NDAC 74-06-01-02
Determination of dockage
Cite as N.D. Admin. Code ยง 74-06-01-02
1.
Determination by hand sieves shall be by 6x22, 6x21, 6x20, 6x18 mesh per inch
[2.54 centimeters] wire sieves and 5/64, 5.5/64, 6/64, 6.5/64, 7/64, 7.5/64 inch round hole
sieves.
2.
Determination by machine shall be by the Carter dockage tester for aspiration.
a.
Dockage determination shall be made on the basis of a representative portion of
five hundred grams of rapeseed cut from the sample as a whole as follows:
(1)
The sample is scalped on the appropriate round hole sieve which will achieve
maximum removal of large foreign material with minimum loss of rapeseed.
(2)
The scalped sample is run over the Carter dockage tester for aspiration using feed 3
and air 5 settings, using the 000 plastic riddle.
(3)
The sample is then screened on the wire mesh sieve which achieves maximum
cleanout of weed seeds and other foreign material with a minimum loss of
reasonably sound rapeseed.
(4)
A representative subsample of not less than twenty grams properly divided from the
cleaned sample is handpicked for the remaining inseparable foreign matter (matter
other than rapeseed) which is easily distinguished by visual inspection.
b.
Computation of total dockage shall be as follows:
(1)
The percent of dockage removed by the hand sieves and the Carter dockage tester
shall be computed on the basis of the sample as a whole. The percentage of
dockage removed by handpicking shall first be computed on the basis of the
handpicked portion and then on the basis of the percentage of the mechanically
cleaned and hand-sieved rapeseed.
For example, if in a given sample, the dockage removed by mechanical means and
hand sieves is ten percent, the percentage of mechanically cleaned and
hand-sieved seed (or rapeseed) is ninety percent. If the percentage of dockage
removed by handpicking is two percent of the handpicked portion, the two percent
shall be multiplied by nine-tenths to obtain the percent of handpicked dockage,
one and eight-tenths. The percent of mechanically and hand-sieved dockage,
ten percent is then added to the handpicked dockage, one and eight-tenths percent
to give a total dockage of eleven and eight-tenths percent.
(2)
Dockage is assessed to the nearest one-tenth of one percent. The results of
individual cleaning procedures will be recorded on the reverse side of the sample
tickets.
Example:
3.4% 5/64 round holes, 4% 6x21 wire, 1.7% air