10 CSR 60-2.015
Definitions
PURPOSE: This rule defines terms used in 10
CSR 60.
PUBLISHER’S NOTE: The secretary of state
has determined that the publication of the
entire text of the material which is incorporated by reference as a portion of this rule
would be unduly cumbersome or expensive.
This material as incorporated by reference in
this rule shall be maintained by the agency at
its headquarters and shall be made available
to the public for inspection and copying at no
more than the actual cost of reproduction.
This note applies only to the reference material. The entire text of the rule is printed
here.
(1) The terms used in 10 CSR 60 shall have
the meanings set forth in the Missouri Safe
Drinking Water Act, the federal Safe
Drinking Water Act and regulations, or this
rule, unless the context of the term clearly
requires otherwise. In the event of any conflict or inconsistency, the more stringent definition shall apply.
(2) Definitions.
(A) Terms beginning with the letter A.
1. Action level. The concentration of
lead or copper in water which determines, in
some cases, the treatment requirements, system modifications, public education, or other
requirements as specified by the department
that a water system is required to complete.
2. Air-gap separation. A backflow prevention assembly consisting of a physical separation between the free-flowing discharge
end of a public water system pipeline and an
open or nonpressurized receiving vessel. An
approved air-gap separation shall be at least
twice the diameter of the system pipe measured vertically above the overflow rim of the
vessel. In no case shall the distance be less
than one inch (1").
3. Alpha particle. A particle identical
with a helium nucleus, emitted from the
nucleus of a radioactive element.
4. Applicant. The legal name of the public water system for purposes of 10 CSR-60.
5. Auxiliary intake. Any piping, connection, or device whereby water may be secured
from a source other than the primary source.
6. Auxiliary water system. Any supply
or source of water other than the approved
public water system.
(B) Terms beginning with the letter B.
1. Backflow. The undesirable reversal of
flow of water or mixtures of water and other
liquids, gases, or other substances into the
public water system from any source(s).
2. Backflow hazard. Any facility which,
because of the nature and extent of activities
on the premises or the materials used in connection with the activities or stored on the
premises, would present an actual or potential
health hazard to customers of the public water
system or would threaten to degrade the water
quality of the public water system should
backflow occur.
A. Class I backflow hazard. A backflow hazard which presents an actual or
potential health hazard to customers of the
public water system should backflow occur.
A list of customer facilities, not all inclusive,
considered to be Class I backflow hazards is
included in 10 CSR 60-11.010.
B. Class II backflow hazard. A backflow hazard which would threaten to degrade
the water quality of the public water system
should backflow occur. A list of customer
facilities, not all inclusive, considered to be
Class II backflow hazards is included in 10
CSR 60-11.010.
3. Backflow prevention assembly. An
assembly designed to prevent the reverse flow
of water or other substances from a customer
facility back into the public water distribution
system. See also definitions of air-gap separation, double check valve, and reduced pressure principle backflow prevention assembly.
4. Backflow prevention assembly tester.
A person who utilizes recognized backflow
prevention assembly testing procedures to
determine whether or not an assembly is
functioning properly. Requirements for backflow prevention assembly tester certification
are in 10 CSR 60-11.
5. Bag filters. Pressure-driven separation devices that remove particulate matter
larger than one (1) micrometer using an engineered porous filtration media. They are typically constructed of a non-rigid, fabric filtration media housed in a pressure vessel in
which the direction of flow is from the inside
of the bag to the outside.
6. Bank filtration. Water treatment process that uses a well to recover surface water
that has naturally infiltrated into ground
water through a river bed or bank(s).
Infiltration is typically enhanced by the
hydraulic gradient imposed by a nearby
pumping water supply or other well(s).
7. Best available technology. The best
technology, treatment, or other means which
the department finds, after examination for
efficacy under field conditions and not solely
under laboratory conditions, are available
(taking cost into consideration). For the purpose of setting maximum contaminant levels
for synthetic organic chemicals, any best
available technology must be at least as effective as granular activated carbon.
8. Beta particle. A particle, identical
with an electron, emitted from the nucleus of
a radioactive element.
