recalculated values yield a
TRE index <1.0, the owner or operator shall
notify the state Air Pollution Control
Program within one (1) week of the recalculation and conduct a performance test according to the methods and procedures required
by subsection (3)(B) of this rule.
9. For the purpose of demonstrating that
a process vent stream has a VOC concentration below five hundred (500) parts per million by volume, the following procedures
shall be followed:
A. The sampling site shall be selected
as specified in subparagraph (3)(B)3.A. of
this rule;
B. Method 18 or Method 25A of 40
CFR part 60, Appendix A, as specified in 10
CSR 10-6.030(22), shall be used to measure
concentration; alternatively, any other
method or data that has been validated
according to the protocol in Method 301 of
40 CFR part 63, Appendix A may be used.
(I) Where Method 18 is used, the
following procedures shall be used to calculate parts per million by volume concentration:
(a) The minimum sampling time
for each run shall be one (1) hour in which
either an integrated sample or four (4) grab
samples shall be taken. If grab sampling is
used, then the samples shall be taken at
approximately equal intervals in time, such as
fifteen (15)-minute intervals during the run;
and
(b) The concentration of TOC
(minus methane and ethane) shall be calculated using Method 18 according to subparagraph (3)(B)3.D. of this rule.
(II) Where Method 25A is used,
the following procedures shall be used to calculate parts per million by volume TOC concentration:
(a) Method 25A shall be used
only if a single VOC is greater than fifty percent (50%) of total VOC, by volume, in the
process vent stream;
(b) The process vent stream
composition may be determined by either
process knowledge, test data collected using
an appropriate EPA method or a method of
data collection validated according to the protocol in Method 301 of 40 CFR part 63,
Appendix A. Examples of information that
could constitute process knowledge include
calculations based on material balances, process stoichiometry, or previous test results
provided the results are still relevant to the
current process vent stream conditions;
(c) The VOC used as the calibration gas for Method 25A shall be the single
VOC present at greater than fifty percent
(50%) of the total VOC by volume;
(d) The span value for Method
25A shall be fifty (50) parts per million by
volume;
(e) Use of Method 25A is
acceptable if the response from the high-level
calibration gas is at least twenty (20) times
the standard deviation of the response from
the zero calibration gas when the instrument
is zeroed on the most sensitive scale; and
(f) The concentration of TOC
shall be corrected to three percent (3%) oxygen using the procedures and equation in subparagraph (3)(B)3.C. of this rule; and
C. The owner or operator shall
demonstrate that the concentration of TOC
including methane and ethane measured by
Method 25A is below two hundred fifty (250)
parts per million by volume with VOC concentration below five hundred (500) parts per
million by volume to qualify for the low concentration exclusion.
(C) Monitoring Requirements.
1. The owner or operator of an affected
facility that uses an incinerator to seek to
comply with the TOC emission limit specified under subparagraph (3)(A)1.A. of this
rule shall install, calibrate, maintain, and
operate according to manufacturer’s specifications: a temperature monitoring device
equipped with a continuous recorder and having a minimum accuracy of plus or minus one
percent (± 1%) of the temperature being
measured expressed in degrees Celsius or
plus or minus (±) 0.5 °C, whichever is more
accurate.
A. Where an incinerator other than a
Coefficients for Total Resource
Effectiveness for Nonhalogenated and
Halogenated Vent Streams
Values of Coefficients
Values of Coefficients
Type of Stream
Control Device Basis
a
b
c
d
Values of Coefficients
Nonhalogenated
Flare
2.129
0.183
-0.005
0.359
Thermal incinerator
0 percent heat recovery
3.075
0.021
-0.037
0.018
Thermal incinerator
70 Percent heat recovery
3.803
0.032
-0.042
0.007
Halogenated
Thermal incinerator
and scrubber
5.470
0.181
-0.040
0.004
Values of Coefficients
Table 1
Coefficients for Total Resource Effectiveness for
Nonhalogenated and Halogenated Vent Streams
Specific to the St. Louis Metropolitan Area
catalytic incinerator is used, a temperature
monitoring device shall be installed in the
firebox.
B. Where a catalytic incinerator is
used, temperature monitoring devices shall
be installed in the gas stream immediately
before and after the catalyst bed.
