Cite as Mont. Admin. R. 24.138.3225

24.138.3205 FACILITY STANDARDS (1) A general anesthesia facility under these rules must contain a minimum of equipment, supplies and drugs, including, but not limited to, the following: (a) a positive pressure oxygen delivery system; (b) stethoscope and sphygmomanometer; (c) laryngoscope, endotracheal tubes and a Magill forcep; (d) oral pharyngeal and/or nasopharyngeal airways; (e) electrocardiac monitor and defibrillator; (f) appropriate drugs for emergencies to include drugs to provide advanced cardiac life support; (g) a precordial stethoscope; (h) pulse oximeter; and (i) suction devices. (2) A conscious sedation facility under these rules must contain a minimum of equipment, supplies, and drugs, including, but not limited to, the following: (a) a positive pressure oxygen delivery system; (b) precordial stethoscope; (c) pulse oximeter; (d) stethoscope and sphygmomanometer; (e) oral pharyngeal and/or nasopharyngeal airways; (f) appropriate drugs for emergencies; and (g) suction devices. (3) A facility in which nitrous oxide/oxygen, used alone or in conjunction with a single oral sedative agent, is administered must contain a minimum of equipment and supplies appropriate to meet emergencies.