9. Breakpoint chlorination. The point at
which sufficient chlorine has been applied to
water to satisfy the chlorine demand which
should result in a total chlorine residual of at
least seventy-five percent (75%) free available chlorine.
(C) Terms beginning with the letter C.
1. Cartridge filters. Pressure-driven separation devices that remove particulate matter
larger than one (1) micrometer using an engineered porous filtration media. They are typically constructed as rigid or semi-rigid, selfsupporting filter elements housed in pressure
vessels in which flow is from the outside of
the cartridge to the inside.
2. Certificate. The certificate of competency issued by the department stating that a
person has met the requirements for the specified operator classification of the certification program under the provisions of 10 CSR
60-14.020.
3. Certificate of examination. A certificate issued to a person who passes a written
examination but does not meet the experience
requirements for the classification of examination taken.
4. Chief operator. The person designated by the owner of a public water system to
have direct, on-site responsibility for the
operation of a water treatment plant or water
distribution system, or both.
5. Chloramines. All amino or imino
groups in which the hydrogen has been
replaced totally or in part by chlorine.
6. Class I backflow hazard. See backflow hazard.
7. Class II backflow hazard. See backflow hazard.
8. Clean compliance history. For the purposes of 10 CSR 60-4.022, a record of no
E.coli Maximum Contaminant Level violations, no monitoring violations, and no coliform treatment technique trigger exceedances
or treatment technique violations for a minimum of the previous twelve (12) consecutive
months.
9. Coagulation. A process using coagulant chemicals and mixing by which colloidal
and suspended materials are destabilized and
agglomerated into flocs.
10. Combined chlorine residual. That
portion of the total chlorine residual which is
not free available chlorine.
11. Combined distribution system. The
interconnected distribution system consisting
of the distribution systems of wholesale systems and of the consecutive systems that
receive finished water.
12. Community water system. A public
water system which serves at least fifteen
(15) service connections and is operated on a
year-round basis or regularly serves at least
twenty-five (25) residents on a year-round
basis.
13. Compliance cycle. A nine- (9-) year
calendar year cycle during which public water
systems must monitor. Each compliance cycle
consists of three (3), three- (3-) year compliance periods. The first calendar year cycle
begins January 1, 1993 and ends December
31, 2001 and continues in nine- (9-) year
cycles thereafter.
14. Compliance period. A three- (3-)
year calendar year period within a compliance cycle. Each compliance cycle has three
(3), three- (3-) year compliance periods. The
first compliance period begins at the start of
a compliance cycle.
15. Confluent growth. A continuous
bacterial growth covering the entire filtration
area of a membrane filter, or a portion of the
area, in which bacterial colonies are not discrete.
16. Consecutive system. A public water
system that receives some or all of its finished
water from one (1) or more wholesale systems. Delivery may be through a direct connection or through the distribution system of
one (1) or more consecutive systems.
17. Consolidated formations. Earth
material which has been created by geological processes, cemented, or compacted into a
coherent or firm mass.
18. Containment. Protection of the public water system by installation of a department-approved backflow prevention assembly
or air-gap separation at the user connection
from the main service line(s).
19. Contaminant. Any physical, chemical, biological, or radiological substance or
matter in water including, but not limited to,
those substances for which maximum contaminant levels are established by the department.
20. Conventional filtration treatment. A
series of treatment processes including coagulation, flocculation, sedimentation, and filtration resulting in substantial particulate
removal.
A. Required treatment for ground
water systems under the direct influence of
surface water. One (1) stage of treatment
must be provided as follows: rapid mix, flocculation, and sedimentation followed by filtration. Disinfection also shall be provided.
Raw water quality characteristics may require
additional treatment.
B. Required treatment for surface
water systems. Two (2) stages of treatment
must be provided as follows: primary rapid
mix, flocculation, and sedimentation followed by secondary rapid mix, flocculation,
and sedimentation, operated in series, followed by filtration and disinfection contact
storage. Raw water quality characteristics
may require additional treatment.
21. Corrosion inhibitor. A substance
capable of reducing the corrosivity of water
toward metal plumbing materials, especially
lead and copper, by forming a protective film
on the interior surface of those materials.
