10 CSR 20-9.010
Wastewater Treatment Systems Operation Scope Monitoring
PURPOSE: This regulation sets forth the
minimum requirements for laboratory testing
to ensure adequate wastewater treatment systems operation.
(1) Definitions. Definitions as set forth in the
Missouri Clean Water Law and 10 CSR 202.010 apply to the terms to be used in this
rule, unless the context clearly requires otherwise.
(2) Operational laboratory tests and related
monitoring for wastewater treatment systems
control are a supplement to the Missouri
State Operating Permit (MSOP) requirements. These operational monitoring reports
shall be submitted to the department along
with the MSOP discharge monitoring reports.
(3) The department may modify monitoring
frequency required in this rule based upon the
department’s judgement of monitoring needs
for process control at a specified facility.
(4) These requirements for laboratory tests
shall apply to all wastewater treatment systems owned or operated by or for municipalities, public sewer districts, or other local
government entities, private sewer companies
regulated by the Public Service Commission,
and the state agencies or any subdivision of
them, with a population equivalent, as
defined in 10 CSR 20-9.020, greater than two
hundred (200). All other systems are exempt.
(5) Minimum monitoring requirements to
ensure adequate wastewater treatment systems in-plant operational control are as follows:
(A) Lagoons
1. Discharging - Two (2)/Week Frequency.
Precipitation
Flow
Influent or Effluent
pH
Primary Cell
D.O.
Primary Cell
2. Non-Discharging – Two (2)/Month
Frequency.
Precipitation
Flow
Influent or Effluent
pH
Primary Cell
D.O.
Primary Cell
(B) Mechanical Plants.
1. All types—daily (Monday – Friday)
frequency.
Precipitation
Flow
Influent or Effluent
pH
Influent
Temperature Aeration basin
2. Additional laboratory test requirements for wastewater activated sludge processes and modifications:
Influent
Mixed Liquor
TSS
1/week
1/week
SettleDaily (Monday – Friday)
ability
(sample contact and
reaeration basins for
contact stabilization)
D.O.
Daily (Monday – Friday)
(sample contact and
reaeration basins for
contact stabilization)
Temperature
Daily (Monday – Friday)
(sample contact and
reaeration basins for
contact stabilization)
3. Additional tests for facilities having
digesters:
Anaerobic
Aerobic
pH
Daily
—
(Monday – Friday)
Temperature
Daily
—
(Monday – Friday)
D.O.
—
Daily
(Monday –
Friday)
(C) Recirculating filter media beds:
Pressure
2/year
by
measuring
squirt height in each zone
at the orifice furthest
from the pump. Use each
pump independently during the monitoring to
ensure each pump is
functioning.
(D) Facilities which chlorinate for disinfection shall perform total chlorine residual
analyses of the effluent on a daily (Monday –
Friday) basis during those periods when chlorination facilities are in use.
(E) Facilities employing disinfection technology other than chlorine shall have disinfection process control testing parameters and
frequency determined by the department on a
case-by-case basis.
(6) Laboratory procedures shall be performed
in accordance with 10 CSR 20-7.015.
(7) A copy of all reports required by this rule
shall be retained by the facility for a minimum of three (3) years.
AUTHORITY: section 644.026, RSMo 2016.*
Original rule filed July 15, 1976, effective
July 1, 1977. Amended: Filed Nov. 1, 1983,
effective July 1, 1984. Amended: Filed July
29, 1994, effective March 30, 1995. Amended: Filed Nov. 3, 1997, effective July 30,
1998. Amended: Filed June 13, 2018, effective Feb. 28, 2019.
*Original authority: 644.026, RSMo 1972, amended
1973, 1987, 1993, 1995, 2000, 2012, 2014.