2. The owner or operator of an affected
facility that uses a flare to seek to comply
with subparagraph (3)(A)1.B. of this rule
shall install, calibrate, maintain, and operate
according to manufacturer’s specifications, a
heat-sensing device, such as an ultraviolet
beam sensor or thermocouple, at the pilot
light to indicate continuous presence of a
flame.
3. The owner or operator of an affected
facility that uses a boiler or process heater
with a design heat input capacity less than
forty-four (44) megawatts to seek to comply
with subparagraph (3)(A)1.A. of this rule
shall install, calibrate, maintain, and operate
according to the manufacturer’s specifications, a temperature monitoring device in the
firebox. The monitoring device should be
equipped with a continuous recorder and have
a minimum accuracy of plus or minus one
percent (± 1%) of the temperature being
measured expressed in degrees Celsius or
plus or minus (±) 0.5 °C, whichever is more
accurate. Any boiler or process heater in
which all vent streams are introduced with
primary fuel is exempt from this requirement.
4. The owner or operator of an affected
facility that seeks to demonstrate compliance
with the total resource effectiveness index
limit specified under paragraph (3)(A)2. of
this rule shall install, calibrate, maintain, and
operate according to manufacturer’s specifications the following equipment:
A. Where an absorber is the final
recovery device in the recovery system—
(I) A scrubbing liquid temperature
monitor equipped with a continuous
recorder; and
(II) Specific gravity monitor equipped with continuous recorders;
B. Where a condenser is the final
recovery device in the recovery system, a
condenser exit (product side) temperature
monitoring device equipped with a continuous recorder and having a minimum accuracy
of plus or minus one percent (± 1%) of the
temperature being monitored expressed in
degrees Celsius or plus or minus (±) 0.5 °C,
whichever is more accurate;
C. Where a carbon adsorber is the
final recovery device unit in the recovery system, in integrating regeneration stream flow
monitoring device having a minimum accuracy of plus or minus ten percent (± 10%),
capable of recording the total regeneration
stream mass flow for each regeneration cycle;
and a carbon bed temperature monitoring
device having a minimum accuracy of plus or
minus one percent (± 1%) of the temperature
being monitored expressed in degrees Celsius
or plus or minus (±) 0.5 °C, whichever is
more accurate, and capable of recording the
carbon bed temperature after each regeneration and within fifteen (15) minutes of completing any cooling cycle; or
D. Where an absorber scrubs halogenated streams after an incinerator, boiler,
or process heater, the following monitoring
equipment is required for the scrubber—
(I) A pH monitoring device equipped with a continuous recorder; and
(II) Flow meters equipped with
continuous recorders to be located at the
scrubber influent for liquid flow and the
scrubber inlet for gas stream flow.
5. The owner or operator of a process
vent using a vent system that contains bypass
lines that could divert a vent stream away
from the combustion device used shall
either—
A. Install, calibrate, maintain, and
operate a flow indicator that provides a
record of vent stream flow at least once every
fifteen (15) minutes. The flow indicator shall
be installed at the entrance to any bypass line
that could divert the vent stream away from
the combustion device to the atmosphere; or
B. Secure the bypass line valve in the
closed position with a car-seal or a lock-andkey type configuration. A visual inspection
of the seal or closure mechanism shall be performed at least once every month to ensure
that the valve is maintained in the closed
position and the vent stream is not diverted
through the bypass line.
(4) Reporting and Record Keeping.
(A) Each reactor process or distillation
operation subject to this rule shall keep
records of the following parameters measured
during a performance test or TRE determination required under subsection (3)(B) of this
rule and required to be monitored under subsection (3)(C) of this rule.
1. Where an owner or operator subject
to the provisions of this rule seeks to demonstrate
compliance
with
subparagraph
(3)(A)1.A. of this rule through the use of
either a thermal or catalytic incinerator—
A. The average firebox temperature of
the incinerator (or the average temperature
upstream and downstream of the catalyst bed
for a catalytic incinerator), measured at least
every fifteen (15) minutes and averaged over
the same time period of the performance testing; and
B. The percent reduction of TOC
determined as specified in paragraph (3)(B)3.
of this rule achieved by the incinerator, or the
concentration of TOC (parts per million by
volume, by compound) determined as specified in paragraph (3)(B)3. of this rule at the
outlet of the control device on a dry basis
corrected to three percent (3%) oxygen.
