10 CSR 50-2.065
Operations
PURPOSE: This rule provides for procedures
or requirements for activities as part of oil
and gas production operations. General
operations include hydrocarbon storage,
metering of produced gas, and spill response.
(1) Tank identification. All oil tanks, tank
batteries, tanks used for produced water collection or disposal, and tanks used for oilsediment treatment or storage shall be identified by a sign posted on, or not more than
fifty feet (50’) from, the tank or tank battery.
Within ninety (90) days of any transfer, the
transferee shall change the tank battery identification sign to include the new operator
information. The sign shall—
(A) Identify name, license number, and
contact information of the operator;
(B) Identify name of the lease or unit being
served by the tank;
(C) Identify location of the tank, including
section, township, range, and county;
(D) Identify contents of the tank;
(E) Be of durable construction; and
(F) Be large enough to be legible under
normal conditions at a distance of fifty feet
(50').
(2) Spill Notification. Each operator, immediately upon discovery or knowledge of any
spill or release, will take immediate action in
accordance with the Spill Bill, section
260.500 to 260.550, RSMo, and the implementing regulations in 10 CSR 24. This does
not alter responsible parties’ obligations
under any other applicable law.
AUTHORITY: section 259.060 and 259.070,
RSMo 2016.* Original rule filed Sept. 15,
2015, effective March 30, 2016. Amended:
Filed June 27, 2018, effective Feb. 28, 2019.
*Original authority: 259.060, RSMo 1965, amended 1972
and 259.070, RSMo 1965, amended 1972, 1983, 1987,
1993, 1995, 2012, 2015.