10 CSR 20-8.500
Design Requirements for Agrichemical Facilities
PURPOSE: This rule specifies the minimum standards for the
design of agrichemical facilities. It does not address all aspects
of design, and the design engineer may refer to other appropriate
reference materials so long as these minimum standards set forth
in this rule are met.
PUBLISHER’S NOTE: The secretary of state has determined that the
publication of the entire text of the material which is incorporated
by reference as a portion of this rule would be unduly cumbersome
or expensive. This material as incorporated by reference in this
rule shall be maintained by the agency at its headquarters and
shall be made available to the public for inspection and copying
at no more than the actual cost of reproduction. This note applies
only to the reference material. The entire text of the rule is printed
here.
(1) Applicability. This rule applies to all agrichemical facilities
and to the construction of new secondary and operational
containment of agrichemicals at existing facilities. All facilities
to which this rule applies shall be designed as no-discharge
systems.
(2) Exceptions.
(A) The prohibition of storing bulk liquid fertilizer in a mobile container for more than thirty (30) days shall not apply to
barges and rail cars used solely for transporting liquid fertilizer from chemical production facilities to retail or wholesale
facilities.
(B) The prohibition of burying pipes used for transferring full
strength agrichemicals shall not apply to piping used solely for
the loading and unloading of liquid fertilizer from barges and
rail cars. These pipes shall be pressure tested on a yearly basis
to certify the integrity of the pipes. Records of the pressure
testing shall be kept on file at the facility and made available
to Missouri Department of Natural Resources (department)
personnel upon request.
(C) Liquid fertilizer storage tanks that were in use prior to
January 13, 1992, having a storage capacity greater than forty
thousand (40,000) gallons are exempt from the requirement of
installing a liner underneath the tank itself. Spill containment
diking is required around these tanks.
(3) Engineering Report. An engineering report is required for
all facilities required by 10 CSR 20-6.010 to submit an application for a construction permit.
(4) Primary Containment for Bulk Liquid Agrichemicals for
new construction. Containers and appurtenances used as the
primary containment in the storage and handling of bulk agrichemicals shall be constructed, installed, and maintained to
prevent a discharge and shall be of materials and construction
compatible with the specifications of the product stored with:
(A) Tank anchors or raised stands;
(B) For self-supporting tanks, the ability to handle all operating stresses, hydrostatic head, pressure buildup from pumps
and compressors, and any other mechanical stresses to which
the containers and appurtenances may be subject to in the
foreseeable course of operation;
(C) No external sight gauges used with bulk pesticide storage
containers;
(D) Lockable valves for bulk liquid fertilizer containers located between the sight gauge and the storage container;
(E) A lockable main discharge valve;
(F) All appurtenances protected against damage from operating personnel and moving vehicles and located within the
secondary containment or operational containment area;
(G) All storage structures for bulk liquid pesticides or bulk
liquid fertilizers located above ground; and
(H) Secure transfer hose connections.
(5) Secondary Containment for Bulk Liquid Agrichemicals for
new construction. Secondary containment for nonmobile bulk
liquid pesticides and nonmobile bulk liquid fertilizers shall be
designed to contain any spilled product to prevent a discharge
with—
(A) Containment structures sized according to the
Environmental Protection Agency’s Code of Federal Regulations,
40 CFR 165.85, published July 1, 2014. This document shall
hereby be incorporated by reference without any later amendments or modifications. To obtain a copy, contact the U.S.
Government Printing Office at 732 North Capitol Street NW,
Washington, DC, 20401, toll free at (866) 512-1800 or by visiting
https://bookstore.gpo.gov;
(B) No discharge outlet or gravity drain through the wall or
floor of the containment structure;
(C) The walls and floors constructed of material that is compatible with the specifications of the product being stored;
resistant to penetration by moisture and agrichemicals; and
designed to support the gravity load of the storage containers
and any hydrostatic loads that would result from a massive spill
within the containment structure;
(D) Expansion joints spaced to prevent cracks from forming;
sealed with a material resistant to agrichemicals; and with
water stops installed between the containment walls and floor;
(E) A collection sump, if needed, shall not be more than two
feet (2') deep or larger than twenty (20) cubic feet; constructed
of materials that resist penetration by moisture and agrichemicals; with a sealed connection point between the containment
area floor; and at a low point in the containment area to allow
for removal of accumulated liquids;
(F) No piping installed through the walls or floor except for
through common, interconnecting containment walls and all
piping entering and leaving the secondary containment structure shall go up and over the containment walls;
(G) No buried transfer piping;
(H) Separation of bulk liquid pesticides and bulk liquid
fertilizers with a common wall and with no interconnecting
piping; and
(I) All tanks for storage of rinsate or precipitation collected in
the secondary or operational containment area located within
a secondary containment structure.