22. Cross-connection. Any actual or
potential connection or structural arrangement between a public water system and any
other source or system through which it is
possible to introduce into any part of the public water system any used water, industrial
fluid, gas, or substance other than the intended potable water with which the system is
supplied. By-pass arrangements, jumper connections, removable sections, swivel or
change-over devices, and other temporary or
permanent devices through which or because
of which, backflow can or may occur are
considered to be cross-connections.
23. CT. The product of the residual disinfectant concentration (C) in milligrams per
Liter (mg/L) determined before or at the first
customer and the corresponding disinfectant
contact time (T) in minutes (that is, C multiplied by T (C Ă— T)). (See also residual disinfectant concentration and disinfectant contact time.)
24. Customer. Any person who receives
water from a public water system.
25. Customer service line. The pipeline
from the public water system to the first tap,
fixture, receptacle, or other point of customer
water use or to the first auxiliary water system or pipeline branch in a building.
26. Customer water system. All piping,
fixtures, and appurtenances, including auxiliary water systems, used by a customer to
convey water on his/her premises.
(D) Terms beginning with the letter D.
1. Department. The Missouri Department
of Natural Resources.
2. Department of Health. The Missouri
Department of Health and Senior Services.
3. Director. The director of the Missouri
Department of Natural Resources.
4. Disinfectant. Includes, but is not limited to, chlorine, chlorine dioxide, chloramines, and ozone added to water in any
part of the treatment or distribution process,
that is intended to kill or inactivate
pathogenic microorganisms.
5. Disinfectant contact time. The “T” in
the equation CT. The time in minutes that it
takes for water to move from the point of disinfectant application or the previous point of
disinfectant residual measurement to a point
before or at the point where residual disinfectant concentration (C) is measured as
determined by a department-approved study
as outlined in the Missouri Guidance Manual
for
Surface
Water
System
Treatment
Requirements, 1992.
6. Disinfection. A process which inactivates pathogenic organisms in water by chemical oxidants or equivalent agents.
7. Domestic or other nondistribution
system plumbing problem. A coliform contamination problem in a public water system
with more than one (1) service connection
that is limited to the specific service connection from which the coliform-positive sample
was taken.
8. Dose equivalent. The product of the
absorbed dose from ionizing radiation and
factors that account for difference in biological effectiveness due to the type of radiation
and its distribution in the body as specified by
the International Commission of Radiological
Units and Measurements (ICRU).
9. Double check valve assembly. A
backflow prevention assembly composed of
two (2) single, independently acting, internally spring loaded, approved check valves
including tightly closing resilient-seated shutoff valves located at each end of the assembly
and fitted with properly located test cocks.
10. Dual sample set. A set of two (2)
samples collected at the same time and same
location, with one (1) sample analyzed for
total trihalomethanes (TTHM) and the other
sample analyzed for haloacetic acids 5
(HAA5). Dual sample sets are collected for
the purposes of conducting an initial distribution system evaluation (IDSE) and determining
compliance with the TTHM and HAA5 maximum contaminant levels (MCLs) under Stage
2 Disinfectants/Disinfection By-Products
requirements.
(E) Terms beginning with the letter E.
1. Effective corrosion inhibitor residual.
For the purpose of the lead and copper provisions of these rules, a concentration sufficient
to form a protective film on the interior walls
of a pipe.
2. Engineer. An individual registered as
a professional engineer in Missouri.
3. Enhanced coagulation. The addition
of sufficient coagulant for improved removal
of disinfection byproduct precursors by conventional filtration treatment.
4. Enhanced softening. The improved
removal of disinfection byproduct precursors
by precipitative softening.
(F) Terms beginning with the letter F.
1. Facility. A single tract or contiguous
tracts of land and any improvements on them,
upon which one (1) or more service connections are located, and which, except for easements and public right-of-way, are wholly
owned, leased, or otherwise subject to the
control of the customer.
2. Filter profile. A graphical representation of individual filter performance, based
on continuous turbidity measurements or
total particle counts versus time for an entire
filter run, from startup to backwash inclusively, that includes an assessment of filter
performance while another filter is being
backwashed.
