MAC Pt. 18, R. 5.4.10
Distribution of Effluent
Cite as Miss. Admin. Code Pt. 18, R. 5.4.10
Distribution of Effluent.
1.
When a change in elevation of the disposal trench is required, a distribution box,
connecting lateral or crossover must be used. At the point where a crossover line leaves a
lateral, the trench for the crossover line shall be dug no deeper than the top of the
aggregate in the preceding trench so that an undisturbed block of earth will remain in
place for the full depth of the aggregate. The distribution box shall be level and supply all
lines equally. Field lines must be equal lengths when served by one distribution box.
2.
Distribution boxes may be used to connect the effluent line to the effluent distribution
lines. Non-perforated rigid pipe shall exit the distribution box for a minimum of five feet
at level grade before the effluent distribution line (perforations) begins. [See Figure 12.]
3.
Crossover lines shall be laid on undisturbed earth. The invert of the crossover must be at
least four inches lower than the invert of the septic tank outlet line:
a.
Crossovers shall be constructed as shown in Figure 10.
Source: Miss. Code Ann. § 41-67-3.
TABLE 1 - SETBACK REQUIREMENTS FROM SENSITIVE WATER (Aggregate Systems)
Minimum Distance from the Water Edge
Soil Textural Class
Slope of Less Than 8 Percent
Slope of More Than 8 Percent
Gravel
NOT APPLICABLE
Coarse Sand
50 feet
50 feet
Medium Sand
50 feet
50 feet
Fine Sand
50 feet
50 feet
Loamy Sand
50 feet
50 feet
Sandy Loam
50 feet
50 feet
Light Loam
50 feet
50 feet
Heavy Loam
50 feet
50 feet
Silt Loam
50 feet
50 feet
Sandy Clay Loam
50 feet
50 feet
Light Clay Loam
50 feet
50 feet
Heavy Clay Loam
50 feet
50 feet
Light Silty Clay Loam
50 feet
50 feet
Heavy Silty Clay Loam
50 feet
50 feet
Sandy Clay
50 feet
50 feet
Silty Clay
50 feet
50 feet
Clay
50 feet
50 feet
The effluent disposal setback is based on the soil texture of the horizon in which the absorption trench or bed is to be placed. These
setbacks are to be used on all individual on-site wastewater disposal systems except spray irrigation disposal and overland
discharge.
Source: Miss. Code Ann. § 41-67-3.
TABLE 2 - SIZING: AGGREGATE (Gravel, Crushed Stone, Tire Chips, or other approved media)
Results of the Soil and Site Evaluation
Soil Textural Class
Ribbon Lengths
(Inches)
EPA Manual Application
Rate GPD/ Ft2
Absorption Area Per
Bedroom (3’ Trench)*
Additional Absorption
Area Over 2 Persons Per
Bedroom
Ft2
Lf
Ft2
Lf
Gravel
-
-
NOT SUITABLE
Coarse Sand
-
1.2
Medium Sand
-
1.2
Fine Sand
-
0.8
Loamy Sand
-
0.8
Sandy Loam
<.5
0.6
Light Loam
<.5
0.6
Heavy Loam
.5 – 1
0.45
Silt Loam
<1
0.45
Sandy Clay Loam
1 – 2
0.45
Light Clay Loam
1 – 1.5
0.30
Heavy Clay Loam
1.5 – 2.0
0.20
Light Silty Clay Loam
1 – 1.5
0.30
Heavy Silty Clay Loam
1.5 – 2.0
0.20
Sandy Clay
>2.0
-
NOT SUITABLE
Silty Clay
>2.0
-
NOT SUITABLE
Clay
>2.0
-
NOT SUITABLE
*Bedroom is equivalent to 130 GPD.
Source: Miss. Code Ann. § 41-67-3.
FIGURE 6 – Conventional Subsurface Absorption
Source: Miss. Code Ann. § 41-67-3.
FIGURE 7 – Ultra Shallow Absorption Field
Source: Miss. Code Ann. § 41-67-3.
FIGURE 8 – Conventional Absorption Bed
Source: Miss. Code Ann. § 41-67-3.
FIGURE 9 – Effluent Distribution for Absorption Beds
Source: Miss. Code Ann. § 41-67-3.
FIGURE 10 – Connection Lateral (Spillovers)
Source: Miss. Code Ann. § 41-67-3
FIGURE 11 – Conventional Absorption Bed
Source: Miss. Code Ann. § 41-67-3.
FIGURE 12 – Distribution Box