(J) Earthen structures used for secondary containment shall
be designed as follows:
1. Be constructed with a compacted soil liner or synthetic
liner with a permeability rate of 1 × 10-7 cm/sec. or less.
2. Be protected against erosion with side slopes no steeper
than three to one (3:1) and with a top width no less than two
and one-half feet (2 1/2').
(6) Nonmobile bulk dry fertilizer storage shall be designed to—
(A) Be stored inside a sound structure to prevent contact with
precipitation with all surface water runoff diverted away from
the storage structure;
(B) Allow for all unloading, loading, mixing, and handling of
dry bulk fertilizers to be done on an operational containment
area as required in section (9) of this rule;
(C) Have an adequately sized operational containment area
to hold the volume of pesticides used and impregnation equipment as required in section (9) of this rule;
(D) Allow for daily cleanup of the dry fertilizer loading, unloading, mixing, and handling areas;
(E) Prevent the downward movement of fertilizer materials
and moisture through the floor with expansion joints spaced
to prevent cracks from forming and sealed with a material
resistant to agrichemicals; and
(F) Have a mixing and loading pad constructed under any
exterior transfer area of a conveyance system.
(7) Nonmobile bulk dry pesticide storage shall be designed to—
(A) Be stored inside a sound structure to prevent contact with
precipitation and with all surface water runoff diverted away
from the storage structure;
(B) Allow for all loading, mixing, and handling of bulk dry
pesticides to be done on an operational containment area;
(C) Allow for daily cleanup of the bulk dry pesticide loading,
unloading, mixing, and handling areas;
(D) Prevent the downward movement of pesticides and moisture through the floor with expansion joints spaced to prevent
cracks from forming and sealed with a material resistant to
agrichemicals; and
(E) Have a mixing and loading pad under any exterior transfer area of a conveyance system.
(8) Operational containment for bulk liquid pesticides and bulk
liquid fertilizers for new construction shall be designed to:
(A) Divert runoff away from the operational containment
area;
(B) Contain any spilled product and any collected precipitation that comes in contact with spillage for the amount of time
needed for proper cleanup and recovery;
(C) Have a minimum volume in accordance with the
Environmental Protection Agency’s Code of Federal Regulations,
40 CFR 165.85, published July 1, 2014. This document shall
hereby be incorporated by reference without any later amendments or modifications. To obtain a copy, contact the U.S.
Government Printing Office at 732 North Capitol Street NW,
Washington, DC, 20401, toll free at (866)512-1800 or by visiting
https://bookstore.gpo.gov;
(D) Have a sediment trap and sump, if needed, not more than
two feet (2') deep or larger than 20 cubic feet and constructed
of materials that resist penetration by moisture and agrichemicals with a sealed connection point between the operational
containment area floor and the sump to prevent leakage of
liquids from the containment area;
(E) Extend beneath any pump, appurtenance, or plumbing
connection not located within the secondary containment area
and that is used to transfer liquid fertilizer or pesticide; and
(F) Allow for bulk repackaging containment of agrichemicals.
(9) Operational Containment Area for bulk dry pesticides and
bulk dry fertilizers for new construction shall be sized to—
(A) Divert runoff away from the operational containment
area;
(B) Contain any spillage of dry materials that occurs from
loading, unloading, or hauling; from spreading equipment;
and from mixing and blending equipment. Operational containment areas must also contain precipitation that comes in
contact with spillage for the amount of time needed for proper
cleanup and recovery;
(C) Individual catchment basins or portable pans/containers
may be used to satisfy the requirement for operational containment. The individual basins or portable containers shall be
placed to catch or recover spillage and leakage from transfer
connections and conveyors; and
(D) For unloading dry pesticides and dry fertilizers from rail
cars, a catchment basin or concrete pad that can effectively
contain the dry fertilizer or pesticide shall be used.
(10) Connection to Water Supplies. An air gap separation or
reduced pressure principle backflow prevention assembly shall
be installed in the water supply line that serves an agrichemical facility. The air gap or backflow prevention assembly shall
be constructed, installed, and inspected in accordance with 10
CSR 60-11.010 Prevention of Backflow.
(11) Protection from Flooding. All agrichemical facilities shall
be located so that the agrichemicals being stored are protected
from a one hundred- (100-) year flood event.
(12) Operation and Management of Agrichemical Facilities.
Field application of rinsate and collected precipitation is acceptable and recommended.
AUTHORITY: sections 644.026 and 644.036, RSMo 2016.* Original
rule filed July 15, 1991, effective Jan. 13, 1992. Amended: Filed Aug.
1, 2016, effective April 30, 2017. Amended: Filed June 15, 2018, effective Feb. 28, 2019.
*Original authority: 644.026, RSMo 1972, amended 1973, 1987, 1993, 1995, 2000, 2012,
2014 and 644.036, RSMo 1972, amended 1973, 2000, 2002, 2006, 2009, 2011.