MAC Pt. 18, R. 2.1.9
Third-Party Certifier
Cite as Miss. Admin. Code Pt. 18, R. 2.1.9
Third-Party Certifier.
1.
Advanced treatment systems and other treatment technologies may be installed only if
they have been tested and listed by a third-party certifying program. Such advanced
treatment systems shall be in compliance with standards for Class I systems as defined by
the most current revision of American National Standards Institute/National Sanitation
Foundation (ANSI/NSF) International Standard Number 40, hereby incorporated by
reference. An approved third-party certifying program shall comply with the following
provisions in order for systems which it has certified to be installed in Mississippi:
a.
On and after October 1, 1996, an approved Third-Party certifying program shall
be accredited by the American National Standards Institute (ANSI).
b.
Have established procedures which send representatives to a minimum of 1
distributor of each Manufacturer in Mississippi on an annual basis to conduct
evaluations to assure the distributor of certified advanced treatment systems is
providing proper maintenance, has sufficient replacement parts available and is
maintaining service records.
c.
Notify the Division of the results of monitoring visits to manufacturers and
distributors within 60 calendar days of the conclusion of the monitoring.
d.
Submit completed reports on testing and evaluation of each advanced treatment
system verifying compliance with American National Standards Institute/National
Sanitation Foundation (ANSI/NSF) International Standard Number 40. Such
reports shall include but not be limited to the following:
i.
Materials.
ii.
Design and construction.
iii.
Performance requirement (BOD, TSS, pH).
iv.
Operation and maintenance.
e.
The Third-Party certifying entity must be disassociated with, and have no vested
interest in, the manufacturer to which certification services are provided.
f.
Information including specifications of each system and/or component part of the
system as deemed necessary by the Department for review.
g.
Design, construction and reinforcement must comply and conform to applicable
rules and regulations of Chapter 5, Subchapter 1.
i.
Septic Tanks – The Division shall review, including an on-site inspection,
the plans, specifications, and construction criteria and shall determine
them to be in compliance with the regulation.
h.
Design, construction and reinforcement must comply and conform to applicable
rules and regulations of Chapter 5, Subchapter 1.
i.
Holding Tanks – The Division shall review, including an on-site
inspection, the plans, specifications, and construction criteria and shall
determine them to be in compliance with the regulation.
i.
Design, construction and reinforcement must comply and conform to applicable
rules and regulations of Chapter 5, Subchapter 1.
j.
Non-waterborne System – Third-Party certification that product has successfully
completed testing and listing process as outlined in American National Standards
Institute/National Sanitation Foundation (ANSI/NSF) International Standard
Number 41.
2.
Alternative Wastewater Technology – Treatment and/or disposal systems/products must
be documented, reviewed, and approved by the Division to verify compliance with the
applicable standards. All Manufacturers must provide a copy of installation and/or
homeowner manual(s) for each of their products. Hydraulic calculations on an alternative
system installation on all products that may be required to be pressurized as part of the
dispersal process, including but not limited to Subsurface Drip, Spray Irrigation, Elevated
Sand Mound, and normally gravity-fed dispersal systems that would have to be
pressurized. List of all component parts authorized for use in the installation of the
product, including but not limited to elbows, connectors, geo-textile fabric, and methods
of equal distribution:
a.
Aggregate Replacement System – The Division shall review, including on-site
inspection(s) if deemed necessary, the plans, specifications and construction
criteria and shall determine them to be in compliance with the regulation. The
Division shall require a complete design from primary treatment to disposal for
the minimum and maximum sized system, which shall also include pump
chamber, pump chamber alarm(s), pump(s), filter(s), valve(s), air release(s),
aggregate replacement product and connector(s).
b.
Subsurface Drip – The Division shall review, including on-site inspection(s) if
deemed necessary, the plans, specifications and construction criteria in order to
determine compliance with the regulation. The Division shall require a complete
design from primary treatment to disposal, which shall also include pump
chamber, pump chamber alarm(s), pump(s), filter(s), valve(s), air release(s),
tubing and connector(s). This must be presented as a total package with
hydraulics for the minimum and maximum sized system.
c.
Spray Irrigation – The Division shall review equipment intended to be utilized in
the construction of spray irrigation systems to verify compliance with the
regulation. The Division shall require a complete design from primary treatment
to disposal, to include pump chamber, pump chamber alarm(s), pump(s), filter(s),
valve(s), spray head(s) and connector(s). This must be presented as a total
package with hydraulics for the minimum and maximum sized system.
d.
Alternative Wastewater Technology – All alternative wastewater treatment and/or
disposal systems/products must be documented and reviewed by the Division to
verify compliance with the applicable standards.
3.
Disinfection – The Division shall review, including on-site inspection(s) if deemed
necessary, the plans, specifications and construction criteria and shall determine them to
be in compliance with the regulation. The Division shall require a complete design from
primary treatment to disposal.
4.
Effluent Filter – Design and construction must comply and conform to applicable rules
and regulations of Chapter 5, Subchapter 1.