20 CSR 2220-2.950
Automated Filling Systems
PURPOSE: This rule establishes standards for automated filling
systems.
(1) Definitions. The following definitions shall be applicable for
purposes of this rule:
(A) “Automated filling system”—An automated system used
by a pharmacy to assist in filling a prescription drug order by
selecting, labeling, filling, or sealing medication for dispensing.
An “automated filling system” shall not include automated
devices used solely to count medication, vacuum tube drug
delivery systems governed by 20 CSR 2220-2.800, or automated
dispensing and storage systems governed by 20 CSR 22202.900 used to dispense medication directly to a patient or to an
authorized health care practitioner for immediate distribution
or administration to the patient;
(B) “Electronic
verification
system”—An
electronic
verification, bar code verification, weight verification, radio
frequency identification (RFID), or similar electronic process or
system that accurately verifies medication has been properly
dispensed and labeled by, or loaded into, an automated filling
system;
(C) “Manufacturer unit of use package”—A drug dispensed
in the manufacturer’s original and sealed packaging, or in
the original and sealed packaging of a repackager, without
additional manipulation or preparation by the pharmacy,
except for application of the pharmacy label;
(D) “Repackager”—A repackager registered with the United
States Food and Drug Administration; and
(E) “Repacked”—Any drug that has been removed from
the original packaging of the manufacturer or a repackager’s
packaging and is placed in a container for use in an automated
filling system.
(2) Medication Stocking. Automated filling systems (hereinafter
“system”) may be stocked or loaded by a pharmacist or by an
intern pharmacist or pharmacy technician under the direct
supervision of a pharmacist. Pharmacy repacked medication,
cartridges, or containers shall comply with 20 CSR 2220-2.130.
(3) Verification. Except as provided herein, a licensed pharmacist
shall inspect and verify the accuracy of the final contents of
any medication filled or packaged by an automated filling
system, and any label affixed thereto, prior to dispensing, as
required by 20 CSR 2220-2.010(1)(B).
(4) The pharmacist verification requirements of section (3) shall
be deemed satisfied if—
(A) The pharmacy establishes and follows a policy and
procedure manual that complies with section (5) of this rule;
(B) The filling process is fully automated from the time
the filling process is initiated until a completed, labeled,
and sealed prescription is produced by the automated filling
system that is ready for dispensing to the patient. No manual
intervention with the medication or prescription may occur
after the medication is loaded into the automated filling
system. For purposes of this section, manual intervention shall
not include preparing a finished prescription for mailing,
delivery, or storage;
(C) A pharmacist verifies the accuracy of the prescription
information used by or entered into the automatic filling
system for a specific patient prior to initiation of the automatic
fill process. The name, initials, or identification code(s) of the
verifying pharmacist shall be recorded in the pharmacy’s
records and maintained for five (5) years after dispensing;
(D) A pharmacist verifies the correct medication, repacked
container, or manufacturer unit of use package was properly
stocked, filled, and loaded in the automated filling system
prior to initiating the fill process. Alternatively, an electronic
verification system may be used for verification of manufacturer
unit of use packages or repacked medication previously
AND INSURANCE
verified by a pharmacist;
(E) The medication to be dispensed is filled, labeled, and
sealed in the prescription container by the automated filling
system or dispensed by the system in a manufacturer’s unit of
use package or a repacked pharmacy container;
(F) An electronic verification system is used to verify the
proper prescription label has been affixed to the correct
medication, repackaged container, or manufacturer unit of use
package for the correct patient; and
(G) Daily random quality testing is conducted by a pharmacist
on a sample size of prescriptions filled by the automated filling
system. The required sample size shall not be less than two
percent (2%) of the prescriptions filled by the automated system
on the date tested or two percent (2%) of the prescriptions filled
by the automated system on the last day of system operation,
as designated in writing by the pharmacist-in-charge. Proof of
compliance with this subsection and random quality testing
date(s) and results shall be documented and maintained in the
pharmacy’s records.
(5) Policies and Procedures. Pharmacies verifying prescriptions
pursuant to section (4) of this rule shall establish and follow
written policies and procedures to ensure the proper, safe, and
secure functioning of the system. Policies and procedures shall
be reviewed annually by the pharmacist-in-charge and shall be
maintained in the pharmacy’s records for a minimum of two
(2) years. The required annual review shall be documented in
the pharmacy’s records and made available upon request. At
a minimum, the pharmacy shall establish and follow policies
and procedures for—
(A) Maintaining the automated filling system and any
accompanying electronic verification system in good working
order;
(B) Ensuring accurate filling, loading, and stocking of the
system;
(C) Ensuring sanitary operations of the system and preventing
cross-contamination of cells, cartridges, containers, cassettes,
or packages;
(D) Reporting, investigating, and addressing filling errors
and system malfunctions;
(E) Testing the accuracy of the automated filling system
and any accompanying electronic verification system. At
a minimum, the automated filling system and electronic
verification system shall be tested before the first use of the
system or restarting the system and upon any modification to
the automated filling system or electronic verification system
that changes or alters the filling or electronic verification
process;
(F) Training persons authorized to access, stock, restock,
or load the automated filling system in equipment use and
operations;
(G) Tracking and documenting prescription errors related
to the automated filling system that are not corrected prior
to dispensing to the patient. Such documentation shall be
maintained for two (2) years and produced to the board upon
request;
(H) Conducting routine and preventive maintenance and, if
applicable, calibration;
(I) Removing expired, adulterated, misbranded, or recalled
drugs;
(J) Preventing unauthorized access to the system, including,
assigning, discontinuing, or changing security access;
(K) Identifying and recording persons responsible for
stocking, loading, and filling the system;
(L) Ensuring compliance with state and federal law, including,
all applicable labeling, storage, and security requirements; and
(M) Maintaining an ongoing quality assurance program that
monitors performance of the automatic fill system and any
electronic verification system to ensure proper and accurate
functioning.
(6) Recordkeeping. Except as otherwise provided herein, records
required by this rule shall be maintained in the pharmacy’s
records electronically or in writing for a minimum of two (2)
years. When the verification requirements of subsection (4)(D)
of this rule are completed by a pharmacist, the name, initials,
or identification code(s) of the verifying pharmacist shall be
recorded in the pharmacy’s records and maintained for five
(5) years after dispensing. Records shall be made available for
inspection and produced to the board or the board’s authorized
designee upon request.
AUTHORITY: sections 338.250 and 338.280, RSMo 2000, and
sections 338.140 and 338.210.4, RSMo Supp. 2013.* Original rule
filed July 1, 2013, effective Jan. 30, 2014.
*Original authority: 338.140, RSMo 1939, amended 1989, 1997, 2011; 338.210, RSMo
1951, amended 2001, 2011; 338.250, RSMo 1951, amended 1990, 1998; and 338.280,
RSMo 1951, amended 1971, 1981.