3. Filtration. A process for removing
particulate matter from water by passage
through porous media.
4. Finished water. Water that is introduced into the distribution system of a public
water system and is intended for distribution
and consumption without further treatment,
except treatment necessary to maintain water
quality in the distribution system (for example, booster disinfection, addition of corrosion control chemicals).
5. Finished water storage facility. A
tank, reservoir, or other man-made facility
used to store potable water that will undergo
no further treatment except residual disinfection.
6. First draw sample. A one (1) liter
sample of tap water, collected in accordance
with the lead and copper provisions of these
rules only, that has been standing in plumbing pipes at least six (6) hours and is collected without flushing the tap.
7. Flocculation. A process to enhance
the collection of smaller floc particles into
larger, more easily settleable particles
through gentle stirring by hydraulic or
mechanical means.
8. Flowing stream. A course of running
water flowing in a definite channel.
(G) Terms beginning with the letter G.
1. GAC10. Granular activated carbon
filter beds with an empty-bed contact time of
ten (10) minutes based on average daily flow
and a carbon reactivation frequency of every
one hundred eighty (180) days, except that
the reactivation frequency for GAC10 used as
a best available technology for compliance
with Stage 2 Disinfectants/Disinfection ByProducts is one hundred twenty (120) days.
2. GAC20. Granular activated carbon
filter beds with an empty-bed contact time of
twenty (20) minutes based on average daily
flow and a carbon reactivation frequency of
every two hundred forty (240) days.
3. Gross alpha particle activity. The
total radioactivity due to alpha particle emission as inferred from measurements on a dry
sample.
4. Gross beta particle activity. The total
radioactivity due to beta particle emission as
inferred from measurements on a dry sample.
5. Ground water under the direct influence of surface water (GWUDISW). Any
water beneath the surface of the ground with
either of the following:
A. Significant and relatively rapid
shifts in water characteristics such as turbidity, temperature, conductivity, or pH which
closely correlate to climatological or surface
water conditions. Direct influence must be
determined for individual sources in accordance with criteria established by the department. The department’s determination of
direct influence may be used on site-specific
measurements of water quality or documentation of well construction characteristics, or
both, and geology with field evaluation; or
B. Significant occurrence of insects or
other macroorganisms, algae, or large-diameter pathogens such as Giardia lamblia or
Cryptosporidium.
(H) Terms beginning with the letter H.
1. Haloacetic acids (five) (HAA5). The
sum of the concentrations in milligrams per
liter of the haloacetic acid compounds
(monochloroacetic acid, dichloroacetic acid,
trichloroacetic acid, monobromoacetic acid,
and dibromoacetic acid), rounded to two (2)
significant figures after addition.
(I) Terms beginning with the letter I.
1. Initial Compliance Period. That period beginning January 1, 1993, for existing
sources. For new water supply sources, the
first full three- (3-) year compliance period
which begins no more than eighteen (18)
months after the source is placed in service.
2. Iron removal. The removal of iron
and manganese from a ground water source
with the treated water being exposed to aeration and chemical oxidation, pH adjustment,
sedimentation and filtration.
(J) Terms beginning with the letter J.
(Reserved)
(K) Terms beginning with the letter K.
(Reserved)
(L) Terms beginning with the letter L.
1. Lake/reservoir. A natural or manmade basin or hollow on the earth’s surface
in which water collects or is stored that may
or may not have a current or single direction
of flow.
2. Lead service line. A service line
made of lead which connects the water main
to the building inlet and any lead pigtail,
gooseneck, or other fitting which is connected to that lead line.
3. Legionella. A genus of bacteria some
species of which have caused a type of pneumonia called Legionnaires disease.
