MAC Pt. 18, R. 5.6.10
Design of Elevated Sand Mound Disposal System
Cite as Miss. Admin. Code Pt. 18, R. 5.6.10
Design of Elevated Sand Mound Disposal System.
1.
These guidelines present requisite site characteristics, design criteria, and construction
techniques for on-site mound sewage systems. These guidelines provide a systematic
approach to mound system design for typical domestic household wastewater. For
systems serving other than single family dwellings the designer is cautioned that simple
extrapolation of this information may not be appropriate.
2.
When addressing wastewater flows that differ from a septic tank, such as those
characterized by high biological oxygen demand (BOD5), total suspended solids (TSS),
or oil and grease, the elevated sand-mound has inherent limitations. Wastewater from
non-domestic sources should be evaluated on a case-by-case basis, to determine the
amount of pretreatment necessary to apply to an elevated sand mound. The wastewater
applied to an elevated sand mound should not exceed 220 mg/l BOD5 or 145 mg/l TSS
(no TSS particles should be retained on a 1/8th inch screen).
3.
Mounds are an excellent treatment and disposal choice on appropriate sites, but they are
not very forgiving. Special attention must be given to siting, design, pre-construction
planning, site preparation, filter media selection, construction and maintenance of these
systems. Quality control throughout the process cannot be overemphasized.