MAC Pt. 18, R. 3.2.9
Sewage Disposal
Cite as Miss. Admin. Code Pt. 18, R. 3.2.9
Sewage Disposal.
1.
General Provisions: All sewage and other liquid wastes generated within a campground
shall be disposed of in accordance with the Mississippi State Board of Health Regulations
Governing Individual Onsite Wastewater Disposal Systems and/or Mississippi
Department of Environmental Quality, Office of Pollution Control regulations. The
proposed method of sewage disposal shall have the approval of the appropriate authority
prior to the commencement of any construction and shall comply with all appropriate
state laws and regulations.
2.
Recreational Vehicle Waste Disposal Stations:
a.
In all recreational vehicle campgrounds, a minimum of one recreational vehicle
waste disposal station shall be provided for each 50 recreational vehicle stands, or
part thereof, which are not equipped with individual sewer connections.
b.
Each station shall be level, convenient of access from the service road, and shall
provide easy ingress and egress for recreational vehicles.
c.
Construction of Waste Disposal Stations:
i.
Unless other approved means are used, each station shall have a concrete
slab with drain inlet located so as to be on the road (left) side of the
recreational vehicle.
ii.
The slab shall be not less than 3 feet by 3 feet, at least 5 inches thick and
properly reinforced, the surface of which is troweled to a smooth finish
and sloped from each side inward to a sewer inlet.
iii.
The sewer inlet shall consist of a 4-inch, self-closing foot-operated hatch
of approved material with cover milled to fit tight [see Figure 1, Sewer
Inlet Cover]. The hatch body shall be set in the concrete of the slab with
the lip of the opening flush with its surface to facilitate the cleansing of the
slab with water. The hatch shall be properly connected to a sewer inlet
which shall discharge to an approved sanitary sewage disposal facility.
d.
Flushing Facilities:
i.
At all waste disposal stations a means for flushing the recreational vehicle
holding tank and the slab shall be provided. It shall consist of a piped
supply of water under pressure, terminating in a valved outlet located and
installed so as to minimize damage by automobiles or recreational
vehicles. The flushing device shall consist of a properly supported riser
terminating at least 2 feet above the ground surface, with a 3/4-inch valved
outlet to which is screwed a flexible hose [see Figure 2, Flushing Device].
ii.
The water supply to the flushing device shall be protected from backflow
and back-siphonage, and be equipped with a retractable, spring coiled
water delivery device.
iii.
Adjacent to the flushing arrangement there shall be posted a sign of
durable material, not less than 2 feet by 2 feet in size, and inscribed
thereon in clearly legible letters shall be: “DANGER – NOT TO BE
USED FOR DRINKING OR DOMESTIC PURPOSES.”