NDAC 33.1-18-02-05
Borehole and well locations
Cite as N.D. Admin. Code ยง 33.1-18-02-05
1.
Prior to the initiation of assessment activities in response to a contaminant release or when
prior departmental approval is required, under existing state statute boreholes and monitoring
wells must be installed at practicable locations based on plans and specifications approved by
the department.
2.
The riser of a monitoring well must terminate at least one foot [0.304 meter] above the ground
surface, except:
a.
Monitoring wells should not be located in drainage ditches, floodplains, or floodway.
Where this is impractical, the monitoring well should terminate at least two feet [0.609
meter] above the one hundred-year flood elevation for the well site. Those risers that do
not must be constructed to preclude flood impact to the monitoring well.
b.
A riser for a well constructed in a high-traffic area or other limiting site conditions should
be mounted flush to grade or below grade with a protective casing to minimize damage,
provided that construction must include a watertight seal to preclude surface water from
entering the protective casing or riser and that the well is clearly marked as a monitoring
well.