NDAC 33.1-14-11-07
Hobby boiler operation
Cite as N.D. Admin. Code ยง 33.1-14-11-07
1.
Notwithstanding any other provision of this section and with the exception of the operation of
miniature boilers, two licensed operators or a licensed operator and an apprentice operator
must be in attendance on a hobby boiler during a parade or plowing demonstration or during
belt operation. At least one licensed operator must be in attendance on a hobby boiler at all
other times except when it is considered safe for a hobby boiler operator to leave the hobby
boiler as described in subsection 2.
2.
A hobby boiler operator is required to be in attendance on a hobby boiler any time the steam
pressure is above fifteen pounds per square inch [103.42 kilopascals] gauge and rising unless
all of the following conditions are met:
a.
The water is above the one-third level in the gauge glass;
b.
The fire is extinguished or banked;
c.
All draft doors are closed;
d.
The main steam outlet valve or dome valve is closed; and
e.
The boiler pressure is at least twenty pounds per square inch [137.90 kilopascals] gauge
below the safety valve set pressure and the boiler pressure is decreasing.