NDAC 33.1-10-15-02
Definitions
Cite as N.D. Admin. Code ยง 33.1-10-15-02
As used in this chapter, the following definitions apply:
1.
"Absorbed dose (D)" means the mean energy imparted by ionizing radiation to matter.
Absorbed dose is determined as the quotient of dE by dM, where dE is the mean energy
imparted by ionizing radiation to matter of mass dM. The SI unit of absorbed dose is joule per
kilogram and the special name of the unit of absorbed dose is the gray (Gy). The previously
used special unit of absorbed dose (rad) is being replaced by the gray.
2.
"Absorbed dose rate" means absorbed dose per unit time, for machines with timers, or dose
monitor unit per unit time for linear accelerators.
3.
"Accelerator-produced material" means any material made radioactive by exposing it in a
particle accelerator.
4.
"Accessible surface" means surface of equipment or of an equipment part that can be touched
by persons without the use of a tool.
5.
"Activity" means the rate of disintegration or transformation or decay of radioactive material.
The units of activity are the becquerel (Bq) and the curie (Ci).
6.
"Added filtration" means any filtration which is in addition to the inherent filtration.
7.
"Air kerma (K)" means the kinetic energy released in air by ionizing radiation. Kerma is
determined as the quotient of dE by dM, where dE is the sum of the initial kinetic energies of
all the charged ionizing particles liberated by uncharged ionizing particles in air of mass dM.
The SI unit of air kerma is joule per kilogram and the special name for the unit of kerma is the
gray (Gy).
8.
"Barrier" (see "protective barrier").
9.
"Beam axis" means the axis of rotation of the beam-limiting device from the source through
the centers of the x-ray field.
10.
"Beam-limiting device" means a device which provides a means to restrict the dimensions of
the useful beam.
11.
"Beam-monitoring system" means a system designed and installed in the radiation head to
detect and measure the radiation present in the useful beam.
12.
"Beam-scattering foil" means a thin piece of material (usually metallic) placed in the beam to
scatter a beam of electrons in order to provide a more uniform electron distribution in the
useful beam.
13.
"Bent-beam linear accelerator" means a linear accelerator geometry in which the accelerated
electron beam must change direction by passing through a bending magnet.
14.
"Brachytherapy" means a method of radiation therapy in which sealed sources are utilized to
deliver a radiation dose at a distance of up to a few centimeters, by surface, intracavitary, or
interstitial application.
15.
"Calibration" means the determination of:
a.
The response or reading of an instrument relative to a series of known radiation values
over the range of the instrument; or
b.
The strength of a source of radiation relative to a standard.
16.
"CFR" means the Code of Federal Regulations.
17.
"Changeable filters" means any filter, exclusive of inherent filtration, which can be removed
from the useful beam through any electronic, mechanical, or physical process.
18.
"Contact therapy system" means an x-ray system used for therapy with the x-ray tube port
placed in contact with or within five centimeters of the surface being treated.
19.
"Department" means the department of environmental quality.
20.
"Detector" (see "radiation detector").
21.
"Dose" is a generic term that means absorbed dose, dose equivalent, effective dose
equivalent, committed dose equivalent, committed effective dose equivalent, total organ dose
equivalent, or total effective dose equivalent. For purposes of these rules, "radiation dose" is
an equivalent term.
22.
"Dose equivalent HT" means the product of the absorbed dose in tissue, quality factor, and all
other necessary modifying factors at the location of interest. The units of dose equivalent are
the sievert (Sv) and rem.
23.
"Dose monitor unit (DMU)" means a unit response from the beam-monitoring system from
which the absorbed dose can be calculated.
24.
"Electron applicator" means any accessory device utilized during electron therapy which
determines the extent of the treatment area at a given distance from the source.
25.
"Entrance" means any opening through which an individual or extremity of an individual could
gain access to radiation areas or to licensed or registered radioactive materials. This includes
entry or exit portals of sufficient size to permit human entry, irrespective of their intended use.
26.
