19 MAC Pt. 7, R. 5.01.3
Use of Manufacturer’s Installation Instructions
Cite as 19 Miss. Admin. Code Pt. 7, R. 5.01.3
Use of Manufacturer’s Installation Instructions
A. All new Factory-Built homes shall be installed in accordance with the manufacturer’s home
installation instructions. These instructions may include but are not limited to the following
details:
1. Skirting must have vents and an opening for access to the crawl space and heat tape
outlet.
2. The dryer exhaust vent must terminate outside the home.
3. Combustion air vents may be needed for sealed combustion units and fireplaces.
4. A vapor barrier may be required on the soil.
5. Adequate clearance must be maintained between the soil and wood floor joists.
6. Water supply lines may be required to be insulated.
7. The lot should be properly graded to avoid standing water around and under the home.
8. The air conditioning condensate drain may be specified to have a termination
outside the home.
9. Specifications for utility connections must be followed.
B. For all new and used Factory-Built homes, the skirting, the end wall siding and trim pieces
are not to be installed at the connection point of the end sections until the installer/transporter
has confirmed the following requirements:
1. Floor connection: All floors of multi-section Factory-Built homes shall be securely
fastened together along the entire length of the home such that the width of the gap
between the two halves of the home is one (1) inch or less. Some filler material (APA rated
sheathing (OSB or Plywood) not to exceed ½ inch thickness) are allowed in areas that
exceed the one (1) inch allowable gap. The connections along the floor and any filler
material used, for all new homes, must be in compliance with the manufacturer’s
installation manual.
2. End walls: End walls of multi section Factory-Built homes shall be securely fastened
together with the proper weather seal material installed such that the width of the gap
between the two halves of the home is one (1) inch or less, pursuant to Manufactured Home
Installation Standards 24 CFR 3285.801 (3) and 3285.802 (c). Some filler material (APA
rated sheathing (OSB or Plywood) not to exceed ½ inch thickness) are allowed in areas that
exceed the one (1) inch allowable gap. The connections along the end walls and any filler
material used, for all new homes, must be in compliance with the manufacturer’s
installation manual.
3.
Siding and trim pieces are not to be installed at the connection of the end sections until the
installer/transporter has provided to the retailer and/or State Fire Marshal’s office
photographs of a.) the marriage line gap at each end of the mobile home showing end of
the home with the serial number visible in the photograph and b.) a photograph of a ruler
positioned at the widest portion of the end wall marriage line gap.
4. Any bottom board material that is damaged, during transport, set up and the installation of
the lag bolts along the marriage line of the home, is required to be properly repaired
according to the manufacturer’s installation instructions for all new manufactured homes or
MH-5 instructions on all used manufactured homes for proper repair of the bottom board.