(1) A person may not conduct asbestos repair procedures for an asbestos project unless accredited by the department as an asbestos project worker or asbestos project contractor/supervisor. (2) A person conducting asbestos repair procedures for an asbestos project shall: (a) apply amended water to the ACM to reduce airborne asbestos concentrations; (b) remove or repair loose or hanging ACM; (c) ensure that the repaired ACM is sufficiently repaired to prevent the release of asbestos; (d) ensure that the repaired ACM is conspicuously marked or labeled to warn persons of its presence; and (e) meet the requirements of ARM 17.74.357.