19 CSR 20-10.050
Personnel Monitoring and Radiation Surveys
PURPOSE: This rule lists requirements for
personnel monitoring and radiation surveys.
Conditions under which routine monitoring of
individuals occupationally exposed to radiation shall not be required are also listed.
(1) The user shall provide for radiation surveys and monitoring sufficient to assure compliance with other rules of this chapter. The
radiation survey and monitoring shall be performed by, or under the direction of, a qualified expert using suitable instruments and
methods for measuring radiation.
(2) Until an actual radiation survey can be
performed, a written statement made by a
qualified expert based on his/her analysis of
the situation shall be acceptable as evidence
of the absence of radiation hazard in a given
area.
(3) Personnel monitoring shall be required
for each individual for whom there is any reasonable possibility of receiving a weekly dose
of all radiation exceeding fifty (50) millirems,
taking into consideration the use of protective
gloves, aprons or other radiation-limiting
devices.
(4) Routine monitoring of individuals occupationally exposed to radiation from radiation
machines shall not be required if—
(A) A qualified expert has specified the
operating conditions under which there is no
reasonable chance that any individual will be
subjected to a dose of either more than twenty-five (25) millirems in any seven (7) consecutive days or more than three hundred
twenty-five (325) millirems in any thirteen
(13) consecutive weeks;
(B) The operating conditions in subsection
(4)(A) of this rule are made known to all individuals who may be occupationally exposed
to the radiation; and
(C) The installation continues to operate
only under the specified conditions.
(5) Radiation surveys of sealed sources and
sealed storage areas shall be made at least
semiannually to insure the integrity of the
containment. The survey shall be capable of
detecting the presence of 0.005 microcurie of
removable contamination. If the survey
reveals the presence of 0.005 microcurie or
more of removable contamination, the user
shall immediately withdraw the sealed source
from use and shall cause it to be decontaminated and repaired, or disposed of, in accordance with procedures established by a qualified expert.
AUTHORITY: section 192.420, RSMo 1986.*
This rule was previously filed as 13 CSR 5090.050. Original rule filed Nov. 9, 1964,
effective Dec. 9, 1964.
*Original authority: 194.420, RSMo 1963.