"Exposure" means being exposed to ionizing radiation or to radioactive material.
27.
"External beam radiation therapy" means therapeutic irradiation in which the source of
radiation is at a distance from the body.
28.
"Field-flattening filter" means a filter used to homogenize the absorbed dose rate over the
radiation field.
29.
"Filter" means material placed in the useful beam to absorb preferentially selected radiations.
30.
"Gantry" means that part of a radiation therapy system supporting and allowing movements of
the radiation head about a center of rotation.
31.
"Gray (Gy)" means the SI unit of absorbed dose, kerma, and specific energy imparted equal to
one joule per kilogram. The previous unit of absorbed dose (rad) is being replaced by the gray.
[1 Gy = 100 rad].
32.
"Half-value layer (HVL)" means the thickness of a specified material which attenuates
x-radiation or gamma radiation to an extent such that the air kerma rate, exposure rate, or
absorbed dose rate is reduced to one-half of the value measured without the material at the
same point.
33.
"Healing arts" means diagnostic or healing treatment of human and animal maladies, including
the following which are duly licensed by the state of North Dakota for the lawful practice of:
medicine and its associated specialties, dentistry, veterinary medicine, osteopathy,
chiropractic, and podiatry.
34.
"Individual" means any human being.
35.
"Inspection" means an official examination or observation, including tests, surveys, and
monitoring to determine compliance with rules, regulations, orders, requirements, and
conditions of the department.
36.
"Interlock" means a device preventing the start or continued operation of equipment unless
certain predetermined conditions prevail.
37.
"Interruption of irradiation" means the stopping of irradiation with the possibility of continuing
irradiation without resetting of operating conditions at the control panel.
38.
"Irradiation" means the exposure of a living being or matter to ionizing radiation.
39.
"Isocenter" means the center of the sphere through which the useful beam axis passes while
the gantry moves through its full range of motions.
40.
"Kilovolt (kV) [kilo electron volt (keV)]" means the energy equal to that acquired by a particle
with one electron charge in passing through a potential difference of one thousand volts in a
vacuum. [Note: Current convention is to use kV for photons and keV for electrons.]
41.
"Lead equivalent" means the thickness of lead affording the same attenuation, under specified
conditions, as the material in question.
42.
"Leakage radiation" means radiation emanating from the diagnostic or therapeutic source
assembly except for:
a.
The useful beam; and
b.
Radiation produced when the exposure switch or timer is not activated.
43.
"Light field" means the area illuminated by light, simulating the radiation field.
44.
"mA" means milliampere.
45.
"Medical use" means the intentional internal or external administration of radiation or
radioactive material or the radiation therefrom to patients or human research subjects under
the supervision of an authorized user as defined in chapter 33.1-10-07.2-01 [10 CFR 35.2].
46.
"Megavolt (MV) [megaelectron volt (MeV)]" means the energy equal to that acquired by a
particle with one electron charge in passing through a potential difference of one million volts
in a vacuum. [Note: Current convention is to use MV for photons and MeV for electrons.]
47.
"Monitor unit (MU)" (see "dose monitor unit").
48.
"Monitoring" means the measurement of radiation and the use of the results of these
measurements to evaluate potential exposures and doses. For purposes of these rules,
"radiation monitoring" and "radiation protection monitoring" are equivalent terms.
49.
"Moving beam radiation therapy" means radiation therapy with any planned displacement of
radiation field or patient relative to each other, or with any planned change of absorbed dose
distribution. It includes arc, skip, conformal, intensity modulation, and rotational therapy.
50.
"Nominal treatment distance" means:
a.
For electron irradiation, the distance from the scattering foil, virtual source, or exit window
of the electron beam to the entrance surface of the irradiated object along the central
axis of the useful beam.
b.
For x-ray irradiation, the virtual source or target to isocenter distance along the central
axis of the useful beam. For non-isocentric equipment, this distance shall be that
specified by the manufacturer.
51.
"Patient" means an individual or animal subjected to radiation for the purposes of diagnosis or
treatment.
