18 MAC Pt. 310, R. 9.7
Physical Attributes of Partner Provider Facility – Facilities must be handicapped
Cite as 18 Miss. Admin. Code Pt. 310, R. 9.7
Physical Attributes of Partner Provider Facility – Facilities must be handicapped
accessible. The arrangement, appearance, and interior areas of the facility must be
similar to those of a home environment. The facility must be decorated and furnished
to create a home-like environment. Furnishings must be safe, attractive, easy to
maintain, and selected for their suitability to the age and development of the children
in care.
1. Doors. When the door is in the fully open position, the width of doorway
must not be fewer than thirty-two (32) inches wide. Locks on exit doors must
not require the use of a key for operation from inside the building.
2. Stairs. Doors opening onto stairs must have a landing at a minimum of the
width of the door. The minimum headroom on stairs to clear all obstruction
must be six feet and eight inches tall (6' 8"). The width of stairs must not be
less than thirty-two (32) inches. The minimum tread depth of each step of
the stairs must not be less than nine (9) inches. The maximum height of risers
in each step must not exceed eight (8) inches.
3. Guardrails and Handrails. Guards and handrails must be provided on both
sides of all stairs and ramps rising more than thirty (30) inches above the
floor or grade. Guards and handrails must continue for the full length of the
ramp or stairs. Handrails must provide at least two (2) inches between the
inner side of the rail and support wall. Handrails must not be more than
thirty-four (34) inches above the step or ramp nor less than thirty (30) inches.
4. Ramps, Platforms, and Landings. Ramps, platforms and landings associated
with the guards and handrails must be designed for not less than one hundred
(100) pounds per square foot and have a slip-resistant surface.
5. Exits. Exits must be accessible at all times. No stove or heater must block an
escape route.