15 MAC Pt. 21, R. 1.11.24
Reciprocal Recognition of Licenses
Cite as 15 Miss. Admin. Code Pt. 21, R. 1.11.24
Reciprocal Recognition of Licenses. The out-of-state licensee shall comply with
the provisions of 1.3.26 of these regulations.
SOURCE: Miss. Code Ann. §45-14-3
APPENDIX A
Acceptable Surface Contamination Levels For
Norm
RADIONUCLIDE
a
U-nat, U-235,
AVERAGE
bcf
MAXIMUM
bdfg
REMOVABLE
bcef
U-238, and asso-
ciated products
(including Po-210),
except Ra-226,
Th-230, Ac-227, and
Pa-231
5,000 dpm
alpha/100 cm2
15,000 dpm
alpha/100 cm2
1,000 dpm
alpha/100 cm2
Transuranics, Ra-226,
Ra-228, Th-230
Th-228, Pa-231,
Ac-227
100 dpm/
100 cm2
300 dpm/
100 cm2
20 pm/
100 cm2
Th-nat, Th-232,
Ra-223, Ra-224,
U-232
1,000 dpm/
100 cm2
3,000 dpm/
100 cm2
200 dpm/
100 cm2
Beta-gamma emitters
(radionuclides with decay
modes other than alpha
emission or spontaneous
fission, including
Pb-210), except
others noted above.
5,000 dpm beta,
gamma/100 cm2
15,000 dpm beta,
gamma/100 cm2
1,000 dpm beta,
gamma/100 cm2
(a)
Where surface contamination by both alpha and beta-gamma emitting radionuclides
exists, the limits established for alpha and beta-gamma emitting radionuclides should
apply independently.
(b)
As used in this table, dpm (disintegrations per minute) means the rate of emission by
radioactive material as determined by correcting the counts per minute observed by an
appropriate detector for background, efficiency, and geometric factors associated with the
instrumentation.
(c) Measurements of average contamination levels should not be averaged over more than
one square meter. For objects of less surface area, the average should be derived for
each object.
(d) The maximum contamination level applies to an area of not more than 100 cm2.
(e) The amount of removable radioactive material per 100 cm2 of surface area should be
determined by wiping that area with dry filter or soft absorbent paper, applying moderate
pressure, and assessing the amount of radioactive material on the wipe with an appropriate
instrument of known efficiency. When removable contamination on objects of less
surface area is determined, the pertinent levels should be reduced proportionally and the
entire surface should be wiped.
(f)
The average and maximum radiation levels associated with surface contamination
resulting from beta-gamma emitters should not exceed 0.2 mrad/hr (2 µGy/hr) at 1 cm
and 1.0 mrad/hr (10 µGy/hr) at 1 cm respectively, measured through not more than 7
milligrams per square centimeter of total absorber.
(g) Equipment containing NORM shall not exceed a maximum radiation exposure level of 25
microroentgens per hour above background radiation at any accessible point.
Subchapter 12 Licensing And Radiation Safety Requirements For Irradiators