4. Level 1 assessment is an evaluation to
identify the possible presence of sanitary
defects, defects in distribution system coliform monitoring practices, and (when possible) the likely reason that the system triggered the assessment. It is conducted by the
system operator or owner. Minimum elements include review and identification of
atypical events that could affect distributed
water quality or indicate that distributed
water quality was impaired; changes in distribution system maintenance and operation that
could affect distributed water quality (including water storage); source and treatment considerations that bear on distributed water
quality, where appropriate (e.g., whether a
ground water system is disinfected); existing
water quality monitoring data; and inadequacies in sample sites, sampling protocol, and
sample processing. The system must conduct
the assessment consistent with any department directives that tailor specific assessment
elements with respect to the size and type of
the system and the size, type, and characteristics of the distribution system.
5. Level 2 assessment is an evaluation to
identify the possible presence of sanitary
defects, defects in distribution system coliform monitoring practices, and (when possible) the likely reason that the system triggered the assessment. A Level 2 assessment
provides a more detailed examination of the
system (including the system’s monitoring
and operational practices) than does a Level 1
assessment through the use of more comprehensive investigation and review of available
information, additional internal and external
resources, and other relevant practices. It is
conducted by an individual approved by the
department, which may include the system
operator. Minimum elements include review
and identification of atypical events that
could affect distributed water quality or indicate that distributed water quality was
impaired; changes in distribution system
maintenance and operation that could affect
distributed water quality (including water
storage); source and treatment considerations
that bear on distributed water quality, where
appropriate (e.g., whether a ground water
system is disinfected); existing water quality
monitoring data; and inadequacies in sample
sites, sampling protocol, and sample processing. The system must conduct the assessment
consistent with any department directives that
tailor specific assessment elements with
respect to the size and type of the system and
the size, type, and characteristics of the distribution system. The system must comply
with any expedited actions or additional
actions required by the department in the case
of an E. coli MCL violation.
6. Lime softening. The application of
lime to reduce the concentrations of calcium
and magnesium and, to a lesser extent, iron,
manganese, or radionuclides from source
water.
7. Locational running annual average
(LRAA). The average of sample analytical
results for samples taken at a particular monitoring location during the previous four (4)
calendar quarters.
(M) Terms beginning with the letter M.
1. Man-made beta particle and photon
emitters. All radionuclides emitting beta particles, photons, or both, except the daughter
products of thorium 232, uranium 235, and
uranium
238,
listed
in
the
EPA
Implementation Guidance for Radionuclides,
Appendix J.
2. Maximum contaminant level (MCL).
The maximum permissible level, as established in 10 CSR 60-4, of a contaminant in
any water which is delivered to any user of a
public water system.
3. Maximum contaminant level goal
(MCLG). A level of a contaminant in drinking water at which no known or anticipated
adverse effect on the health of persons would
occur and which allows an adequate margin
of safety. MCLGs are nonenforceable health
goals.
4. Maximum residual disinfectant level
(MRDL). A level of a disinfectant that may
not be exceeded at the consumer’s tap without an unacceptable possibility of adverse
health effects.
5. Maximum residual disinfectant level
goal (MRDLG). The maximum level of a disinfectant added for water treatment at which
no known or anticipated adverse effect on the
health of persons would occur, and which
allows an adequate margin of safety.
MRDLGs are nonenforceable health goals
and do not reflect the benefit of the addition
of the chemical for control of waterborne
microbial contaminants.
6. Maximum total trihalomethane potential (MTTHMP). The maximum concentration of total trihalomethanes produced in a
given water containing a disinfectant residual
after seven (7) days at a temperature of twenty-five degrees Celsius (25 °C) or above.
7. Membrane filtration. Pressure or vacuum driven separation process in which particulate matter larger than one (1) micrometer is rejected by an engineered barrier, primarily through a size-exclusion mechanism,
and which has a measurable removal efficiency of a target organism that can be verified
through the application of a direct integrity
test. This definition includes the common
membrane technologies of microfiltration,
ultrafiltration, nanofiltration, and reverse
osmosis.
8. Missouri Guidance Manual for Surface
Water System Treatment Requirements, 1992.
This document is published by the Missouri
Department of Natural Resources, PO Box
176, Jefferson City, MO 65102-0176, dated
1992, which is hereby incorporated by reference without any later amendments or modifications.
9. Missouri Safe Drinking Water Law.
The Revised Statutes of Missouri, sections
640.100 through 640.140.
