MAC Pt. 18, R. 5.7.10
Minimum Specifications for the Spray Field
Cite as Miss. Admin. Code Pt. 18, R. 5.7.10
Minimum Specifications for the Spray Field.
1.
Spray irrigation systems may not be installed in drain ways, swamps, marshes,
floodplain, concave landscape positions or other areas which would be prohibited.
2.
Treated effluent shall be sprayed evenly over the entire spray field area with non-
overlapping patterns. The spray field shall consist of a minimum of three (3) spray heads.
3.
The effluent distribution system shall be designed, constructed and maintained to provide
for even distribution of effluent throughout the spray field.
4.
Surface runoff of sprayed effluent from the spray field area shall not be permitted.
Rainwater shall be diverted away from the spray field area.
5.
The spray field area shall be designed and operated to prevent surface accumulation of
sprayed effluent.
6.
In order to prevent entrapped air causing serious problems, pipelines shall be routed on
contour, downhill or even uphill but not up and downhill along the same section of pipe.
7.
The size of the spray field area shall be determined by soil texture and slope of the site to
be sprayed. [See Table 16.]
Source: Miss. Code Ann. § 41-67-3.
TABLE 16 – SIZING: Spray Irrigation
Results of the Soil and Site Evaluation
Soil Textural Class
Ribbon
Lengths
(Inches)
Spray Factor
(Sq-Ft/GPD)*
Absorption Area in Ft2/Bedroom**
Additional Absorption Area Over
2 Persons Per Bedroom
Slope
Slope
0 to 8 %
9 to 12%
13 to 16%
0 to 8 %
9 to 12%
13 to 16%
Gravel
NOT SUITABLE
Coarse and Medium
Sand
Fine and Loamy Sand
Sandy Loam
< 0.5
5.34
1,040
Loam
Silt Loam
Sandy Clay Loam
< 0.5 – 1.0
< 0.5- 1.0
1.0 – 2.0
10.67
Silt Clay Loam
Clay Loam
Sandy Clay
1.0 – 2.0
1.0 – 2.0
> 2.0
21.4
Silty Clay
Clay
> 2.0
53.46
11588
*Spray Factor assumes a 0%-8% slope. To estimate required disposal area, multiply GPD by the Spray Factor. Ex: 500 GPD x 21.4
(Clay Loam soils) = 10,700 sq-ft spray footprint required.
**Bedroom is equivalent to 130 GPD.
Source: Miss. Code Ann. § 41-67-3.
TABLE 17 – FILL MATERIAL REQUIREMENT
Seasonal High Water Table Depth
(inches)
…with a Restrictive Horizon/Layer
(inches)
…without a Restrictive Horizon/Layer
(inches)
-
-
-
-
-
-
-
-
Source: Miss. Code Ann. § 41-67-3.
Advanced Treatment System
Pre-treatment Unit (if applicable)
Flex tubing/Swing Joint Assembly
Generator
FIGURE 22 - SPRAY IRRIGATION SYSTEM
Pump Chamber (appropriately sized)
Spray heads (3 minimum)
Source: Miss. Code Ann. § 41-67-3.
FIGURE 23 - FLEX TUBE/SWING JOINT ASSEMBLY
Source: Miss. Code Ann. § 41-67-3.
Subchapter 8: Reserved.