2. Where an owner or operator subject
to the provisions of this rule seeks to demonstrate
compliance
with
subparagraph
(3)(A)1.A. of this rule through the use of a
boiler or process heater and the boiler or process heater is not exempt from these requirements due to all vent streams being introduced with primary fuel—
A. A description of the location at
which the vent stream is introduced into the
boiler or process heater; and
B. The average combustion temperature of the boiler or process heater with a
design heat input capacity of less than fortyfour (44) megawatts measured at least every
fifteen (15) minutes and averaged over the
same time period of the performance test.
3. Where an owner or operator subject
to the provisions of this rule seeks to demonstrate
compliance
with
subparagraph
(3)(A)1.B. of this rule through the use of a
smokeless flare; flare design (i.e., steamassisted, air-assisted, or nonassisted), all visible emission readings, heat content determinations, flow rate measurements, and exit
velocity determinations made during the performance test, continuous records of the flare
pilot flame monitoring, and records of all
periods of operations during which the pilot
flame is absent.
4. Where an owner or operator subject
to the provisions of this rule seeks to demonstrate compliance with paragraph (3)(A)2. of
this rule—
A. All measurements and calculations
performed to determine the flow rate, and
volatile organic compound concentration,
heating value, and TRE index value of the
vent stream; and
B. Records shall be kept of the following final recovery device parameters:
(I) Where an absorber is the final
recovery device in the recovery system, the
exit specific gravity (or alternative parameter
which is a measure of the degree of absorbing
liquid saturation, if approved, by the permitting authority), and average exit temperature
of the absorbing liquid measured at least fifteen (15) minutes and averaged over the same
time period of the performance testing (both
measured while the vent stream is normally
routed and constituted);
(II) Where a condenser is the final
recovery device in the recovery system, the
average exit (product side) temperature measured at least every fifteen (15) minutes and
averaged over the same time period of the
performance testing while the vent stream is
routed and constituted normally; or
(III) Where a carbon adsorber is
the final recovery device in the recovery system, the total stream mass or volumetric flow
measured at least every fifteen (15) minutes
and averaged over the same time period of the
performance test (full carbon bed cycle), temperature of the carbon bed after regeneration
(and within fifteen (15) minutes of completion of any cooling cycle(s)), and duration of
the carbon bed steaming cycle (all measured
while the vent stream is routed and constituted normally).
5. As an alternative to subparagraphs
(4)(A)4.A. or (4)(A)4.B. of this rule, the
concentration level or reading indicated by
the organics monitoring device at the outlet of
the absorber, condenser, or carbon adsorber,
measured at least every fifteen (15) minutes
and averaged over the same time period as the
performance testing while the vent stream is
normally routed and constituted.
(B) Each reactor process or distillation
operation seeking to comply with paragraph
(3)(A)2. of this rule shall also keep records of
the following information:
1. Any changes in production capacity,
feedstock type, or catalyst type, or of any
replacement, removal, and addition of recovery equipment or reactors and distillation
units; and
2. Any recalculation of the flow rate,
TOC concentration, or TRE value performed
according to paragraph (3)(B)7. of this rule.
(C) Each reactor process or distillation
operation seeking to comply with the flow
rate or concentration exemption level in paragraph (1)(B)4. of this rule shall keep records
to indicate that the stream flow rate is less
than 0.0085 standard cubic meters per minute
or the concentration is less than five hundred
(500) parts per million by volume.
(D) Each reactor process or distillation
operation seeking to comply with the production capacity exemption level of one (1) gigagram per year shall keep records of the
design production capacity and changes in
equipment or process operation that may
affect design production capacity to the
affected process unity.
(E) All records must be kept on-site for a
period of five (5) years and made available to
the department upon request.
(5) Test Methods. See section (3) of this rule
for applicable test methods.
AUTHORITY: section 643.050, RSMo 2016.*
Original rule filed July 15, 1999, effective
Feb. 29, 2000. Amended: Filed March 20,
2019, effective Jan. 30, 2020.
*Original authority: 643.050, RSMo 1965, amended
1972, 1992, 1993, 1995, 2011.