(N) Terms beginning with the letter N.
1. Near the first service connection. At
one (1) of the twenty percent (20%) of all service connections in the entire system that are
nearest the water supply treatment facility, as
measured by water transport time within the
distribution system.
2. Nontransient noncommunity water
system. A public water system that is not a
community water system and that regularly
serves at least twenty-five (25) of the same
persons over six (6) months per year.
(O) Terms beginning with the letter O.
1. On-site inspection. An on-site review
of the water source, facilities, equipment,
operation, and maintenance of a public water
system for the purpose of evaluating the adequacy of that source, facilities, equipment,
operation, and maintenance for producing
and distributing safe drinking water.
2. Operator. Any individual who operates or determines the methods of operating a
water system, either directly or by order.
3. Optimal corrosion control treatment.
For the purpose of the lead and copper provisions of these rules only, means the corrosion
control treatment that minimizes the lead and
copper concentrations at users’ taps while
insuring that the treatment does not cause the
water system to violate any other drinking
water regulations.
(P) Terms beginning with the letter P.
1. Person. Any individual, partnership,
co-partnership, firm, company, public or private corporation, association, homeowners’
association, joint stock company, trust,
estate, political subdivision or any agency,
board, department, or bureau of the state or
federal government, or any other legal entity
whatever, which is recognized by law as the
subject of rights and duties.
2. Picocurie (pCi). The quantity of
radioactive material producing 2.22 nuclear
transformations per minute.
3. Plant intake. The works or structures
at the head of a conduit through which water
is diverted from a source (for example, river
or lake) into the treatment plant.
4. Point of entry treatment device
(POE). A treatment device applied to the
drinking water entering a house or other
building for the purpose of reducing contaminants in the drinking water distributed
throughout the house or building.
5. Point of use treatment device (POU).
A treatment device applied to a single tap for
the purpose of reducing contaminants in the
drinking water at that tap.
6. Presedimentation. A preliminary
treatment process used to remove gravel,
sand, and other particulate material from the
source water through settling before the water
enters the primary clarification and filtration
processes in a treatment plant.
7. Primary public water system. A public water system which obtains its source of
water directly from a well, infiltration
gallery, lake, reservoir, river, spring, or
stream.
8. Public water system. A system for the
provision to the public of piped water for
human consumption, if the system has at least
fifteen (15) service connections or regularly
serves an average of at least twenty-five (25)
individuals daily at least sixty (60) days out of
the year. The system includes any collection,
treatment, storage, or distribution facilities
used in connection with the system. A public
water system is either a community water system or a noncommunity water system.
(Q) Terms beginning with the letter Q.
1. Quarterly. Unless otherwise specified
in 10 CSR 60, quarterly refers to the calendar quarters, January through March, April
through June, July through September, and
October through December.
(R) Terms beginning with the letter R.
1. Radioactivity. The spontaneous,
uncontrollable disintegration of the nucleus of
an atom with the emission of particles and
rays.
2. Rapid mix. The rapid dispersion of
chemicals throughout the water to be treated
by violent agitation.
3. Reduced pressure principle backflow
prevention assembly. A device containing two
(2) independently acting, internally spring
loaded, approved check valves, together with
a hydraulically operating, mechanically independent pressure differential relief valve
located between the check valves and below
the first check valve. The unit shall include
properly located test cocks and tightly closing, resilient-seated shut-off valves at each
end of the assembly.
4. Rem. The unit of dose equivalent
from ionizing radiation to the total body or
any internal organ or organ system. A millirem (mrem) is one one-thousandth (1/1000)
of a rem.
5. Repeat compliance period. Any subsequent compliance period after the initial
compliance period.
6. Residual disinfectant concentration.
The “C” in the equation CT. The concentration of disinfectant measured in milligrams
per liter (mg/L) in a representative sample of
water.
7. Rural. Shall not include any area in
any city or town which has a population in
excess of ten thousand (10,000) inhabitants
according to the latest reliable population
estimate for purposes of 10 CSR 60-13.010.
(S) Terms beginning with the letter S.