52.
"Peak tube potential" means the maximum value of the potential difference across the x-ray
tube during an exposure.
53.
"Periodic quality assurance check" means a procedure which is performed to ensure that a
previous calibration continues to be valid.
54.
"Person" means any individual, corporation, partnership, firm, association, trust, estate, public
or private institution, group, agency, political subdivision of this state, any other state or
political subdivision or agency thereof, and any legal successor, representative, agent, or
agency of the foregoing, other than the commission, or any successor thereto and other than
federal government agencies licensed by the commission or any successor thereto.
55.
"Phantom" means a volume of material behaving in a manner similar to tissue with respect to
absorption and scattering of the ionizing radiation in question.
56.
"Physician" means a medical doctor or doctor of osteopathy licensed by a state or territory of
the United States, the District of Columbia, or the Commonwealth of Puerto Rico to prescribe
drugs in the practice of medicine.
57.
"Practical range of electrons" corresponds to classical electron range where the only
remaining contribution to dose is from bremsstrahlung x-rays. A further explanation may be
found in "clinical electron beam dosimetry: report of AAPM radiation therapy committee task
group 25" [Medical Physics 18(1): 73-109, Jan./Feb. 1991] and ICRU report 35, "radiation
dosimetry: electron beams with energies between 1 and 50 MeV", international commission
on radiation units and measurements, September 15, 1984.
58.
"Primary dose monitoring system" means a system which will monitor the useful beam during
irradiation and which will terminate irradiation when a preselected number of dose monitor
units have been delivered.
59.
"Primary protective barrier" (see "protective barrier").
60.
"Protective barrier" means a barrier of radiation absorbing materials used to reduce radiation
exposure. The types of protective barriers are as follows:
a.
"Primary protective barrier" means the material, excluding filters, placed in the useful
beam.
b.
"Secondary protective barrier" means the material which attenuates stray radiation.
61.
"Qualified expert" means an individual having the knowledge, training, and experience to
measure ionizing radiation, to evaluate safety techniques, and to advise regarding radiation
protection needs, for example, individuals certified in the appropriate field by the American
board of medical physics, or those having equivalent qualifications. With reference to the
calibration of radiation therapy equipment, "qualified expert" means an individual having, in
addition to the above qualifications, training and experience in the clinical applications of
radiation physics to radiation therapy, for example, individuals certified in therapeutic
radiological physics or x-ray and radium physics by the American board of radiology, or those
having equivalent qualifications.
62.
"Rad" means the special unit of absorbed dose. One rad is equal to an absorbed dose of one
hundred erg per gram or one one-hundredth joule per kilogram (0.01 gray).
63.
"Radiation" means alpha particles, beta particles, gamma rays, x-rays, neutrons, high-speed
electrons, high-speed protons, and other particles capable of producing ions. For purposes of
these rules, ionizing radiation is an equivalent term. Radiation, as used in these rules, does
not include nonionizing radiation, such as radiowaves or microwaves, visible, infrared, or
ultraviolet light.
64.
"Radiation detector" means a device which in the presence of radiation provides a signal or
other indication suitable for use in measuring one or more quantities of incident radiation.
65.
"Radiation exposure" means the quotient of dQ by dm where "dQ" is the absolute value of the
total charge of the ions of one sign produced in air when all the electrons (negatrons and
positrons) liberated by photons in a volume element of air having mass "dm" are completely
stopped in air. The SI unit of radiation exposure is the coulomb per kilogram (C/kg). (See
section 33.1-10-01-14 units of exposure, dose, and activity for the special unit equivalent
"roentgen" (R).)
66.
"Radiation exposure rate" means the radiation exposure per unit of time, such as R/min,
mR/h, etc.
67.
"Radiation field" (see "useful beam").
68.
"Radiation head" means the structure from which the useful beam emerges.
69.
"Radiation machine" means any device capable of producing radiation except those devices
with radioactive material as the only source of radiation.
70.
"Radiation therapy physicist" means an individual qualified in accordance with subsection 4 of
section 33.1-10-15-03.
