2 CSR 90-21.050
Requirements for Pitless Scales
PURPOSE: This rule covers installation requirements for pitless
scales.
(1) This rule shall apply to the installation of vehicle, axle-load
and livestock scales of pitless full electronic or mechanical and
self-contained electronic or mechanical design being installed
in one (1) permanent location for more than one hundred
eighty (180) days.
(A) A pitless scale may be installed in a pit; however, all pit
requirements of 2 CSR 90-21.030 must be met.
(2) All scales represented as complying with this rule shall meet
all of the standards specified and all applicable specifications
and performance requirements of the current edition of
National Institute of Standards and Technology (NIST) Handbook
44, Specifications, Tolerances, and Other Technical Requirements
for Weighing and Measuring Devices.
(3) Whenever the provisions of this rule call for the use
of reinforced concrete, the concrete shall be of grade and
reinforced in the manner consistent with the guidelines
established by the American Concrete Institute.
(4) A suitable foundation must be provided for the scale to
rest on. This foundation should meet the following minimum
requirements:
(A) Adequate bearing area to match piers to existing soil
bearing capabilities stabilized at the desired grade (elevation)
to support at least three thousand (3000) pounds per square
foot in pier locations;
(B) The scale foundations installer shall be responsible for
determining whether or not soil characteristics meet the
requirements of subsections (4)(A) for a particular design, by
employing a penetrometer or plate-bearing test using proper
American Society of Testing and Materials (ASTM) guidelines.
If soil conditions do not meet those requirements, the installer
shall notify the owner; and the owner shall arrange for spread
footing design modifications to suit the existing soil conditions;
(C) The scale may be installed above the ground; however,
the installation should be such that surface water will drain
away from the scale area; and
(D) Access to critical scale parts must be provided to permit
proper inspection, servicing and cleaning.
(5) Piers.
(A) Piers shall be of reinforced concrete poured to the depth
of the local frost line but not less than three feet (3').
(B) All piers must be interlocked by a solid reinforced concrete
slab with a minimum thickness of six inches (6"). This slab may
be below the top of the piers to promote access and cleanout;
or by reinforced concrete sides with a minimum thickness of
twelve inches (12") and the same depth as the piers in which
case the horizontal area between the piers will be of concrete
with a minimum thickness of three inches (3"), not necessarily
tied to the piers or in the same plan, to promote cleanliness.
(C) Piers must support the combined loads applied by the
weight of the scale, the weighbridge, plus the maximum
anticipated load on the scale and must distribute these loads
evenly over the underlying ground so that any settlement of
the structure shall be as little as possible and that settlement
shall be uniform throughout the structure.
(D) Reinforcing should extend the entire width of the piers
and be of a minimum schedule consistent with the American
Concrete Guidelines.
(E) Anchor bolts for check stands and load cell stands
shall be of the embedded type or thunderstuds if installed
in accordance with good engineering practice to assure that
those working parts of the scale remain securely anchored
during normal and reasonable use of the scale.
(6) On scales with a mechanical indicating element, the
element shall be mounted on a firm foundation which is
adequate to prevent deflection or vibration.
(7) Approaches to Pit Type Scales.
(A) Vehicle Scales. On the entrance and exit ends of a vehicle
scale there shall be a straight approach a) the width at least the
width of the platform, b) the length at least one-half (1/2) the
length of the platform but not required to be more than forty
feet (40'), and c) not less than ten feet (10') of any approach
adjacent to the platform shall be constructed of concrete or
similar durable material to ensure that this portion remains
smooth and level and in the same plane as the platform.
However, grating of sufficient strength to withstand all loads
equal to the concentrated load capacity of the scale may be
installed in this portion. Any slope in the remaining portion
of the approach shall ensure ease of vehicle access, ease for
testing purposes, and drainage away from the scale.
(B) Axle-Load Scales. At each end of an axle-load scale there
shall be a straight paved approach in the same plane as the
platform. The approaches shall be the same width as the
platform and of sufficient length to insure the level positioning
of vehicles during weight determinations.
(C) Livestock Scales. Approaches shall be of reinforced
concrete. On at least one (1) entrance there shall be a ten-foot
(10') approach at least as wide as the gate with a minimum gate
width of four and one-half feet (4 1/2'), accessible for movement
of test weights to the scale platform. This approach may be on
an incline from the scale platform, but not such that would
hamper the movement of test weights onto the scale platform.
1. Livestock scales installed prior to July 1, 1998, shall be
exempt from the requirements of subsection (7)(C) of this rule.
(D) Railroad Track Scales. Approach rails must be installed
in accordance with requirements as outlined in the AAR Scale
Handbook.
(8) The lever fulcrum stands or load cell stands shall be so
designed, constructed and installed that under any practical
conditions of loading, the resultant force through the bearings
or load cell(s) will fall within the middle third of the length and
width of the base.
(9) Means shall be provided to restrict motion of the
weighbridge or platform, not to exceed one-quarter inch (1/4")
in any horizontal direction unless the manufacturer proves this
unnecessary for a particular design.
(10) Electronic, hydraulic and mechanical indicating elements,
where used, shall be installed in a location and in a manner
to assure continuous accurate performance under all ambient
conditions.
(11) Load cells employed in vehicle scales shall meet the
following minimum standards.
(A) The output characteristics of the load cells shall be such
that they will not cause the systems performance to vary
beyond allowable tolerances; and
(B) Each individual load cell shall be capable of withstanding
loads equal to one hundred fifty percent (150%) of its rated
capacity without change in span calibration. Each load cell
support structure shall be capable of withstanding loads equal
to three hundred percent (300%) of the rated capacity of the cell
without physical failure of the structure.
(12) All cabling between load cells, junction boxes and
electronic instrumentation shall be shielded and grounded as
recommended by the original scale manufacturer. The ground
shall be a copper clad rod which, whenever possible, shall
be driven to a depth of the water table. Connection between
the ground rod and the common ground points of the system
shall be made with heavy copper wire of No. 10 gauge or
larger. All cables shall be insulated with materials having good
nonhygroscopic qualities and stable capacitance between
conductors. All cable connections, as well as the cell itself,
shall be properly protected against moisture penetration. Load
cell cables physically shall be separated from power cables and
never shall be run in the same conduit.
(13) The power source for the electronic instrumentation shall
be free from harmonics and electrical noise transients.
(A) The power source shall be on a separate circuit back to
the distribution transformer with no other loads connected,
unless it can be demonstrated that the other live loads will not
affect the accuracy of the instrumentation.
(B) One (1) side of the power source should be at ground
potential.
(14) Individual requirements of sections (12) and (13) may be
waived if the manufacturer or installer demonstrates other
means of providing adequate protection against moisture,
radio frequency interference (R.F.I.), lightning and power
surges.
(15) Pitless scales installed prior to April 11, 1985, shall be
exempted from the requirements of this rule.
(16) Requirements of section 413.175, RSMo must be met prior to
the actual installation of devices covered in this rule. Following
installation, any device covered in this rule must be calibrated
and placed in service by a registered Missouri scale serviceman
or officially examined by Missouri Weights and Measures
Division before the device can be used in commercial service.
(17) If any provision of these rules is declared invalid, the
validity of the remainder of these rules shall not be affected.
AUTHORITY: section 413.065, RSMo Supp. 1997.* Original rule filed
Jan. 15, 1985, effective April 11, 1985. Amended: Filed April 14, 1994,
effective Sept. 30, 1994. Amended: Filed Nov. 3, 1997, effective May
30, 1998.
*Original authority: 413.065, RSMo 1983, amended 1993, 1994, 1995.