ARM 17.36.320

ARM 17.36.320. SEWAGE SYSTEMS: DESIGN

SupersededLast amended: 2003Length: 498 wordsOfficial source

Cite as Mont. Admin. R. 17.36.320

(1) All components of subsurface sewage treatment systems must be designed and installed in accordance with department Circular DEQ-4. As indicated on Table 2 of this rule, public systems and multi-user systems with design flows greater than or equal to 2500 gallons per day must be designed by a registered professional engineer. (2) A minimum separation of at least four feet of natural soil must exist between the infiltrative surface or the liner of a lined system and a limiting layer, except that at least six feet of natural soil must exist on a steep slope (15% to 25%) . (3) The proposed subsurface sewage treatment area must include an area for 100% replacement of the system. Unless a waiver is approved by the department pursuant to ARM 17.36.601 , the replacement area must meet the same requirements as the primary area. If the replacement area is not immediately adjacent to the primary area, or if the department indicates to the applicant that it has reason to believe that site conditions for the replacement area may vary from those for the primary area, the applicant shall submit adequate evidence of the suitability of the replacement area. TABLE 2 ALLOWABLE SYSTEMS, REQUIREMENTS YES - Systems that are allowed NO - Systems that are not allowed DEQ-4 System Public: > 5000 gpd (1) (7) Public or Multiple-user: ³ 2500 gpd and £ 5000 gpd (2) (7) Public or Multiple-user: < 2500 gpd (3) Individual/Shared: (6) Standard Absorption Trench NO NO YES YES At-Grade Systems NO NO YES YES Gravelless YES YES YES YES Deep Trench NO NO NO YES Elevated Sand Mound YES YES YES YES Evapotranspiration (ET) Systems NO NO NO NO (5) ET-Absorption NO YES YES YES Intermittent Sand Filters YES YES YES YES Recirculating Sand Filters YES YES YES YES Recirculating Trickling Filters YES YES YES YES YES - Systems that are allowed NO - Systems that are not allowed DEQ-4 System Public: > 5000 gpd (1) Public or Multiple-user: ³ 2500 gpd and £ 5000 gpd (2) Public or Multiple-user: < 2500 gpd (3) Individual/ Shared: (6) Chemical Nutrient Reduction; Aerobic Sewage Treatment Systems NO (5) NO (5) NO (5) NO (4) (5) Pressure Distribution YES YES YES YES Sand-lined Absorption Trenches NO YES YES YES Experimental Systems NO (5) NO (5) NO (5) NO (5) (1) Public systems with design flow greater than 5000 gallons per day (gpd) . (2) Public or multiple-user systems with design flow greater than or equal to 2500 gpd and less than or equal to 5000 gpd. (3) Public or multiple-user systems with design flow less than 2500 gpd. (4) Means of securing continuous operation and maintenance of these systems must be approved by the reviewing authority prior to DEQ approval. (5) May be allowed by waiver, pursuant to ARM 17.36.601 . (6) Individual or shared commercial sewage systems that have a design flow greater than 700 gpd shall be considered multi-user. (7) Must be designed by a professional engineer.
ARM 17.36.320: ARM 17.36.320. SEWAGE SYSTEMS: DESIGN | Justis AI