71.
"Radiation therapy simulation system" means a radiographic or fluoroscopic x-ray system
intended for localizing the volume to be exposed during radiation therapy and confirming the
position and size of the therapeutic irradiation field.
72.
"Redundant beam-monitoring system" means a combination of two dose monitoring systems
in which each system is designed to terminate irradiation in accordance with a preselected
number of dose monitor units.
73.
"Registrant" means any person who is registered with the department and is legally obligated
to register with the department pursuant to this article and North Dakota Century Code
chapter 23.1-03.
74.
"Registration" means the notification of the department of possession of a source of radiation
and the furnishing of information with respect thereto, in accordance with North Dakota
Century Code chapter 23.1-02.
75.
"Rem" (see "sievert").
76.
"Restricted area" means an area, access to which is limited by the licensee or registrant for
the purpose of protecting individuals against undue risks from exposure to sources of radiation
or radioactive material. "Restricted area" does not include areas used as residential quarters,
but separate rooms in a residential building may be set apart as a restricted area.
77.
"Scattered radiation" means radiation that, during passage through matter, has been deviated
in direction.
78.
"Secondary dose-monitoring system" means a system which will terminate irradiation in the
event of failure of the primary dose-monitoring system.
79.
"Secondary protective barrier" (see "protective barrier").
80.
"Shadow tray" means a device attached to the radiation head to support auxiliary
beam-blocking material.
81.
"Shutter" means a device attached to the tube housing assembly which can intercept the
entire cross-sectional area of the useful beam and which has a lead equivalency not less than
that of the tube housing assembly.
82.
"Sievert (Sv)" means the SI unit of dose equivalent. The unit of dose equivalent is the joule per
kilogram. The previous unit of dose equivalent (rem) is being replaced by the sievert. [1 Sv =
100 rem].
83.
"Source" means the region or material, or both, from which the radiation emanates.
84.
"Source-skin distance (SSD)" (see "target-skin distance").
85.
"Stationary beam radiation therapy" means radiation therapy without displacement of one or
more mechanical axis relative to the patient during irradiation.
86.
"Stray radiation" means the sum of leakage and scattered radiation.
87.
"Target" means that part of an x-ray tube or accelerator onto which a beam of accelerated
particles is directed to produce ionizing radiation or other particles.
88.
"Target-skin distance (TSD)" means the distance measured along the beam axis from the
center of the front surface of the x-ray target or electron virtual source, or both, to the surface
of the irradiated object or patient.
89.
"Tenth-value layer (TVL)" means the thickness of a specified material which attenuates
x-radiation or gamma radiation to an extent such that the air kerma rate, exposure rate, or
absorbed dose rate is reduced to one-tenth of the value measured without the material at the
same point.
90.
"Termination of irradiation" means the stopping of irradiation in a fashion which will not permit
continuance of irradiation without the resetting of operating conditions at the control panel.
91.
"Test" means a method for determining the characteristics or condition of sources of radiation
or components thereof. "Test" may also mean the process of verifying compliance with this
article.
92.
"Therapeutic radiation machine" means x-ray or electron-producing equipment designed and
used for external beam radiation therapy.
93.
"Tube" means an x-ray tube, unless otherwise specified.
94.
"Tube housing assembly" means the tube housing with tube installed. It includes high-voltage
or filament transformers, or both, and other appropriate elements when such are contained
within the tube housing.
95.
"Unrestricted area" means an area, access to which is neither limited nor controlled by the
licensee or registrant.
96.
"Useful beam" means the radiation emanating from the tube housing port or the radiation head
and passing through the aperture of the beam-limiting device when the exposure controls are
in a mode to cause the system to produce radiation.
97.
"Virtual source" means a point from which radiation appears to originate.
98.
"Wedge filter" means an added filter effecting continuous progressive attenuation on all or a
part of the useful beam.
99.
"X-ray tube" means any electron tube which is designed for conversion of electrical energy
into x-ray energy.