15 MAC Pt. 21, R. 1.9.8
Particle Accelerator Controls and Interlock Systems
Cite as 15 Miss. Admin. Code Pt. 21, R. 1.9.8
Particle Accelerator Controls and Interlock Systems.
1.
Instrumentation, readouts, and controls on the particle accelerator control console
shall be clearly identified and easily discernible.
2.
Each entrance into a target room or other high radiation area shall be provided
with a safety interlock that shuts down the machine under conditions of barrier
penetration.
3.
Each safety interlock shall be on a circuit which shall allow it to operate
independently of all other safety interlocks.
4.
All safety interlocks shall be designed so that any defect or component failure
in the safety interlock system prevents operation of the accelerator.
5.
When a safety interlock system has been tripped, it shall only be possible to
resume operation of the accelerator by manually resetting controls at the position
where the safety interlock has been tripped and, lastly, at the main control console.
6.
A scram button or other emergency power cutoff switch shall be located and
easily identifiable in all high radiation areas. Such a cutoff switch shall
include a manual reset so that the accelerator cannot be restarted from the
accelerator control console without resetting the cutoff switch.