1. Sanitary defect is a defect that could
provide a pathway of entry for microbial contamination into the distribution system or that
is indicative of a failure or imminent failure
in a barrier that is already in place.
2. Sanitary survey. An on-site engineering inspection and review of a public water
system—its supply source(s), treatment of
supply source(s), treatment facilities, and distribution system(s), for the purpose of evaluating their adequacy, reliability, and safety for
producing and distributing drinking water.
3. Seasonal system is a non-community
water system that is not operated as a public
water system on a year-round basis and starts
up and shuts down at the beginning and end
of each operating season.
4. Secondary contaminant levels. Those
contaminant levels established by the department for contaminants which may affect the
taste, odor, color, staining, and scale-forming
tendencies of water.
5. Secondary public water system. A
public water system which obtains all its
water from an approved public water system(s), consists of a water distribution system, and resells the water or is a carrier
which conveys passengers in interstate commerce. Parts of a primary public water system
may be classified as being a secondary public
water system if they meet this definition and
are physically separated from those parts
served by the source for the primary public
water system.
6. Sedimentation. A process for removal
of solids before filtration by gravity separation.
7. Service connection. Any water line or
pipe connected to a water distribution main
or pipe for the purpose of conveying water to
a point of use.
8. Service line sample. A one (1) liter
sample of water, collected in accordance with
the lead and copper provisions of these rules
only, that has been standing for at least six (6)
hours in a service line.
9. Single family structure. For the purpose of the lead and copper provisions of
these rules only, a building constructed as a
single family residence that is currently used
as either a residence or a place of business.
10. Standard
Methods
for
the
Examination of Water and Wastewater, 18th
Edition. This refers to the document published
by the American Public Health Association,
American Water Works Association, and the
Water Environmental Federation in 1992
which is hereby incorporated by reference
without any later amendments or modifications. To obtain a copy, contact the American
Public Health Association at 1015 Fifteenth
Street NW, Washington DC, 20005.
11. Subdivision. Any land which is
divided, or proposed to be divided, into fifteen (15) or more lots or tracts, whether contiguous or not, for the purpose of sale, lease,
rental, or construction of permanent structures on lots or tracts as part of a common
plan; or where subdivided land is offered for
sale or lease, or where structures are constructed by a single developer or a group of
developers acting in concert and where the
lots or land or structures are contiguous or
known, designated, or advertised as a common unit or by a common name. The lots or
land tracts and structures shall be presumed,
without regard to the number of lots or
dwellings covered by each individual offering, as being offered for sale or lease as part
of a common plan.
12. Supplier of water. Any person who
owns, controls, or operates a public water
system.
13. Surface water. All water which is
open to the atmosphere and subject to surface
runoff; this includes all tributary streams and
drainage basins, natural lakes, and artificial
reservoirs above the point of the water supply
intake.
14. System with a single service connection. A system which supplies drinking
water to consumers via a single service line.
(T) Terms beginning with the letter T.
1. Too numerous to count (TNTC). The
total number of bacterial colonies exceeds
two hundred (200) on a forty-seven millimeter (47 mm) diameter membrane filter used
for coliform detection.
2. Total organic carbon (TOC). Total
organic carbon in milligrams per liter (mg/L)
measured using heat, oxygen, ultraviolet irradiation, chemical oxidants, or combinations
of these oxidants that convert organic carbon
to carbon dioxide, rounded to two (2) significant figures.
3. Total trihalomethanes (TTHM). The
sum of the concentration in mg/L of the trihalomethane compounds, trichloromethane
(chloroform), dibromochloromethane, bromodichloromethane, and tribromomethane
(bromoform), rounded to two (2) significant
figures.
4. Transient noncommunity water system. A public water system that is not a community water system, which has at least fifteen (15) service connections or regularly
serves an average of at least twenty-five (25)
individuals daily at least sixty (60) days out of
the year.
5. Treated water. Water which is handled or processed in any manner to change
the physical, chemical, biological, or radiological content and includes water exposed to
the atmosphere by aeration.
6. Trihalomethane (THM). One (1) of
the family of organic compounds, named as
derivatives of methane, where three (3) of the
four (4) hydrogen atoms in methane are each
substituted by a halogen atom in the molecular structure.
7. Two- (2-) stage lime softening. A process in which chemical addition and hardness
precipitation occur in each of two (2) distinct
unit clarification processes in series prior to
filtration.
(U) Terms beginning with the letter U.
1. Unconsolidated formations. Earth
material (sand, gravel, silt, clay) which is
uncemented and uncompacted and which has
been deposited by a natural process. This
material retains loose or relatively soft physical characteristics.
2. Uncovered finished water storage
facility. A tank, reservoir, or other facility
used to store water that will undergo no further treatment to reduce microbial pathogens
except residual disinfection and is directly
open to the atmosphere. (Note: uncovered
finished water storage facilities are prohibited
under 10 CSR 60-4.080(7).)
(V) Terms beginning with the letter V.
1. Virus. A virus of fecal origin which
is infectious to humans by waterborne transmission.
(W) Terms beginning with the letter W.
1. Water distribution main. A pipe within the water distribution system that delivers
finished drinking water from a water supply
source, treatment plant, or storage tank to a
service connection, hydrant, or to a customer
service line.
2. Water distribution system. All piping,
conduits, valves, hydrants, storage facilities,
pumps, and other appurtenances, excluding
service connections, which serve to deliver
water from a water treatment plant or water
supply source to the public.
3. Water system. All sources from
which water is derived for drinking or
domestic use by the public, also all structures, conduits, and appurtenances by means
of which water for use is treated, stored, or
delivered to consumers, except service connections from water distribution systems to
buildings and plumbing within or in connection with buildings served.
4. Water supply source. All sources of
water supply including wells, infiltration galleries, springs, reservoirs, lakes, streams, or
rivers from which water is derived for public
water systems, including the structures, conduits, pumps, and appurtenances used to
withdraw water from the source or to store or
transport water to the water treatment facility
or water distribution system.
5.Water treatment facility. A facility
which uses specific processes such as sedimentation, coagulation, filtration, disinfection, aeration, oxidation, ion exchange, fluoridation, or other processes which serve to
add components or to alter or remove contaminants from a water supply source.
6. Waterborne disease outbreak. The
significant occurrence of acute infectious illness associated with the ingestion of water as
declared by the Department of Health and
Senior Services.
7. Wholesale system. A public water
system that treats source water as necessary
to produce finished water and then delivers
some or all of that finished water to another
public water system. Delivery may be
through a direct connection or through the
distribution system of one (1) or more consecutive systems.
AUTHORITY: section 640.100, RSMo 2016.*
Original rule filed May 4, 1979, effective
Sept. 14, 1979. Amended: Filed April 14,
1981, effective Oct. 11, 1981. Amended: Filed
July 11, 1986, effective Jan. 1, 1987.
Amended: Filed June 2, 1988, effective Aug.
31, 1988. Amended: Filed Dec. 4, 1990,
effective July 8, 1991. Amended: Filed July
12, 1991, effective Feb. 6, 1992. Amended:
Filed March 31, 1992, effective Dec. 3, 1992.
Amended: Filed Aug. 4, 1992, effective May
6, 1993. Amended: Filed Dec. 14, 1992,
effective Aug. 9, 1993. Amended: Filed May
4, 1993, effective Jan. 13, 1994. Amended:
Filed Feb. 1, 1996, effective Oct. 30, 1996.
Amended: Filed Jan. 2, 1997, effective Dec.
29, 1997. Amended: Filed Dec. 15, 1999,
effective Sept. 1, 2000. Amended: Filed
March 17, 2003, effective Nov. 30, 2003.
Amended: Filed Feb. 27, 2009, effective Oct.
30, 2009. Amended: Filed Aug. 12, 2015,
effective March 30, 2016. Amended: Filed
April 13, 2018, effective Dec. 30, 2018.
*Original authority: 640.100, RSMo 1939, amended 1978,
1981, 1982, 1988, 1989, 1992, 1993, 1995, 1996, 1998,
1999, 2002, 2006, 2012, 2014.